SearcharxivSearch

arXiv subjects

J. N. Ullom

Publications and source records attributed to J. N. Ullom.

At least 19 recordsLinked to original sources

A microwave SQUID multiplexing concept for macro-cryogenic calorimeter arrays

Massive cryogenic calorimeters read out by transition-edge sensors (TES) can reach eV-scale baseline resolution, but the single-channel dc-SQUID readout conventionally used in rare-event searches, with one amplifier chain and several wires per detector, limits practical arrays to a few tens of channels. We propose to apply microwave SQUID multiplexing ($μ$MUX), developed for fast X-ray and neutrino-mass microcalorimeters, to massive BGO (Bi$_4$Ge$_3$O$_{12}$) calorimeters operated at $\simeq 20$~mK; sapphire and TeO$_2$ absorbers are covered by the same framework. Using the established thermal and noise model for massive TES calorimeters, we derive a noise model for the multiplexed readout, including the HEMT, two-level-system and SQUID contributions, and its scaling with the multiplexing factor $N_{\rm mux}$. Since the slow thermal signals require only about a kHz of sampling per channel, the limiting requirement is not bandwidth but an input-coil sensitivity of $( 0.1$ to $1)\,μ$A$/Φ_0$, a factor of $10$ to $30$ beyond current $μ$MUX devices, matched to the detector current noise of ($9$ to $10$)~pA$/\sqrt{\rm Hz}$, which is independent of the absorber mass. With a total flux noise of $\simeq$$1.2\,μΦ_0/\sqrt{\rm Hz}$, the readout degrades the baseline resolution by less than $2\%$ up to $N_{\rm mux}=1000$, negligible compared with the TES-limited resolution. These results are implemented in a single-tower design: 52 BGO crystals of 100~g each and one HEMT amplifier. The tower is the unit of a multi-tower array of several kilograms aimed at CE$ν$NS and dark matter searches.

physics.ins-det

Demonstration of a cryogenic, switchable electron source for low-temperature detector calibration

We present the realization of a prototype of a compact, switchable electron source operating at cryogenic temperatures, demonstrated at energies ranging from 100 eV to 300 eV, and conceptually extendable to an arbitrary energy range. The electrons are produced via photoelectric emission, induced by a LED illuminating two 400~nm-thick commercial aluminum layers inside a cryostat, and are subsequently accelerated by a voltage of up to 300~V. Detection is carried out with an array of transition-edge sensor (TES) microcalorimeters designed for X-ray detectors, where we successfully observe signals consistent with electrons produced at the source at rates of $\gtrsim$1~Hz and with an efficiency of $\gtrsim 10^{-14}\ e^-/γ$. One of the potential applications of this prototype is the development of a calibration method for cryogenic detectors, based on the generation, acceleration, and multiplication of electrons, followed by their conversion into high-energy photons.

physics.ins-det

X-ray magnetic circular dichroism and resonant inelastic X-ray scattering explained: role of many-body correlation and valence fluctuations

X-ray magnetic circular dichroism (XMCD) and resonant inelastic X-ray scattering with magnetic circular dichroism (RIXS-MCD) provide unparalleled insights into the electronic and magnetic dynamics of complex materials. However, interpreting their spectra in mixed-valence systems remains challenging due to intricate many-body interactions and enhanced charge fluctuations. In this study, by utilizing the Anderson impurity model with a full consideration of charge transfer (CT), many-body core-valence exchange correlation (CVEC) effects, and Jahn-Teller (JT) distortions, we systematically investigate the XMCD and RIXS-MCD spectra for a prototypical mixed-valence ferromagnet, La$_{0.7}$Sr$_{0.3}$MnO$_3$ film. We demonstrate that simple calculation with limited CT effects fails to capture characteristic substructures observed experimentally. In contrast, an adequate treatment of CT and CVEC effects yields a more consistent description of both XMCD and RIXS-MCD spectra, providing practical guidance for the interpretation of dichroic x-ray spectroscopies in mixed-valence transition-metal oxides. Furthermore, we discuss the role of the JT effect in Mn$^{3+}$ ions in the determination of their spectra.

cond-mat.str-el

Phenomenological Modeling of the $^{163}$Ho Calorimetric Electron Capture Spectrum from the HOLMES Experiment

We present a comprehensive phenomenological analysis of the calorimetric electron capture (EC) decay spectrum of $^{163}$Ho as measured by the HOLMES experiment. Using high-statistics data, we unfold the instrumental energy resolution from the measured spectrum and model it as a sum of Breit-Wigner resonances and shake-off continua, providing a complete set of parameters for each component. Our approach enables the identification and tentative interpretation of all observed spectral features, including weak and overlapping structures, in terms of atomic de-excitation processes. We compare our phenomenological model with recent ab initio theoretical calculations, finding good agreement for both the main peaks and the spectral tails, despite the limitations of current theoretical and experimental precision. The model delivers an accurate description of the endpoint region, which is crucial for neutrino mass determination, and allows for a realistic treatment of backgrounds such as pile-up and tails of low-energy components. Furthermore, our decomposition facilitates the generation of Monte Carlo toy spectra for sensitivity studies and provides a framework for investigating systematic uncertainties related to solid-state and detector effects. This work establishes a robust foundation for future calorimetric neutrino mass experiments employing $^{163}$Ho, supporting both data analysis and experimental design.

nucl-ex

Most stringent bound on electron neutrino mass obtained with a scalable low temperature microcalorimeter array

The determination of the absolute neutrino mass scale remains a fundamental open question in particle physics, with profound implications for both the Standard Model and cosmology. Direct kinematic measurements, independent of model-dependent assumptions, provide the most robust approach to address this challenge. In this Letter, we present the most stringent upper bound on the effective electron neutrino mass ever obtained with a calorimetric measurement of the electron capture decay of $^{163}$Ho. The HOLMES experiment employs an array of ion-implanted transition-edge sensor (TES) microcalorimeters, achieving an average energy resolution of 6 eV FWHM with a scalable, multiplexed readout technique. With a total of $7\times10^7$ decay events recorded over two months and a Bayesian statistical analysis, we derive an upper limit of $m_β<27$ eV/c$^2$ at 90% credibility. These results validate the feasibility of $^{163}$Ho calorimetry for next-generation neutrino mass experiments and demonstrate the potential of a scalable TES-based microcalorimetric technique to push the sensitivity of direct neutrino mass measurements beyond the current state of the art.

hep-ex

Measurable Improvement in Multi-Qubit Readout Using a Kinetic Inductance Traveling Wave Parametric Amplifier

Increasing the size and complexity of quantum information systems requires highly-multiplexed readout architectures, as well as amplifier chains operating near the quantum limit (QL) of added noise. While documented prior efforts in KITWPA integration in quantum systems are scarce, in this work we demonstrate integration of a KI-TWPA with a multiplexed-qubit device. To quantify the system noise improvement we perform an ac Stark shift calibration to precisely determine noise power levels on-chip (at each cavity's reference plane) and the total system gain. We then characterize the qubit state measurement fidelity and the corresponding signal-to-noise ratio (SNR). To conduct the most faithful measurement of the benefits offered by the KI-TWPA we perform these measurements for readout chains where the high electron mobility transistor (HEMT) amplifier is the first-stage amplifier (FSA) - with none of the external hardware required to operate the KI-TWPA - and with the KI-TWPA as the FSA. While some readout cavities fall outside the KI-TWPA bandwidth, for those inside the bandwidth we demonstrate a maximum improvement in the state measurement SNR by a factor of 1.45, and increase the fidelity from 96.2% to 97.8%. These measurements demonstrate a system noise below 5 quanta referenced on-chip and we bound the KI-TWPA excess noise to be below 4 quanta for the six cavities inside its bandwidth. These results show a promising path forward for realizing quantum-limited readout chains in large qubit systems using a single parametric amplifier.

quant-ph

Few-electron highly charged muonic Ar atoms verified by electronic $K$ x rays

Electronic $K$ x rays emitted by muonic Ar atoms in the gas phase were observed using a superconducting transition-edge-sensor microcalorimeter. The high-precision energy spectra provided a clear signature of the presence of muonic atoms accompanied by a few electrons, which have never been observed before. One-, two-, and three-electron bound, i.e., H-like, He-like, and Li-like, muonic Ar atoms were identified from electronic $K$ x rays and hyper-satellite $K$ x rays. These $K$ x rays are emitted after the charge transfer process by the collisions with surrounding Ar atoms. With the aid of theoretical calculations, we confirmed that the peak positions are consistent with the x-ray energies from highly charged Cl ions, and the intensities reflecting deexcitation dynamics were successfully understood by taking into account the interaction between the muon and bound electrons.

physics.atom-ph

Characterization of NbTiN films with thicknesses below 20 nm for low power kinetic inductance amplifiers

A quantum-limited amplification chain is a fundamental advantage for any application that may benefit from the detection of very faint signals. Reading out arrays of superconducting detectors (TESs or MKIDs), resonant cavities, or qubits, calls for large bandwidth amplifiers in addition to having the lowest possible noise. At millikelvin temperatures, Kinetic Inductance Traveling-Wave Parametric Amplifiers (KI-TWPAs) working in 3-wave-mixing (3WM) and fabricated from a 20 nm thick NbTiN film have shown promising noise performances, as they can operate close to the quantum limit. However, they still require fairly high pump power. Devices that would require lower pump power would be easier to implement in readout chains, could reach the quantum limit and they would be compatible with qubit readout. A possible solution for obtaining this optimal configuration is to use a thinner superconducting film. In this work we explore the properties of NbTiN films with a thickness less than 20 nm and we report the obtained experimental characterizations in terms of critical temperature, normal resistivity, and kinetic inductance. A new design for a 3WM KI-TWPA amplifier, based on these developed superconducting films, is introduced and discussed.

cond-mat.supr-con

Improved microwave SQUID multiplexer readout using a kinetic-inductance traveling-wave parametric amplifier

We report on the use of a kinetic-inductance traveling-wave parametric amplifier (KITWPA) as the first amplifier in the readout chain of a microwave superconducting quantum interference device (SQUID) multiplexer (umux). This umux is designed to multiplex signals from arrays of low temperature detectors such as superconducting transition-edge sensor microcalorimeters. When modulated with a periodic flux-ramp to linearize the SQUID response, the flux noise improves, on average, from $1.6$ $μΦ_0/\sqrt{\mathrm{Hz}}$ with the KITWPA off, to $0.77$ $μΦ_0/\sqrt{\mathrm{Hz}}$ with the KITWPA on. When statically biasing the umux to the maximally flux-sensitive point, the flux noise drops from $0.45$ $μΦ_0/\sqrt{\mathrm{Hz}}$ to $0.2$ $μΦ_0/\sqrt{\mathrm{Hz}}$. We validate this new readout scheme by coupling a transition-edge sensor microcalorimeter to the umux and detecting background radiation. The combination of umux and KITWPA provides a variety of new capabilities including improved detector sensitivity and more efficient bandwidth utilization.

astro-ph.IM

G4CMP: Condensed Matter Physics Simulation Using the Geant4 Toolkit

G4CMP simulates phonon and charge transport in cryogenic semiconductor crystals using the Geant4 toolkit. The transport code is capable of simulating the propagation of acoustic phonons as well as electron and hole charge carriers. Processes for anisotropic phonon propagation, oblique charge-carrier propagation, and phonon emission by accelerated charge carriers are included. The simulation reproduces theoretical predictions and experimental observations such as phonon caustics, heat-pulse propagation times, and mean charge-carrier drift velocities. In addition to presenting the physics and features supported by G4CMP, this report outlines example applications from the dark matter and quantum information science communities. These communities are applying G4CMP to model and design devices for which the energy transported by phonons and charge carriers is germane to the performance of superconducting instruments and circuits placed on silicon and germanium substrates. The G4CMP package is available to download from GitHub: github.com/kelseymh/G4CMP.

hep-ex

The potential of microcalorimeter x-ray spectrometers for measurement of relative fluorescence-line intensities

We have previously used an array of cryogenic microcalorimeters with 4 eV energy resolution to measure emission-line profiles and energies of the characteristic L-shell x rays of four elements of the lanthanide series: praseodymium, neodymium, terbium, and holmium. We consider the power of the same data set for the estimation of the lines' relative intensities. Intensities must be corrected for detector efficiency and self-absorption, and we estimate uncertainties on the corrections. These data represent one of the first uses of cryogenic energy-dispersive sensors to estimate the relative intensities of x-ray fluorescence lines. They show that a future measurement of thin-film samples with microcalorimeter detectors could achieve systematic uncertainties below 1% on relative line intensities over a broad energy range.

physics.ins-det

CCAT-prime Collaboration: Science Goals and Forecasts with Prime-Cam on the Fred Young Submillimeter Telescope

We present a detailed overview of the science goals and predictions for the Prime-Cam direct detection camera/spectrometer being constructed by the CCAT-prime collaboration for dedicated use on the Fred Young Submillimeter Telescope (FYST). The FYST is a wide-field, 6-m aperture submillimeter telescope being built (first light in mid-2024) by an international consortium of institutions led by Cornell University and sited at more than 5600 meters on Cerro Chajnantor in northern Chile. Prime-Cam is one of two instruments planned for FYST and will provide unprecedented spectroscopic and broadband measurement capabilities to address important astrophysical questions ranging from Big Bang cosmology through reionization and the formation of the first galaxies to star formation within our own Milky Way galaxy. Prime-Cam on the FYST will have a mapping speed that is over ten times greater than existing and near-term facilities for high-redshift science and broadband polarimetric imaging at frequencies above 300 GHz. We describe details of the science program enabled by this system and our preliminary survey strategies.

astro-ph.CO

Energy calibration of nonlinear microcalorimeters with uncertainty estimates from Gaussian process regression

The nonlinear energy response of cryogenic microcalorimeters is usually corrected through an empirical calibration. X-ray or gamma-ray emission lines of known shape and energy anchor a smooth function that generalizes the calibration data and converts detector measurements to energies. We argue that this function should be an approximating spline. The theory of Gaussian process regression makes a case for this functional form. It also provides an important benefit previously absent from our calibration method: a quantitative uncertainty estimate for the calibrated energies, with lower uncertainty near the best-constrained calibration points.

physics.ins-det

Performance of a Kinetic-Inductance Traveling-Wave Parametric Amplifier at 4 Kelvin: Toward an Alternative to Semiconductor Amplifiers

Most microwave readout architectures in quantum computing or sensing rely on a semiconductor amplifier at 4 K, typically a high-electron mobility transistor (HEMT). Despite its remarkable noise performance, a conventional HEMT dissipates several milliwatts of power, posing a practical challenge to scale up the number of qubits or sensors addressed in these architectures. As an alternative, we present an amplification chain consisting of a kinetic-inductance traveling-wave parametric amplifier (KI-TWPA) placed at 4 K, followed by a HEMT placed at 70 K, and demonstrate a chain-added noise $T_Σ= 6.3\pm0.5$ K between 3.5 and 5.5 GHz. While, in principle, any parametric amplifier can be quantum limited even at 4 K, in practice we find the KI-TWPA's performance limited by the temperature of its inputs, and by an excess of noise $T_\mathrm{ex} = 1.9$ K. The dissipation of the KI-TWPA's rf pump constitutes the main power load at 4 K and is about one percent that of a HEMT. These combined noise and power dissipation values pave the way for the KI-TWPA's use as a replacement for semiconductor amplifiers.

quant-ph

A Microwave SQUID Multiplexer Optimized for Bolometric Applications

A microwave SQUID multiplexer ($μ$MUX) has been optimized for coupling to large arrays of superconducting transition-edge sensor (TES) bolometers. We present the scalable cryogenic multiplexer chip design in a 1820-channel multiplexer configuration for the 4-8 GHz rf band. The key metrics of yield, sensitivity, and crosstalk are determined through measurements of 455 readout channels, which span 4-5 GHz. The median white-noise level is 45 pA/$\sqrt{\textrm{Hz}}$, evaluated at 2 Hz, with a 1/f knee $\leq$ 20 mHz after common-mode subtraction. The white-noise level decreases the sensitivity of a TES bolometer optimized for detection of the cosmic microwave background at 150 GHz by only 3%. The measured crosstalk between any channel pair is $\leq$ 0.3%.

astro-ph.IM

Progress in the development of TES microcalorimeter detectors suitable for neutrino mass measurement

The HOLMES experiment will perform a precise calorimetric measurement of the end point of the Electron Capture (EC) decay spectrum of 163Ho in order to extract information on neutrino mass with a sensitivity below 2 eV. In its final configuration, HOLMES will deploy 1000 detectors of low-temperature microcalorimeters with implanted 163Ho nuclei. The baseline sensors for HOLMES are Mo/Cu TESs (Transition Edge Sensors) on SiNx membrane with gold absorbers. Considering the large number of pixels and an event rate of about 300 Hz/pixel, a large multiplexing factor and a large bandwidth are needed. To fulfill this requirement, HOLMES will exploit recent advances in microwave multiplexing. In this contribution, we present the status of the activities in development, the performances of the developed microwave-multiplexed readout system, and the results obtained with the detectors specifically designed for HOLMES in terms of noise, time, and energy resolutions

physics.ins-det

Sub-Kelvin Thermometer for On-Chip Measurements of Microwave Devices Utilizing Two-Level Systems in Superconducting Microresonators

We present a superconducting microresonator thermometer based on two-level systems (TLS) that is drop-in compatible with cryogenic microwave systems. The operational temperature range is 50-1000~mK (which may be extended to 5~mK), and the sensitivity (50-75~$μ$K/$\sqrt{\mathrm{Hz}}$) is relatively uniform across this range. The miniature footprint that conveniently attaches to the feedline of a cryogenic microwave device facilitates the measurement of on-chip device temperature and requires no additional thermometry wiring or readout electronics. We demonstrate the practical use of these TLS thermometers to investigate static and transient chip heating in a kinetic inductance traveling-wave parametric amplifier operated with a strong pump tone. TLS thermometry may find broad application in cryogenic microwave devices such as superconducting qubits and detectors.

physics.ins-det

A three-wave mixing kinetic inductance traveling-wave amplifier with near-quantum-limited noise performance

We present a theoretical model and experimental characterization of a microwave kinetic inductance traveling-wave amplifier (KIT), whose noise performance, measured by a shot-noise tunnel junction (SNTJ), approaches the quantum limit. Biased with a dc current, the KIT operates in a three-wave mixing fashion, thereby reducing by several orders of magnitude the power of the microwave pump tone and associated parasitic heating compared to conventional four-wave mixing KIT devices. It consists of a 50 Ohms artificial transmission line whose dispersion allows for a controlled amplification bandwidth. We measure $16.5^{+1}_{-1.3}$ dB of gain across a 2 GHz bandwidth with an input 1 dB compression power of -63 dBm, in qualitative agreement with theory. Using a theoretical framework that accounts for the SNTJ-generated noise entering both the signal and idler ports of the KIT, we measure the system-added noise of an amplification chain that integrates the KIT as the first amplifier. This system-added noise, $3.1\pm0.6$ quanta (equivalent to $0.66\pm0.15$ K) between 3.5 and 5.5 GHz, is the one that a device replacing the SNTJ in that chain would see. This KIT is therefore suitable to read large arrays of microwave kinetic inductance detectors and promising for multiplexed superconducting qubit readout.

quant-ph