Searcharxiv⌕ Search

arXiv subjects

J. M. St. John

Publications and source records attributed to J. M. St. John.

6 recordsLinked to original sources

First Observation of Antiproton Annihilation At Rest on Argon in the LArIAT Experiment

We report the first observation and measurement of antiproton annihilation at rest on argon using the LArIAT experiment. Antiprotons from a charged particle test beam that come to rest inside LArIAT's liquid argon time projection chamber (LArTPC) are identified through beamline instrumentation and LArTPC track reconstruction algorithms. The multiplicity of charged particle tracks originating from the annihilation vertex is manually assessed through hand-scanning, resulting in a distribution with a mean of 3.2 $\pm$ 0.4 tracks and a standard deviation of 1.3 tracks. This is consistent with an automated track reconstruction, which produces a mean of 2.8 $\pm$ 0.4 tracks and a standard deviation of 1.2 tracks. Good agreement is found between data and Monte Carlo simulations for both methods. Additionally, we report the shower multiplicity and particle identification of outgoing tracks, both of which align closely with theoretical predictions. These findings will contribute to modeling of intranuclear annihilation interactions on argon, including scenarios such as neutron-antineutron oscillations.

hep-ex↗

Measurements of Pion and Muon Nuclear Capture at Rest on Argon in the LArIAT Experiment

We report the measurement of the final-state products of negative pion and muon nuclear capture at rest on argon by the LArIAT experiment at the Fermilab Test Beam Facility. We measure a population of isolated MeV-scale energy depositions, or blips, in 296 LArIAT events containing tracks from stopping low-momentum pions and muons. The average numbers of visible blips are measured to be 0.74 $\pm$ 0.19 and 1.86 $\pm$ 0.17 near muon and pion track endpoints, respectively. The 3.6$σ$ statistically significant difference in blip content between muons and pions provides the first demonstration of a new method of pion-muon discrimination in neutrino liquid argon time projection chamber experiments. LArIAT Monte Carlo simulations predict substantially higher average blip counts for negative muon (1.22 $\pm$ 0.08) and pion (2.34 $\pm$ 0.09) nuclear captures. We attribute this difference to Geant4's inaccurate simulation of the nuclear capture process.

hep-ex↗

Measurement of the ($π^-$, Ar) total hadronic cross section at the LArIAT experiment

We present the first measurement of the negative pion total hadronic cross section on argon, which we performed at the Liquid Argon In A Testbeam (LArIAT) experiment. All hadronic reaction channels, as well as hadronic elastic interactions with scattering angle greater than 5~degrees are included. The pions have a kinetic energies in the range 100-700~MeV and are produced by a beam of charged particles impinging on a solid target at the Fermilab Test Beam Facility. LArIAT employs a 0.24~ton active mass Liquid Argon Time Projection Chamber (LArTPC) to measure the pion hadronic interactions. For this measurement, LArIAT has developed the ``thin slice method", a new technique to measure cross sections with LArTPCs. While generally higher than the prediction, our measurement of the ($π^-$,Ar) total hadronic cross section is in agreement with the prediction of the Geant4 model when considering a model uncertainty of $\sim$5.1\%.

hep-ex↗

The Liquid Argon In A Testbeam (LArIAT) Experiment

The LArIAT liquid argon time projection chamber, placed in a tertiary beam of charged particles at the Fermilab Test Beam Facility, has collected large samples of pions, muons, electrons, protons, and kaons in the momentum range 300-1400 MeV/c. This paper describes the main aspects of the detector and beamline, and also reports on calibrations performed for the detector and beamline components.

physics.ins-det↗

Calorimetry for low-energy electrons using charge and light in liquid argon

Precise calorimetric reconstruction of 5-50 MeV electrons in liquid argon time projection chambers (LArTPCs) will enable the study of astrophysical neutrinos in DUNE and could enhance the physics reach of oscillation analyses. Liquid argon scintillation light has the potential to improve energy reconstruction for low-energy electrons over charge-based measurements alone. Here we demonstrate light-augmented calorimetry for low-energy electrons in a single-phase LArTPC using a sample of Michel electrons from decays of stopping cosmic muons in the LArIAT experiment at Fermilab. Michel electron energy spectra are reconstructed using both a traditional charge-based approach as well as a more holistic approach that incorporates both charge and light. A maximum-likelihood fitter, using LArIAT's well-tuned simulation, is developed for combining these quantities to achieve optimal energy resolution. A sample of isolated electrons is simulated to better determine the energy resolution expected for astrophysical electron-neutrino charged-current interaction final states. In LArIAT, which has very low wire noise and an average light yield of 18 pe/MeV, an energy resolution of $σ/E \simeq 9.3\%/\sqrt{E} \oplus 1.3\%$ is achieved. Samples are then generated with varying wire noise levels and light yields to gauge the impact of light-augmented calorimetry in larger LArTPCs. At a charge-readout signal-to-noise of S/N $\simeq$ 30, for example, the energy resolution for electrons below 40 MeV is improved by $\approx$ 10%, $\approx$ 20%, and $\approx$ 40% over charge-only calorimetry for average light yields of 10 pe/MeV, 20 pe/MeV, and 100 pe/MeV, respectively.

physics.ins-det↗

Testing of High Voltage Surge Protection Devices for Use in Liquid Argon TPC Detectors

In this paper we demonstrate the capability of high voltage varistors and gas discharge tube arrestors for use as surge protection devices in liquid argon time projection chamber detectors. The insulating and clamping behavior of each type of device is characterized in air (room temperature), and liquid argon (90~K), and their robustness under high voltage and high energy surges in cryogenic conditions is verified. The protection of vulnerable components in liquid argon during a 150 kV high voltage discharge is also demonstrated. Each device is tested for argon contamination and light emission effects, and both are constrained to levels where no significant impact upon liquid argon time projection chamber functionality is expected. Both devices investigated are shown to be suitable for HV surge protection applications in cryogenic detectors.

physics.ins-det↗