SearcharxivSearch

arXiv subjects

J. Milnes

Publications and source records attributed to J. Milnes.

4 recordsLinked to original sources

Test-beam demonstration of a TORCH prototype module

The TORCH time-of-flight detector is designed to provide a 15 ps timing resolution for charged particles, resulting in $\pi$/$K$ particle identification up to 10 GeV/c momentum over a 10 m flight path. Cherenkov photons, produced in a quartz plate of 10 mm thickness, are focused onto an array of micro-channel plate photomultipliers (MCP-PMTs) which measure the photon arrival times and spatial positions. A half-scale ($660\times1250\times10$ mm$^3$) TORCH demonstrator module has been tested in an 8 GeV/c mixed proton-pion beam at CERN. Customised square MCP-PMTs of active area $53\times53$ mm$^2$ and granularity $64\times64$ pixels have been employed, which have been developed in collaboration with an industrial partner. The single-photon timing performance and photon yields have been measured as a function of beam position in the radiator, giving measurements which are consistent with expectations. The expected performance of TORCH for high luminosity running of the LHCb Upgrade II has been simulated.

physics.ins-det

Status of the TORCH Project

The TORCH time-of-flight detector will provide particle identification between 2-10 GeV/c momentum over a flight distance of 10 m, and is designed for large-area coverage, up to 30 m^2. A 15 ps time-of-flight resolution per incident particle is anticipated by measuring the arrival times from Cherenkov photons produced in a synthetic fused silica radiator plate of 10 mm thickness. Customised Micro-Channel Plate Photomultiplier Tube (MCP-PMT) photon detectors of 53 x 53 mm^2 active area with a 64 x 64 granularity have been developed with industrial partners. Test-beam studies using both a small-scale TORCH demonstrator and a half-length TORCH module are presented. The desired timing resolution of 70 ps per single photon is close to being achieved.

physics.ins-det

Test-beam studies of a small-scale TORCH time-of-flight demonstrator

TORCH is a time-of-flight detector designed to perform particle identification over the momentum range 2$-$10 GeV/c for a 10 m flight path. The detector exploits prompt Cherenkov light produced by charged particles traversing a quartz plate of 10 mm thickness. Photons are then trapped by total internal reflection and directed onto a detector plane instrumented with customised position-sensitive Micro-Channel Plate Photo-Multiplier Tube (MCP-PMT) detectors. A single-photon timing resolution of 70 ps is targeted to achieve the desired separation of pions and kaons, with an expectation of around 30 detected photons per track. Studies of the performance of a small-scale TORCH demonstrator with a radiator of dimensions 120 $\times$ 350 $\times$ 10 mm$^3$ have been performed in two test-beam campaigns during November 2017 and June 2018. Single-photon time resolutions ranging from 104.3 ps to 114.8 ps and 83.8 ps to 112.7 ps have been achieved for MCP-PMTs with granularity 4 $\times$ 64 and 8 $\times$ 64 pixels, respectively. Photon yields are measured to be within $\sim$10% and $\sim$30% of simulation, respectively. Finally, the outlook for future work with planned improvements is presented.

physics.ins-det

A position- and time-sensitive photon-counting detector with delay-line read-out

We have developed image intensifier tubes with delay-anode read-out for time- and position-sensitive photon counting. The timing precision is better than 1 ns with 1000x1000 pixels position resolution and up to one megacounts/s processing rate. Large format detectors of 40 and 75 mm active diameter with internal helical-wire delay-line anodes have been produced and specified. A different type of 40 and 25 mm tubes with semi-conducting screen for image charge read-out allow for an economic and robust tube design and for placing the read-out anodes outside the sealed housing. Two types of external delay-line anodes, i.e. pick-up electrodes for the image charge, have been tested. We present tests of the detector and anode performance. Due to the low background this technique is well suited for applications with very low light intensity and especially if a precise time tagging for each photon is required. As an example we present the application of scintillator read-out in time-of-flight (TOF) neutron radiography. Further applications so far are Fluorescence Life-time Microscopy (FLIM) and Astronomy

physics.ins-det