SearcharxivSearch

arXiv subjects

J. M. Cela

Publications and source records attributed to J. M. Cela.

4 recordsLinked to original sources

The Double Chooz antineutrino detectors

This article describes the setup and performance of the near and far detectors in the Double Chooz experiment. The electron antineutrinos of the Chooz nuclear power plant were measured in two identically designed detectors with different average baselines of about 400 m and 1050 m from the two reactor cores. Over many years of data taking the neutrino signals were extracted from interactions in the detectors with the goal of measuring a fundamental parameter in the context of neutrino oscillation, the mixing angle θ13. The central part of the Double Chooz detectors was a main detector comprising four cylindrical volumes filled with organic liquids. From the inside towards the outside there were volumes containing gadolinium-loaded scintillator, gadolinium-free scintillator, a buffer oil and, optically separated, another liquid scintillator acting as veto system. Above this main detector an additional outer veto system using plastic scintillator strips was installed. The technologies developed in Double Chooz were inspiration for several other antineutrino detectors in the field. The detector design allowed implementation of efficient background rejection techniques including use of pulse shape information provided by the data acquisition system. The Double Chooz detectors featured remarkable stability, in particular for the detected photons, as well as high radiopurity of the detector components.

physics.ins-det

Mechanical Ventilator Milano (MVM): A Novel Mechanical Ventilator Designed for Mass Scale Production in Response to the COVID-19 Pandemic

Presented here is the design of the Mechanical Ventilator Milano (MVM), a novel mechanical ventilator designed for rapid mass production in response to the COVID-19 pandemic to address the urgent shortage of intensive therapy ventilators in many countries, and the growing difficulty in procuring these devices through normal supply chains across borders. This ventilator is an electro-mechanical equivalent of the old and reliable Manley Ventilator, and is able to operate in both pressure-controlled and pressure-supported ventilation modes. MVM is optimized for the COVID-19 emergency, thanks to the collaboration with medical doctors in the front line. MVM is designed for large-scale production in a short amount of time and at a limited cost, as it relays on off-the-shelf components, readily available worldwide. Operation of the MVM requires only a source of compressed oxygen (or compressed medical air) and electrical power. Initial tests of a prototype device with a breathing simulator are also presented. Further tests and developments are underway. At this stage the MVM is not yet a certified medical device but certification is in progress.

physics.med-ph

AVOLAR. A high voltage generator for liquid argon time projection chambers

Some of the main neutrino oscillation and dark matter experiments have chosen time projection chambers (TPC) filled with liquid argon (LAr) as their technology for the next generation of detectors. Because of its typical drift length of several meters, relatively large cathode voltages are desirable to provide a sizeable drift field. Current designs are based on feedthroughs with high voltages (HV) limited to several hundred kV. The present work proposes a novel method to produce higher voltages inside the detector. It is based on a Van de Graaff HV generator where the charge transporting belt is replaced by a cryogenic LAr flow. Negative charge is injected in liquid by means of a grounded sharp point facing a positive voltage electrode with a high speed LAr stream in between. The LAr flow transports the charge to the cathode through an electrically insulating pipe. In the cathode the charge is extracted with a metallic mesh. The LAr flux is driven by a cryogenic helium pump with unidirectional valves assuring a continuous flow. The LAr operational temperature is maintained by a pressurized liquid nitrogen deposit with automatic filling. The whole system is installed within a dewar container that will be filled with LAr reproducing the typical TPC conditions. This design has no mobile parts, so it is very robust and can be easily embedded within the structural support of a TPC cathode. A prototype of this HV generator has been constructed at CIEMAT (Madrid), and is currently being characterized. This R&D is presented and the preliminary results are discussed.

physics.ins-det

Stability of three-dimensional relativistic jets: implications for jet collimation

The stable propagation of jets in FRII sources is remarkable if one takes into account that large-scale jets are subjected to potentially highly disruptive three-dimensional (3D) Kelvin-Helmholtz instabilities. Numerical simulations can address this problem and help clarify the causes of this remarkable stability. Following previous studies of the stability of relativistic flows in two dimensions (2D), it is our aim to test and extend the conclusions of such works to three dimensions. We present numerical simulations for the study of the stability properties of 3D, sheared, relativistic flows. This work uses a fully parallelized code Ratpenat that solves equations of relativistic hydrodynamics in 3D. The results of the present simulations confirm those in 2D. We conclude that the growth of resonant modes in sheared relativistic flows could be important in explaining the long-term collimation of extragalactic jets.

astro-ph.HE