Searcharxiv⌕ Search

arXiv subjects

J. M. R. Teixeira

Publications and source records attributed to J. M. R. Teixeira.

11 recordsLinked to original sources

Demonstrating topological identification capabilities of the NEXT experiment at low pressure

The NEXT-100 detector is a high-pressure xenon time projection chamber utilising electroluminescence amplification for sub-1% FWHM energy resolution and topological discrimination, two key attributes required to achieve the NEXT programme's overarching goal of detecting neutrinoless double beta decay ($0 νββ$). The detector has completed its first physics run at the Laboratorio Subterráneo de Canfranc (LSC), with xenon at a pressure of $\sim$4 bar. In this paper we report on the first validation of NEXT-100's topological performance and present the first topological analysis conducted at low pressure within the detector programme. A Monte Carlo study characterising the effects of pressure on track topology is presented, with qualitative agreement observed in data. We then demonstrate the topological discrimination capabilities for $0νββ$-like events from $^{208}$Tl decays using a cut-based method considered the 'baseline' in NEXT's topological programme, upon which all future analyses will improve. The analysis described applies a set of selection cuts before implementing a background discrimination algorithm that yields a reported signal efficiency for double-electron tracks and background acceptance for single-electron tracks of 75.6 $\pm$ 1.9 (stat.) $^{+3.4}_{-4.1}$ (syst.) % and 14.7 $\pm$ 0.4 (stat.) $^{+0.7}_{-0.8}$ (syst.) %. These results demonstrate the excellent topological discrimination capabilities of the NEXT-100 detector in line with NEXT-White, which achieved a signal efficiency and background acceptance of 71.6 $\pm$ 1.5 (stat.) $\pm$ 0.3 (syst.) % and 20.6 $\pm$ 0.4 (stat.) $\pm$ 0.3 (syst.) % respectively.

hep-ex↗

Radon-induced backgrounds in the NEXT-100 experiment

The NEXT-100 detector at the LSC aims at the first competitive search for the \bbnonu decay using a high-pressure \Xe{136} electroluminescent time projection chamber. The first low-background run of NEXT-100 at 3.95 bar has been devoted to the measurement of the radon-induced backgrounds impacting this search. The contributions from both the internal and external airborne radon have been evaluated. The internal \Rn{222} activity is found to be (0.95$\pm$0.04(stat)$\pm$0.09(sys)) Bq/m$^3$, while no traces of \Rn{220} have been observed. Most of the \Rn{222} progeny plate-out on the surface of the cathode of the detector, leading to a rate of Rn-induced \Bi{214} of (0.97$\pm$0.05(stat)$\pm$0.10(sys)) Hz for visible energies above 400 keV. The corresponding background index in the \bbnonu region of interest is evaluated as (7.3$\pm$1.5(stat)$\pm$0.8(sys))$\times10^{-4}$ counts/(keV$\cdot$kg$\cdot$yr) after selection of the fully contained events. This background index is reduced to $\sim$4$\times10^{-5}$ counts/(keV$\cdot$kg$\cdot$yr) by applying a topological selection requiring only one double-electron-like track in the events. This value is one order of magnitude below the total radiogenic background expectation in NEXT-100. By analyzing the correlation of the airborne radon activity and the measured rate of events in NEXT-100, it is concluded that the detector operates in a virtually radon-free environment thanks to the radon abatement system of the LSC.

hep-ex↗

High Voltage Delivery and Distribution for the NEXT-100 Time Projection Chamber

A critical element in the realization of large liquid and gas time projection chambers (TPCs) is the delivery and distribution of high voltages into and around the detector. Such experiments require of order tens of kilovolts to enable electron drift over meter-scale distances. This paper describes the design and operation of the cathode feedthrough and high voltage distribution through the field cage of the NEXT-100 experiment, an underground TPC that will search for neutrinoless double beta decay $0νββ$. The feedthrough has been demonstrated to hold pressures up to 20~bar and sustain voltages as high as -65~kV, and the TPC is operating stably at its design high voltages. The system has been realized within the constraints of a stringent radiopurity budget and is now being used to execute a suite of sensitive double beta decay analyses.

physics.ins-det↗

Reconstructing neutrinoless double beta decay event kinematics in a xenon gas detector with vertex tagging

If neutrinoless double beta decay is discovered, the next natural step would be understanding the lepton number violating physics responsible for it. Several alternatives exist beyond the exchange of light neutrinos. Some of these mechanisms can be distinguished by measuring phase-space observables, namely the opening angle $\cosθ$ among the two decay electrons, and the electron energy spectra, $T_1$ and $T_2$. In this work, we study the statistical accuracy and precision in measuring these kinematic observables in a future xenon gas detector with the added capability to precisely locate the decay vertex. For realistic detector conditions (a gas pressure of 10 bar and spatial resolution of 4 mm), we find that the average $\overline{\cosθ}$ and $\overline{T_1}$ values can be reconstructed with a precision of 0.19 and 110 keV, respectively, assuming that only 10 neutrinoless double beta decay events are detected.

hep-ex↗

Efficient noble gas purification using hot getters and gas circulation by convection

Noble gas radiation detectors with optical readout are gaining popularity in fields like astrophysics and particle physics due to their ability to produce both ionization and scintillation signals in response to ionizing radiation interaction. In addition, the amplification of primary ionization signals can be achieved by promoting secondary scintillation in the gas. Noble gas purity, especially concerning impurities like H$_{2}$O, N$_{2}$, O$_{2}$, CO$_{2}$, and hydrocarbons, greatly influences its performance. These impurities can cause the loss of primary electrons and quench the scintillation signal. A very high purity level of the gas is required. In the early 90's, a simple method was developed for noble gas purification in sealed, small volume (up to few litters) gas radiation detectors. Gas purification is achieved promoting gas circulation through Zr-based hot getters, simply maintaining the gas circulation by convection. The effectiveness of this method has been only confirmed by the energy resolutions achieved in those detectors, which were similar to that achieved in other high-performance noble gas detectors. In this work, we used waveform analysis of the primary and secondary scintillation signals and we were able to evaluate the impact of the attachment and quenching caused by impurities in one of our detectors filled with pure Xe, and estimate upper values for the impurity content in the gas. The maximum overall impurity concentration was estimated to be below 4 ppm, considering nearly all the impurities, and below 82 ppm if N$_{2}$ is considered. The electron lifetime was measured to be 2.1 $\pm$ 0.1 ms, in line with those achieved in other high-performance optical detectors.

physics.ins-det↗

Measurement of Energy Resolution with the NEXT-White Silicon Photomultipliers

The NEXT-White detector, a high-pressure gaseous xenon time projection chamber, demonstrated the excellence of this technology for future neutrinoless double beta decay searches using photomultiplier tubes (PMTs) to measure energy and silicon photomultipliers (SiPMs) to extract topology information. This analysis uses $^{83m}\text{Kr}$ data from the NEXT-White detector to measure and understand the energy resolution that can be obtained with the SiPMs, rather than with PMTs. The energy resolution obtained of (10.9 $\pm$ 0.6) $\%$, full-width half-maximum, is slightly larger than predicted based on the photon statistics resulting from very low light detection coverage of the SiPM plane in the NEXT-White detector. The difference in the predicted and measured resolution is attributed to poor corrections, which are expected to be improved with larger statistics. Furthermore, the noise of the SiPMs is shown to not be a dominant factor in the energy resolution and may be negligible when noise subtraction is applied appropriately, for high-energy events or larger SiPM coverage detectors. These results, which are extrapolated to estimate the response of large coverage SiPM planes, are promising for the development of future, SiPM-only, readout planes that can offer imaging and achieve similar energy resolution to that previously demonstrated with PMTs.

hep-ex↗

Unraveling xenon primary scintillation yield for cutting-edge rare event experiments

Xenon scintillation has been widely used in rare event detection experiments such as neutrinoless double beta decay, double electron captures and dark matter searches. Nonetheless, experimental values for primary scintillation yield in gaseous xenon (GXe) remain scarce and dispersed. The mean energy required to produce a scintillation photon, wsc, in GXe in the absence of recombination has been measured to be in the range of 34-111 eV. Lower values were reported for alpha-particles when compared to electrons produced by gamma- or x-rays. Since wsc is expected to be similar for x-, gamma-rays or electrons and alpha-particles, the above difference cannot be understood. In addition, one may pose the question of a dependence of wsc on photon energy. We carried out a systematic study on the absolute primary scintillation yield in GXe for electric fields in the 70-300 V/cm/bar range and for 1.2 bar supported by a robust geometrical efficiency simulation model. We were able to clear-out the above standing problems: we determined wsc for x/gamma-rays in the 5.9-60 keV range and alpha-particles in the 1.5-2.5 MeV range; no significant dependency neither on radiation type nor on energy was observed. Our values agree well with both state-of-art simulations and literature data obtained for alpha-particles. The discrepancy between our results and experimental values in the literature for x/gamma-rays is discussed in this work and attributed to unaddressed large systematic errors in previous studies. These findings can be extrapolated to other gases and have impact on experiments such as double beta decay, double electron capture and directional dark matter searches while also on potential future detection systems such as DUNE-Gas. Neglecting the 3rd continuum emission, as is the case of most of the literature values, a mean wsc-value of 38.7 [+- 0.6 (sta.)] [(- 7.2) (+ 7.7) (sys.)] eV was obtained.

astro-ph.IM↗

Reflectance and fluorescence characteristics of PTFE coated with TPB at visible, UV, and VUV as a function of thickness

Polytetrafluoroethylene (PTFE) is an excellent diffuse reflector widely used in light collection systems for particle physics experiments. In noble element systems, it is often coated with tetraphenyl butadiene (TPB) to allow detection of vacuum ultraviolet scintillation light. In this work this dependence is investigated for PTFE coated with TPB in air for light of wavelengths of 200~nm, 260~nm, and 450~nm. The results show that TPB-coated PTFE has a reflectance of approximately 92\% for thicknesses ranging from 5~mm to 10~mm at 450~nm, with negligible variation as a function of thickness within this range. A cross-check of these results using an argon chamber supports the conclusion that the change in thickness from 5~mm to 10~mm does not affect significantly the light response at 128~nm. Our results indicate that pieces of TPB-coated PTFE thinner than the typical 10~mm can be used in particle physics detectors without compromising the light signal.

physics.ins-det↗

Neutral Bremsstrahlung emission in xenon unveiled

We present evidence of non-excimer-based secondary scintillation in gaseous xenon, obtained using both the NEXT-White TPC and a dedicated setup. Detailed comparison with first-principle calculations allows us to assign this scintillation mechanism to neutral bremsstrahlung (NBrS), a process that has been postulated to exist in xenon that has been largely overlooked. For photon emission below 1000 nm, the NBrS yield increases from about 10$^{-2}$ photon/e$^{-}$ cm$^{-1}$ bar$^{-1}$ at pressure-reduced electric field values of 50 V cm$^{-1}$ bar$^{-1}$ to above 3$\times$10$^{-1}$ photon/e$^{-}$ cm$^{-1}$ bar$^{-1}$ at 500 V cm$^{-1}$ bar$^{-1}$. Above 1.5 kV cm$^{-1}$ bar$^{-1}$, values that are typically employed for electroluminescence, it is estimated that NBrS is present with an intensity around 1 photon/e$^{-}$ cm$^{-1}$ bar$^{-1}$, which is about two orders of magnitude lower than conventional, excimer-based electroluminescence. Despite being fainter than its excimeric counterpart, our calculations reveal that NBrS causes luminous backgrounds that can interfere, in either gas or liquid phase, with the ability to distinguish and/or to precisely measure low primary-scintillation signals (S1). In particular, we show this to be the case in the "buffer" and "veto" regions, where keeping the electric field below the electroluminescence (EL) threshold will not suffice to extinguish secondary scintillation. The electric field in these regions should be chosen carefully to avoid intolerable levels of NBrS emission. Furthermore, we show that this new source of light emission opens up a viable path towards obtaining S2 signals for discrimination purposes in future single-phase liquid TPCs for neutrino and dark matter physics, with estimated yields up to 20-50 photons/e$^{-}$ cm$^{-1}$.

physics.ins-det↗

Boosting background suppression in the NEXT experiment through Richardson-Lucy deconvolution

Next-generation neutrinoless double beta decay experiments aim for half-life sensitivities of ~$10^{27}$ yr, requiring suppressing backgrounds to <1 count/tonne/yr. For this, any extra background rejection handle, beyond excellent energy resolution and the use of extremely radiopure materials, is of utmost importance. The NEXT experiment exploits differences in the spatial ionization patterns of double beta decay and single-electron events to discriminate signal from background. While the former display two Bragg peak dense ionization regions at the opposite ends of the track, the latter typically have only one such feature. Thus, comparing the energies at the track extremes provides an additional rejection tool. The unique combination of the topology-based background discrimination and excellent energy resolution (1% FWHM at the Q-value of the decay) is the distinguishing feature of NEXT. Previous studies demonstrated a topological background rejection factor of ~5 when reconstructing electron-positron pairs in the $^{208}$Tl 1.6 MeV double escape peak (with Compton events as background), recorded in the NEXT-White demonstrator at the Laboratorio Subterráneo de Canfranc, with 72% signal efficiency. This was recently improved through the use of a deep convolutional neural network to yield a background rejection factor of ~10 with 65% signal efficiency. Here, we present a new reconstruction method, based on the Richardson-Lucy deconvolution algorithm, which allows reversing the blurring induced by electron diffusion and electroluminescence light production in the NEXT TPC. The new method yields highly refined 3D images of reconstructed events, and, as a result, significantly improves the topological background discrimination. When applied to real-data 1.6 MeV $e^-e^+$ pairs, it leads to a background rejection factor of 27 at 57% signal efficiency.

physics.ins-det↗

Sensitivity of a tonne-scale NEXT detector for neutrinoless double beta decay searches

The Neutrino Experiment with a Xenon TPC (NEXT) searches for the neutrinoless double-beta decay of Xe-136 using high-pressure xenon gas TPCs with electroluminescent amplification. A scaled-up version of this technology with about 1 tonne of enriched xenon could reach in less than 5 years of operation a sensitivity to the half-life of neutrinoless double-beta decay decay better than 1E27 years, improving the current limits by at least one order of magnitude. This prediction is based on a well-understood background model dominated by radiogenic sources. The detector concept presented here represents a first step on a compelling path towards sensitivity to the parameter space defined by the inverted ordering of neutrino masses, and beyond.

physics.ins-det↗