Searcharxiv⌕ Search

arXiv subjects

J. Liu

Publications and source records attributed to J. Liu.

At least 73 records · Page 4Linked to original sources

Measurements of a LYSO crystal array from threshold to 100 MeV

We report measurements of ten custom-made high-homogeneity LYSO crystals. The investigation is motivated by the need for a compact, high-resolution, and fast electromagnetic calorimeter for a new rare pion decay experiment. Each $2.5\times 2.5 \times 18$ cm$^3$ crystal was first characterized for general light yield properties and then its longitudinal response uniformity and energy resolution were measured using low-energy gamma sources. The ten crystals were assembled as an array and subjected to a 30 - 100 MeV positron beam with excellent momentum definition. The energy and timing resolutions were measured as a function of energy, and the spatial resolution was determined at 70 MeV. An additional measurement using monoenergetic 17.6 MeV gammas produced through a p-Li resonance was later made after the photosensors used in positron testing were improved. As an example of the results, the energy resolution at 70 MeV of 1.52 $\pm$ 0.03% is more than two times better than reported results using previous generation LYSO crystals.

physics.ins-det↗

PICOSEC Micromegas Precise-timing Detectors: Development towards Large-Area and Integration

PICOSEC Micromegas (MM) is a precise timing gaseous detector based on a Cherenkov radiator coupled with a semi-transparent photocathode and an MM amplifying structure. The detector conceprt was successfully demonstrated through a single-channel prototype, achieving sub-25 ps time resolution with Minimum Ionizing Particles (MIPs). A series of studies followed, aimed at developing robust, large-area, and scalable detectors with high time resolution, complemented by specialized fast-response readout electronics. This work presents recent advancements towards large-area resistive PICOSEC MM, including 10 $\times$ 10 $\text{cm}^2$ area prototypes and a 20 $\times$ 20 $\text{cm}^2$ prototype, which features the jointing of four photocathodes. The time resolution of these detector prototypes was tested during the test beam, achieved a timing performance of around 25 ps for individual pads in MIPs. Meanwhile, customized electronics have been developed dedicated to the high-precision time measurement of the large-area PICOSEC MM. The performance of the entire system was evaluated during the test beam, demonstrating its capability for large-area integration. These advancements highlight the potential of PICOSEC MM to meet the stringent requirements of future particle physics experiments.

physics.ins-det↗

Hadronic cross section measurements with the DAMPE space mission using 20GeV-10TeV cosmic-ray protons and $^4$He

Precise direct cosmic-ray (CR) measurements provide an important probe to study the energetic particle sources in our Galaxy, and the interstellar environment through which these particles propagate. Uncertainties on hadronic models, ion-nucleon cross sections in particular, are currently the limiting factor towards obtaining more accurate CR ion flux measurements with calorimetric space-based experiments. We present an energy-dependent measurement of the inelastic cross section of protons and helium-4 nuclei (alpha particles) on a Bi$_4$Ge$_3$O$_{12}$ target, using 88 months of data collected by the DAMPE space mission. The kinetic energy range per nucleon of the measurement points ranges from 18 GeV to 9 TeV for protons, and from 5 GeV/n to 3 TeV/n for helium-4 nuclei. Our results lead to a significant improvement of the CR flux normalisation. In the case of helium-4, these results correspond to the first cross section measurements on a heavy target material at energies above 10 GeV/n.

hep-ex↗

The optimal structure of the MRPC detector for 0.511 MeV gamma based on Monte Carlo simulation

The detailed simulation of the Multi-gap Resistive Plate Chambers (MRPCs) provides the performance characteristics of MRPCs with different numbers of gas gaps and gap thicknesses. This helps in optimizing the structure of MRPCs under specific conditions by balancing time resolution, detection efficiency, and other performance metrics. To obtain the optimal structure of MRPCs for 0.511 MeV gammas, a complete simulation framework for gamma detection by the MRPCs based on Geant4 and Magboltz software is described in this paper. The simulation shows how gammas interact with MRPCs and the process of gas ionization, avalanche multiplication, and signal formation. The simulation results are in good agreement with the experimental results. By analyzing the time resolution and detection efficiency, the optimal structure of MRPCs for 0.511 MeV gammas is proposed.

physics.ins-det↗

Observation of a spectral hardening in cosmic ray boron spectrum with the DAMPE space mission

Secondary cosmic ray fluxes are important probes of the propagation and interaction of high-energy particles in the Galaxy. Recent measurements of primary and secondary cosmic ray nuclei have revealed unexpected spectral features that demand a deeper understanding. In this work we report the direct measurement of the cosmic ray boron spectrum from 10 GeV/n to 8 TeV/n with eight years of data collected by the Dark Matter Particle Explorer (DAMPE) mission. The measured spectrum shows an evident hardening at $182\pm24$ GeV/n with a spectral power index of $γ_1 = 3.02 \pm 0.01$ before the break and an index change of $Δγ= 0.31 \pm 0.05$ after the break. A simple power law model is disfavored at a confidence level of 8$σ$. Compared with the hardenings measured in the DAMPE proton and helium spectra, the secondary boron spectrum hardens roughly twice as much as these primaries, which is consistent with a propagation related mechanism to interpret the spectral hardenings of cosmic rays observed at hundreds of GeV/n.

astro-ph.HE↗

Photocathode characterisation for robust PICOSEC Micromegas precise-timing detectors

The PICOSEC Micromegas detector is a~precise-timing gaseous detector based on a~Cherenkov radiator coupled with a~semi-transparent photocathode and a~Micromegas amplifying structure, targeting a~time resolution of tens of picoseconds for minimum ionising particles. Initial single-pad prototypes have demonstrated a~time resolution below 25 ps, prompting ongoing developments to adapt the concept for High Energy Physics applications, where sub-nanosecond precision is essential for event separation, improved track reconstruction and particle identification. The achieved performance is being transferred to robust multi-channel detector modules suitable for large-area detection systems requiring excellent timing precision. To enhance the robustness and stability of the PICOSEC Micromegas detector, research on robust carbon-based photocathodes, including Diamond-Like Carbon (DLC) and Boron Carbide (B4C), is pursued. Results from prototypes equipped with DLC and B4C photocathodes exhibited a~time resolution of approximately 32 ps and 34.5 ps, respectively. Efforts dedicated to improve detector robustness and stability enhance the feasibility of the PICOSEC Micromegas concept for large experiments, ensuring sustained performance while maintaining excellent timing precision.

physics.ins-det↗

YSO implantation detector for beta-delayed neutron spectroscopy

A segmented-scintillator-based implantation detector was developed to study the energy distribution of beta-delayed neutrons emitted from exotic isotopes. The detector comprises a 34 $\times$ 34 YSO scintillator coupled to an 8 $\times$ 8 Position-Sensitive Photo-Multiplier Tube (PSPMT) via a tapered light guide. The detector was used at RIBF, RIKEN, for time-of-flight-based neutron spectroscopy measurement in the $^{78}$Ni region. The detector provides the position and timing resolution necessary for ion-beta correlations and ToF measurements. The detector provides a high $\sim$ 80 $\%$ beta-detection efficiency and a sub-nanosecond timing resolution. This contribution discusses the details of the design, operation, implementation, and analysis developed to obtain neutron time-of-flight spectrum and the analysis methods in the context of neutron-rich nuclei in the $^{78}$Ni region.

physics.ins-det↗

Search for $CP$-Violating Neutrino Nonstandard Interactions with the NOvA Experiment

This Letter reports a search for charge-parity ($CP$) symmetry violating nonstandard interactions (NSI) of neutrinos with matter using the NOvA Experiment, and examines their effects on the determination of the standard oscillation parameters. Data from $ν_μ(\barν_μ)\rightarrowν_μ(\barν_μ)$ and $ν_μ(\barν_μ)\rightarrowν_{e}(\barν_{e})$ oscillation channels are used to measure the effect of the NSI parameters $\varepsilon_{eμ}$ and $\varepsilon_{eτ}$. With 90% CL the magnitudes of the NSI couplings are constrained to be $|\varepsilon_{eμ}| \, \lesssim 0.3$ and $|\varepsilon_{eτ}| \, \lesssim 0.4$. A degeneracy at $|\varepsilon_{eτ}| \, \approx 1.8$ is reported, and we observe that the presence of NSI limits sensitivity to the standard $CP$ phase $δ_{\tiny\text{CP}}$.

hep-ex↗

Measurement of the double-differential cross section of muon-neutrino charged-current interactions with low hadronic energy in the NOvA Near Detector

The NOvA collaboration reports cross-section measurements for $ν_μ$ charged-current interactions with low hadronic energy (maximum kinetic energy of 250 MeV for protons and 175 MeV for pions) in the NOvA Near Detector. The results are presented as a double-differential cross section as a function of the direct observables of the final-state muon kinematics. Results are also presented as a single-differential cross section as a function of the derived square of the four-momentum transfer, $Q^{2}$, and as a function of the derived neutrino energy. The data correspond to an accumulated 8.09$\times10^{20}$ protons-on-target (POT) in the neutrino mode of the NuMI beam, with a narrow band of neutrino energies peaked at 1.8 GeV. The analysis provides a sample of neutrino-nucleus interactions with an enhanced fraction of quasi-elastic and two-particle-two-hole (2p2h) interactions. This enhancement allows quantitative comparisons with various nuclear models. We find strong disagreement between data and theory-based models in various regions of the muon kinematic phase space, especially in the forward muon direction.

hep-ex↗

Longitudinal and transverse mobilities of $n$-type monolayer transition metal dichalcogenides in the presence of proximity-induced interactions at low temperature

We present a detailed theoretical investigation on the electronic transport properties of $n$-type monolayer (ML) transition metal dichalcogenides (TMDs) at low temperature in the presence of proximity-induced interactions such as Rashba spin-orbit coupling (RSOC) and the exchange interaction. The electronic band structure is calculated by solving the Schrödinger equation with a $\mathbf{k}\cdot\mathbf{p}$ Hamiltonian, and the electric screening induced by electron-electron interaction is evaluated under a standard random phase approximation approach. In particular, the longitudinal and transverse or Hall mobilities are calculated by using a momentum-balance equation derived from a semi-classical Boltzmann equation, where the electron-impurity interaction is considered as the principal scattering center at low temperature. The obtained results show that the RSOC can induce the in-plane spin components for spin-split subbands in different valleys, while the exchange interaction can lift the energy degeneracy for electrons in different valleys. The opposite signs of Berry curvatures in the two valleys would introduce opposite directions of Lorentz force on valley electrons. As a result, the transverse currents from nondegenerate valleys can no longer be canceled out so that the transverse current or Hall mobility can be observed. Interestingly, we find that at a fixed effective Zeeman field, the lowest spin-split conduction subband in ML-TMDs can be tuned from one in the $K'$-valley to one in the $K$-valley by varying the Rashba parameter. The occupation of electrons in different valleys also varies with changing carrier density. Therefore, we can change the magnitude and direction of the Hall current by varying the Rashba parameter, effective Zeeman field, and carrier density by, e.g., the presence of a ferromagnetic substrate and/or applying a gate voltage.

cond-mat.mes-hall↗

Isospin breaking in the $^{71}$Kr and $^{71}$Br mirror system

Isospin symmetry is a fundamental concept in nuclear physics. Even though isospin symmetry is partially broken, it holds approximately for most nuclear systems, which makes exceptions very interesting from the nuclear structure perspective. In this framework, it is expected that the spins and parities of the ground states of mirror nuclei should be the same, in particular for the simplest systems where a proton is exchanged with a neutron or vice versa. In this work, we present evidence that this assumption is broken in the mirror pair $^{71}$Br and $^{71}$Kr system. Our conclusions are based on a high-statistics $β$ decay study of $^{71}$Kr and on state-of-the-art shell model calculations. In our work, we also found evidence of a new state in $^{70}$Se, populated in the $β$-delayed proton emission process which can be interpreted as the long sought coexisting 0$^+$ state.

nucl-ex↗

PICOSEC-Micromegas Detector, an innovative solution for Lepton Time Tagging

The PICOSEC-Micromegas (PICOSEC-MM) detector is a novel gaseous detector designed for precise timing resolution in experimental measurements. It eliminates time jitter from charged particles in ionization gaps by using extreme UV Cherenkov light emitted in a crystal, detected by a Micromegas photodetector with an appropriate photocathode. The first single-channel prototype tested in 150 GeV/c muon beams achieved a timing resolution below 25 ps, a significant improvement compared to standard Micropattern Gaseous Detectors (MPGDs). This work explores the specifications for applying these detectors in monitored neutrino beams for the ENUBET Project. Key aspects include exploring resistive technologies, resilient photocathodes, and scalable electronics. New 7-pad resistive detectors are designed to handle the particle flux. In this paper, two potential scenarios are briefly considered: tagging electromagnetic showers with a timing resolution below 30 ps in an electromagnetic calorimeter as well as individual particles (mainly muons) with about 20 ps respectively.

physics.ins-det↗

A global colour mosaic of Mars from Mars Express HRSC high altitude observations

The ever-changing transparency of the Martian atmosphere hinders the determination of absolute surface colour from spacecraft images. While individual high-resolution images from low orbit reveal numerous colour details of the geology, the colour variation between images caused by scattering off atmospheric dust can easily be of greater magnitude. The construction of contiguous large-scale mosaics has thus required a strategy to suppress the influence of scattering, often a form of high-pass filtering, which limits their ability to convey colour variation information over distances greater than the dimensions of single images. Here we use a dedicated high altitude observation campaign with the Mars Express High Resolution Stereo Camera (HRSC) (Neukum and Jaumann, 2004; Jaumann et al., 2007), applying a novel iterative method to construct a globally self-consistent colour model. We apply the model to colour-reference a high-altitude mosaic incor-porating long-range colour variation information. Using only the relative colour information internal to individual images, the influence of absolute image to image colour changes caused by scattering is minimised, while the model enables col-our variations across image boundaries to be self-consistently reconstructed. The resulting mosaic shows a level of colour detail comparable to single images, while maintaining continuity of colour features over much greater distances, thereby increasing the utility of HRSC colour images in the tracing and analysis of martian surface structures.

astro-ph.EP↗

A Multi-station Meteor Monitoring (M$^3$) System. II. system upgrade and a pathfinder network

Meteors are important phenomenon reflecting many properties of interplanetary dust particles. The study of their origin, mass distribution, and orbit evolution all require large data volume, which can only be obtained using large meteor networks. After meteor networks in Europe and America, we present our designs and upgrades of a proposing network in China. The new designs are mainly aimed for facilitating data gathering process. Each of the newly designed meteor stations now can support up to 4 cameras to cover the full sky. Newer version of meteor station software now works as an integral system, which can streamline the process of detecting, measuring and uploading meteors. We have built a meteor data platform to store, process and display the meteor data automatically. The software and data platform are designed to be easy to learn and use, so it can attract more people to join and operate meteor stations. Four stations are installed as the first phase of the network, and during the operation in 10 months, the network detected 8,683 orbits, and we find that half of the orbits can be related to established meteoroid streams. The statistical analysis of sporadic meteoroids shows a bimodal distribution of the velocities, which coincides with previous studies. The distribution of Tisserand parameters, $T_j$, shows the two peaks at $T_j=0$ and 3, indicating the different orbits of parent bodies (isotropic and ecliptic), which are divided by $T_j=2$. The falling trajectory of a meteorite was also predicted using observational data of the network. We are currently expanding the network, and in the future we will carry out detailed analysis of the key parameters of the distribution of the meteoroids.

astro-ph.IM↗

High Performance Operation of a Direct-Current and Superconducting Radio-Frequency Combined Photocathode Gun

Superconducting radio-frequency (SRF) guns are promising candidates to deliver high brightness continuous-wave (CW) electron beams for new generations of coherent linac light sources, ultrafast electron diffractions, MeV pulsed beam applications, etc. To solve the compatibility problem of semiconductor photocathodes, a hybrid gun combining a direct-current gap and an SRF cavity has been developed. The gun, employing K2CsSb photocathodes driven by a green laser, has been brought into stable CW operation with a dark current below 100 pA, delivering electron beams at an energy gain of 2.4 MeV, an electron bunch charge of 100 pC, and a repetition rate of 1 MHz. A normalized beam emittance of 0.54 mm-mrad has been achieved at the bunch charge of 100 pC and peak current of about 6 A. CW operation at 81.25 MHz repetition rate has also been tested with the maximum average beam current reaching 3 mA.

physics.acc-ph↗

A Multi-station Meteor Monitoring (M$^3$) System. I. Design and Testing

Meteors carry important and indispensable information about the interplanetary environment, which can be used to understand the origin and evolution of our solar system. We have developed a Multi-station Meteor Monitoring ($\rm M^3$) system that can observe almost the entire sky and detect meteors automatically, and it determines their trajectories. They are highly extensible to construct a large-scale network. Each station consists of a waterproof casing, a wide field-of-view lens with a CMOS camera, and a supporting computer. The camera has a built-in GPS module for accurately timing the meteoroid entry into the atmosphere (accurate to 1 $μ$s), which is the most prominent characteristic compared with other existing meteor monitoring devices. We have also developed a software package that can efficiently identify and measure meteors appearing in the real-time video stream and compute the orbits of meteoroids in the solar system via multi-station observations. During the Geminid meteor shower in 2021, the M$^3$ system was tested at two stations ($\sim$55 km apart) in the suburbs of Beijing. The test results show that the astrometric accuracy is about 0.3-0.4 arcmin. About 800 meteors were detected by these two stations. A total of 473 meteors have their orbits calculated by our software, and 377 of them belong to the Geminid meteoroid stream. Our M$^3$ system will be further tested and upgraded, and it will be used to construct a large monitoring network in China in the future.

astro-ph.IM↗

Light Dark Matter Constraints from SuperCDMS HVeV Detectors Operated Underground with an Anticoincidence Event Selection

This article presents constraints on dark-matter-electron interactions obtained from the first underground data-taking campaign with multiple SuperCDMS HVeV detectors operated in the same housing. An exposure of 7.63 g-days is used to set upper limits on the dark-matter-electron scattering cross section for dark matter masses between 0.5 and 1000 MeV/$c^2$, as well as upper limits on dark photon kinetic mixing and axion-like particle axioelectric coupling for masses between 1.2 and 23.3 eV/$c^2$. Compared to an earlier HVeV search, sensitivity was improved as a result of an increased overburden of 225 meters of water equivalent, an anticoincidence event selection, and better pile-up rejection. In the case of dark-matter-electron scattering via a heavy mediator, an improvement by up to a factor of 25 in cross-section sensitivity was achieved.

hep-ex↗

Measurement of the cosmic p+He energy spectrum from 50 GeV to 0.5 PeV with the DAMPE space mission

Recent observations of the light component of the cosmic-ray spectrum have revealed unexpected features that motivate further and more precise measurements up to the highest energies. The Dark Matter Particle Explorer is a satellite-based cosmic-ray experiment that has been operational since December 2015, continuously collecting data on high-energy cosmic particles with very good statistics, energy resolution, and particle identification capabilities. In this work, the latest measurements of the energy spectrum of proton+helium in the energy range from 46 GeV to 464 TeV are presented. Among the most distinctive features of the spectrum, a spectral hardening at 600 GeV has been observed, along with a softening at 29 TeV measured with a 6.6σ significance. Moreover, the detector features and the analysis approach allowed for the extension of the spectral measurement up to the sub-PeV region. Even if with small statistical significance due to the low number of events, data suggest a new spectral hardening at about 150 TeV.

astro-ph.HE↗