SearcharxivSearch

arXiv subjects

J. Mattingly

Publications and source records attributed to J. Mattingly.

11 recordsLinked to original sources

Measurement of coherent elastic neutrino nucleus scattering on germanium by COHERENT

The COHERENT collaboration reports the most precise measurement of the coherent elastic neutrino-nucleus scattering cross section to date. This measurement was performed with COHERENT's germanium detector array, Ge-Mini, at the Spallation Neutron Source at Oak Ridge National Laboratory. A cumulative exposure of $4.68\times10^{22}$ protons on target yielded a total number of observed counts of $124^{+14}_{-12}$ and a flux-averaged cross section of $1.00 \pm 0.10 \mathrm{(statistical)} \pm 0.10 \mathrm{(systematic)}$ relative to the standard-model expectation of $5.9\times10^{-39} \mathrm{cm}^2$. The well-understood energy and timing distributions of the neutrino source allow for independent measurements of muon- and electron-neutrino scattering rates. This information is used to improve constraints on non-standard neutrino interactions mediated by heavy particles.

hep-ex

The COHERENT Experiment: 2026 Update

The COHERENT experiment measures neutrino-induced recoils from coherent elastic neutrino-nucleus scattering (CEvNS) with multiple nuclear targets at the Spallation Neutron Source (SNS) at the Oak Ridge National Laboratory (ORNL), USA. Several successful CEvNS measurements have been achieved in recent years with tens-of-kg detector masses, with a CsI scintillating crystal, a liquid argon single-phase detector, and high-purity germanium spectrometers. For the next phase, COHERENT aims at high-statistics detection of CEvNS events for precision tests of the standard model of particle physics, and to probe new physics beyond-the-standard model. Percent-level precision can be achieved by lowering thresholds, reducing backgrounds, and by scaling up the detector masses. It goes hand in hand with benchmarking the neutrino flux from the SNS. Further detectors will measure CEvNS in additional nuclei, including lighter target nuclei such as sodium and neon, to continue to test the expected neutron-number-squared dependence of the cross section. COHERENT can furthermore study charged-current and neutral-current inelastic neutrino-nucleus cross sections on various nuclei at neutrino energies below $\sim$50 MeV. Many of these cross sections have never been measured before, but are critical input for the interpretation of core-collapse supernova detection in large-scale neutrino experiments such as DUNE, Super-K, Hyper-K, and HALO.

hep-ex

Evidence of Coherent Elastic Neutrino-Nucleus Scattering with COHERENT's Germanium Array

We report the first detection of coherent elastic neutrino-nucleus scattering (CEvNS) on natural germanium, measured at the Spallation Neutron Source at Oak Ridge National Laboratory. The Ge-Mini detector of the COHERENT collaboration employs large-mass, low-noise, high-purity germanium spectrometers, enabling excellent energy resolution, and an analysis threshold of 1.5 keV electron-equivalent ionization energy. We observe a on-beam excess of 20.6 +7.1 -6.3 counts with a total exposure of 10.22 GWhkg and we reject the no-CEvNS hypothesis with 3.9 sigma significance. The result agrees with the predicted standard model of particle physics signal rate within 2 sigma.

hep-ex

Accessing new physics with an undoped, cryogenic CsI CEvNS detector for COHERENT at the SNS

We consider the potential for a 10-kg undoped cryogenic CsI detector operating at the Spallation Neutron Source to measure coherent elastic neutrino-nucleus scattering and its sensitivity to discover new physics beyond the standard model. Through a combination of increased event rate, lower threshold, and good timing resolution, such a detector would significantly improve on past measurements. We considered tests of several beyond-the-standard-model scenarios such as neutrino non-standard interactions and accelerator-produced dark matter. This detector's performance was also studied for relevant questions in nuclear physics and neutrino astronomy, namely the weak charge distribution of CsI nuclei and detection of neutrinos from a core-collapse supernova.

hep-ex

Measurement of the Electron-Neutrino Charged-Current Cross Sections on ${}^{127}$I with the COHERENT NaI$\nu$E detector

Using an 185-kg NaI[Tl] array, COHERENT has measured the inclusive electron-neutrino charged-current cross section on ${}^{127}$I with pion decay-at-rest neutrinos produced by the Spallation Neutron Source at Oak Ridge National Laboratory. Iodine is one the heaviest targets for which low-energy ($\leq$ 50 MeV) inelastic neutrino-nucleus processes have been measured, and this is the first measurement of its inclusive cross section. After a five-year detector exposure, COHERENT reports a flux-averaged cross section for electron neutrinos of $9.2^{+2.1}_{-1.8} \times 10^{-40}$ cm$^2$. This corresponds to a value that is $\sim$41% lower than predicted using the MARLEY event generator with a measured Gamow-Teller strength distribution. In addition, the observed visible spectrum from charged-current scattering on $^{127}$I has been measured between 10 and 55 MeV, and the exclusive zero-neutron and one-or-more-neutron emission cross sections are measured to be $5.2^{+3.4}_{-3.1} \times 10^{-40}$ and $2.2^{+3.5}_{-2.2} \times 10^{-40}$ cm$^2$, respectively.

nucl-ex

Measurement of ${}^{nat}$Pb($\nu_e$,X$n$) production with a stopped-pion neutrino source

Using neutrinos produced at the Spallation Neutron Source (SNS) at Oak Ridge National Laboratory (ORNL), the COHERENT collaboration has studied the Pb($\nu_e$,X$n$) process with a lead neutrino-induced-neutron (NIN) detector. Data from this detector are fit jointly with previously collected COHERENT data on this process. A combined analysis of the two datasets yields a cross section that is $0.29^{+0.17}_{-0.16}$ times that predicted by the MARLEY event generator using experimentally-measured Gamow-Teller strength distributions, consistent with no NIN events at 1.8$\sigma$. This is the first inelastic neutrino-nucleus process COHERENT has studied, among several planned exploiting the high flux of low-energy neutrinos produced at the SNS.

hep-ex

A COHERENT constraint on leptophobic dark matter using CsI data

We use data from the COHERENT CsI[Na] scintillation detector to constrain sub-GeV leptophobic dark matter models. This detector was built to observe low-energy nuclear recoils from coherent elastic neutrino-nucleus scattering. These capabilities enable searches for dark matter particles produced at the Spallation Neutron Source mediated by a vector portal particle with masses between 2 and 400 MeV/c$^2$. No evidence for dark matter is observed and a limit on the mediator coupling to quarks is placed. This constraint improves upon previous results by two orders of magnitude. This newly explored parameter space probes the region where the dark matter relic abundance is explained by leptophobic dark matter when the mediator mass is roughly twice the dark matter mass. COHERENT sets the best constraint on leptophobic dark matter at these masses.

hep-ex

The COHERENT Experimental Program

The COHERENT experiment located in Neutrino Alley at the Spallation Neutron Source (SNS), Oak Ridge National Laboratory (ORNL), has made the world's first two measurements of coherent elastic neutrino-nucleus scattering (CEvNS), on CsI and argon, using neutrinos produced at the SNS. The COHERENT collaboration continues to pursue CEvNS measurements on various targets as well as additional studies of inelastic neutrino-nucleus interactions, searches for accelerator-produced dark matter (DM) and physics beyond the Standard Model, using the uniquely high-quality and high-intensity neutrino source available at the SNS. This white paper describes primarily COHERENT's ongoing and near-future program at the SNS First Target Station (FTS). Opportunities enabled by the SNS Second Target Station (STS) for the study of neutrino physics and development of novel detector technologies are elaborated in a separate white paper.

hep-ex

Recovery of coincident frequency domain multiplexed detector pulses using sequential deconvolution

Multiplexing of radiation detector signals into a single channel significantly reduces the need for a large number of digitizer channels, which reduces the cost and the power consumption of a data acquisition system. We previously demonstrated frequency domain multiplexing by convolution using a prototype system that multiplexed two EJ-309 organic scintillators signals into a single channel. Each detector pulse was converted to a damped sinusoid which was then combined into a single channel. The combined signal was digitized and the original detector signal was recovered from the damped sinusoid by deconvolution. In this paper, we demonstrate the recovery of multiple detector signals that arrive during the same digitized record via a new sequential deconvolution method. When two detectors produce signals in the same digitized record and their pulses do not overlap in time, we found that the charge, arrival time, and particle type can be estimated fairly precisely for the first pulse, but the second pulse exhibits substantial degradation in the precision of the estimated charge and arrival time. When the pulses overlap in time, we demonstrate both theoretically and experimentally that the part of the first pulse that does not overlap with the second can be recovered accurately, so the arrival time and amplitude of the first pulse can be estimated fairly precisely, but not the charge or particle type. None of these quantities can be estimated precisely for the second pulse when the two pulses overlap.

eess.SP

High-precision characterization of the neutron light output of stilbene along the directions of maximum and minimum response

The scintillation light output response of stilbene crystals has been measured for protons recoiling along the \textit{a}, \textit{b}, and \textit{c'} crystalline axes with energies between 1.3 and 10 MeV using neutrons produced with the tandem Van de Graaff accelerator at Triangle Universities Nuclear Laboratory. The proton recoil energy and direction were measured using the coincident detection of neutrons between a stilbene scintillator and an array of EJ-309 liquid scintillators spanning arranged neutron recoil angles. The maximum light output was found to coincide with proton recoils along the \textit{a}-axis, in disagreement with other published measurements, which reported the \textit{b}-axis as the direction of the maximum light output. Additional measurements were conducted using two different stilbene crystals to confirm these results: a second measurement using the coincident detection of neutrons; measurements of neutron full energy deposition events along the \textit{a} and \textit{b} axes; and measurements of the count rate for $^{252}$Cf neutrons traveling along the \textit{a} and \textit{b} axes directions. All measurements found that recoils along the \textit{a}-axis produce the maximum light output.

physics.ins-det

Application of deconvolution to recover frequency-domain multiplexed detector pulses

Multiplexing of radiation detectors reduces the number of readout channels, which in turn reduces the number of digitizer input channels for data acquisition. We recently demonstrated frequency domain multiplexing (FDM) of pulse mode radiation detectors using a resonator that converts the detector signal into a damped sinusoid by convolution. The detectors were given unique "tags" by the oscillation frequency of each resonator. The charge collected and the time-of-arrival of the detector pulse were estimated from the corresponding resonator output in the frequency domain. In this paper, we demonstrate a new method to recover the detector pulse from the damped sinusoidal output by deconvolution. Deconvolution converts the frequency-encoded detector signal back to the original detector pulse. We have developed a new prototype FDM system to multiplex organic scintillators based on convolution and deconvolution. Using the new prototype, the charge collected under the anode pulse can be estimated from the recovered pulse with an uncertainty of about 4.4 keVee (keV electron equivalent). The time-of-arrival can be estimated from the recovered pulse with an uncertainty of about 102 ps. We also used a CeBr3 inorganic scintillator to measure the Cs-137 gamma spectrum using the recovered pulses and found a standard deviation of 13.8 keV at 662 keV compared to a standard deviation of 13.5 keV when the original pulses were used. Coincidence measurements with Na-22 using the deconvolved pulses resulted in a timing uncertainty of 617 ps compared to an uncertainty of 603 ps using the original pulses. Pulse shape discrimination was also performed using Cf-252 source and EJ-309 organic scintillator pulses recovered by deconvolution. A figure of merit value of 1.08 was observed when the recovered pulses were used compared to 1.2 for the original pulses.

eess.SP