SearcharxivSearch

arXiv subjects

J. M. Hogan

Publications and source records attributed to J. M. Hogan.

5 recordsLinked to original sources

Standard Model Physics at the HL-LHC and HE-LHC

The successful operation of the Large Hadron Collider (LHC) and the excellent performance of the ATLAS, CMS, LHCb and ALICE detectors in Run-1 and Run-2 with $pp$ collisions at center-of-mass energies of 7, 8 and 13 TeV as well as the giant leap in precision calculations and modeling of fundamental interactions at hadron colliders have allowed an extraordinary breadth of physics studies including precision measurements of a variety physics processes. The LHC results have so far confirmed the validity of the Standard Model of particle physics up to unprecedented energy scales and with great precision in the sectors of strong and electroweak interactions as well as flavour physics, for instance in top quark physics. The upgrade of the LHC to a High Luminosity phase (HL-LHC) at 14 TeV center-of-mass energy with 3 ab$^{-1}$ of integrated luminosity will probe the Standard Model with even greater precision and will extend the sensitivity to possible anomalies in the Standard Model, thanks to a ten-fold larger data set, upgraded detectors and expected improvements in the theoretical understanding. This document summarises the physics reach of the HL-LHC in the realm of strong and electroweak interactions and top quark physics, and provides a glimpse of the potential of a possible further upgrade of the LHC to a 27 TeV $pp$ collider, the High-Energy LHC (HE-LHC), assumed to accumulate an integrated luminosity of 15 ab$^{-1}$.

hep-ph

SAGE: A Proposal for a Space Atomic Gravity Explorer

The proposed mission "Space Atomic Gravity Explorer" (SAGE) has the scientific objective to investigate gravitational waves, dark matter, and other fundamental aspects of gravity as well as the connection between gravitational physics and quantum physics using new quantum sensors, namely, optical atomic clocks and atom interferometers based on ultracold strontium atoms.

astro-ph.IM

Response to "Verifying quantum superpositions at metre scales"

The preceding BCA (Stamper-Kurn et. al., arXiv:1607.01454) asserts that our observation of interference contrast in a half-metre-scale atom interferometer (Kovachy et. al., Nature 528, 530-3 (2015)) does not prove the existence of macroscopic quantum superpositions and hence does not test quantum mechanics at long length scales. Moreover, the BCA implies that intrinsic atomic interactions or technical imperfections could prevent the application of our work to future differential measurements. On the contrary, we argue the following: i) in standard quantum mechanics, there is no known mechanism in our system that prohibits its use in future differential measurement applications; ii) our experiment tests quantum mechanics in that it constrains any modifications that would reduce contrast in an interferometer with arms that propagate over widely separated trajectories; and iii) using a standard definition of superposition, our observation of interference results from quantum superposition at the half-metre scale. In particular, quantum superposition is a more general concept than first-order coherence.

quant-ph

A Precision Angle Sensor using an Optical Lever inside a Sagnac Interferometer

We built an ultra low noise angle sensor by combining a folded optical lever and a Sagnac interferometer. The instrument has a measured noise floor of 1.3 prad / Hz^(1/2) at 2.4 kHz. We achieve this record angle sensitivity using a proof-of-concept apparatus with a conservative N=11 bounces in the optical lever. This technique could be extended to reach sub-picoradian / Hz^(1/2) sensitivities with an optimized design.

physics.optics

Broadband Optical Serrodyne Frequency Shifting

We demonstrate serrodyne frequency shifting of light from 200 MHz to 1.2 GHz with an efficiency of better than 60 percent. The frequency shift is imparted by an electro-optic phase modulator driven by a high-frequency, high-fidelity sawtooth waveform that is passively generated by a commercially available Non-Linear Transmission Line (NLTL). We also implement a push-pull configuration using two serrodyne-driven phase modulators allowing for continuous tuning between -1.6 GHz and +1.6 GHz. Compared to competing technologies, this technique is simple and robust, and offers the largest available tuning range in this frequency band.

physics.optics