Searcharxiv⌕ Search

arXiv subjects

J. Osterhoff

Publications and source records attributed to J. Osterhoff.

At least 37 records · Page 2Linked to original sources

Longitudinally resolved measurement of energy-transfer efficiency in a plasma-wakefield accelerator

Energy-transfer efficiency is an important quantity in plasma-wakefield acceleration, especially for applications that demand high average power. Conventionally, the efficiency is measured using an electron spectrometer; an invasive method that provides an energy-transfer efficiency averaged over the full length of the plasma accelerator. Here, we experimentally demonstrate a novel diagnostic utilizing the excess light emitted by the plasma after a beam-plasma interaction, which yields noninvasive, longitudinally resolved measurements of the local energy-transfer efficiency from the wake to the accelerated bunch; here, as high as (58 $\pm$ 3)%. This method is suitable for online optimization of individual stages in a future multistage plasma accelerator, and enables experimental studies of the relation between efficiency and transverse instability in the acceleration process.

physics.acc-ph↗

Energy Compression and Stabilization of Laser-Plasma Accelerators

Laser-plasma accelerators outperform current radiofrequency technology in acceleration strength by orders of magnitude. Yet, enabling them to deliver competitive beam quality for demanding applications, particularly in terms of energy spread and stability, remains a major challenge. In this Letter, we propose to combine bunch decompression and active plasma dechirping for drastically improving the energy profile and stability of beams from laser-plasma accelerators. Realistic start-to-end simulations demonstrate the potential of these post-acceleration phase-space manipulations for simultaneously reducing an initial energy spread and energy jitter of $\sim1$-$2\%$ to ${\lesssim} 0.1 \%$, closing the beam-quality gap to conventional acceleration schemes.

physics.acc-ph↗

Self-stabilizing positron acceleration in a plasma column

Plasma accelerators sustain extreme field gradients, and potentially enable future compact linear colliders. Although tremendous progress has been achieved in accelerating electron beams in a plasma accelerator, positron acceleration with collider-relevant parameters is challenging. A recently proposed positron acceleration scheme relying on the wake generated by an electron drive beam in a plasma column has been shown to be able to accelerate positron witness beams with low emittance and low energy spread. However, since this scheme relies on cylindrical symmetry, it is possibly prone to transverse instabilities that could lead, ultimately, to beam break-up. In this article, we show that the witness beam itself is subject to various damping mechanisms and, therefore, this positron acceleration scheme is inherently stable towards misalignment of the drive and witness beams. This enables stable, high-quality plasma-based positron acceleration.

physics.acc-ph↗

European Strategy for Particle Physics -- Accelerator R&D Roadmap

The 2020 update of the European Strategy for Particle Physics emphasised the importance of an intensified and well-coordinated programme of accelerator R&D, supporting the design and delivery of future particle accelerators in a timely, affordable and sustainable way. This report sets out a roadmap for European accelerator R&D for the next five to ten years, covering five topical areas identified in the Strategy update. The R&D objectives include: improvement of the performance and cost-performance of magnet and radio-frequency acceleration systems; investigations of the potential of laser / plasma acceleration and energy-recovery linac techniques; and development of new concepts for muon beams and muon colliders. The goal of the roadmap is to document the collective view of the field on the next steps for the R&D programme, and to provide the evidence base to support subsequent decisions on prioritisation, resourcing and implementation.

physics.acc-ph↗

Recovery time of a plasma-wakefield accelerator

The interaction of intense particle bunches with plasma can give rise to plasma wakes capable of sustaining gigavolt-per-metre electric fields, which are orders of magnitude higher than provided by state-of-the-art radio-frequency technology. Plasma wakefields can, therefore, strongly accelerate charged particles and offer the opportunity to reach higher particle energies with smaller and hence more widely available accelerator facilities. However, the luminosity and brilliance demands of high-energy physics and photon science require particle bunches to be accelerated at repetition rates of thousands or even millions per second, which are orders of magnitude higher than demonstrated with plasma-wakefield technology. Here we investigate the upper limit on repetition rates of beam-driven plasma accelerators by measuring the time it takes for the plasma to recover to its initial state after perturbation by a wakefield. The many-nanosecond-level recovery time measured establishes the in-principle attainability of megahertz rates of acceleration in plasmas. The experimental signatures of the perturbation are well described by simulations of a temporally evolving parabolic ion channel, transferring energy from the collapsing wake to the surrounding media. This result establishes that plasma-wakefield modules could be developed as feasible high-repetition-rate energy boosters at current and future particle-physics and photon-science facilities.

physics.acc-ph↗

Progress of the FLASHForward X-2 high-beam-quality, high-efficiency plasma-accelerator experiment

FLASHForward is an experimental facility at DESY dedicated to beam-driven plasma-accelerator research. The X-2 experiment aims to demonstrate acceleration with simultaneous beam-quality preservation and high energy efficiency in a compact plasma stage. We report on the completed commissioning, first experimental results, ongoing research topics, as well as plans for future upgrades.

physics.acc-ph↗

Design of a prototype laser-plasma injector for the DESY-II synchrotron

The present state of progress in laser wakefield acceleration encourages considering it as a practical alternative to conventional particle accelerators. A promising application would be to use a laser-plasma accelerator as an injector for a synchrotron light source. Yet, the energy spread and jitter of the laser-plasma beam pose a significant difficulty for an efficient injection. In this paper we propose a design of a prototype injector to deliver 500 MeV low-intensity electron bunches to the DESY-II electron synchrotron. The design utilizes presently available conventional accelerator technology, such as a chicane and an X-band radio frequency cavity, to reduce the energy spread and jitter of the electron beam down to a sub-per-mille level.

physics.acc-ph↗

A laser-plasma platform for photon-photon physics

We describe a laser-plasma platform for photon-photon collision experiments to measure fundamental quantum electrodynamic processes such as the linear Breit-Wheeler process with real photons. The platform has been developed using the Gemini laser facility at the Rutherford Appleton Laboratory. A laser wakefield accelerator and a bremsstrahlung convertor are used to generate a collimated beam of photons with energies of hundreds of MeV, that collide with keV x-ray photons generated by a laser heated plasma target. To detect the pairs generated by the photon-photon collisions, a magnetic transport system has been developed which directs the pairs onto scintillation-based and hybrid silicon pixel single particle detectors. We present commissioning results from an experimental campaign using this laser-plasma platform for photon-photon physics, demonstrating successful generation of both photon sources, characterisation of the magnetic transport system and calibration of the single particle detectors, and discuss the feasibility of this platform for the observation of the Breit-Wheeler process. The design of the platform will also serve as the basis for the investigation of strong-field quantum electrodynamic processes such as the nonlinear Breit-Wheeler and the Trident process, or eventually, photon-photon scattering.

physics.plasm-ph↗

Developing a 50 MeV LPA-based Injector at ATHENA for a Compact Storage Ring

The laser-driven generation of relativistic electron beams in plasma and their acceleration to high energies with GV/m-gradients has been successfully demonstrated. Now, it is time to focus on the application of laser-plasma accelerated (LPA) beams. The "Accelerator Technology HElmholtz iNfrAstructure" (ATHENA) of the Helmholtz Association fosters innovative particle accelerators and high-power laser technology. As part of the ATHENAe pillar several different applications driven by LPAs are to be developed, such as a compact FEL, medical imaging and the first realization of LPA-beam injection into a storage ring. The latter endeavour is conducted in close collaboration between Deutsches Elektronen-Synchrotron (DESY), Karlsruhe Institute of Technology (KIT) and Helmholtz Institute Jena (HIJ). In the cSTART project at KIT, a compact storage ring optimized for short bunches and suitable to accept LPA-based electron bunches is in preparation. In this conference contribution we will introduce the 50 MeV LPA-based injector and give an overview about the project goals. The key parameters of the plasma injector will be presented. Finally, the current status of the project will be summarized.

physics.acc-ph↗

Multi-kT/m Focusing Gradient in a Linear Active Plasma Lens

Active plasma lenses are compact devices developed as a promising beam-focusing alternative for charged particle beams, capable of short focal lengths for high-energy beams. We have previously shown that linear magnetic fields with gradients of around 0.3 kT/m can be achieved in argon-filled plasma lenses that preserve beam emittance [C.A. Lindstrøm et al., Phys. Rev. Lett. 121, 194801 (2018)]. Here we show that with argon in a 500 μm diameter capillary, the fields are still linear with a focusing gradient of 3.6 kT/m, which is an order of magnitude higher than the gradients of quadrupole magnets. The current pulses that generate the magnetic field are provided by compact Marx banks, and are highly repeatable. These results establish active plasma lenses as an ideal device for pulsed particle beam applications requiring very high focusing gradients that are uniform throughout the lens aperture.

physics.acc-ph↗

Automation and control of laser wakefield accelerators using Bayesian optimisation

Laser wakefield accelerators promise to revolutionise many areas of accelerator science. However, one of the greatest challenges to their widespread adoption is the difficulty in control and optimisation of the accelerator outputs due to coupling between input parameters and the dynamic evolution of the accelerating structure. Here, we use machine learning techniques to automate a 100 MeV-scale accelerator, which optimised its outputs by simultaneously varying up to 6 parameters including the spectral and spatial phase of the laser and the plasma density and length. Most notably, the model built by the algorithm enabled optimisation of the laser evolution that might otherwise have been missed in single-variable scans. Subtle tuning of the laser pulse shape caused an 80% increase in electron beam charge, despite the pulse length changing by just 1%.

physics.acc-ph↗

Evolution of longitudinal plasma-density profiles in discharge capillaries for plasma wakefield accelerators

Precise characterization and tailoring of the spatial and temporal evolution of plasma density within plasma sources is critical for realizing high-quality accelerated beams in plasma wakefield accelerators. The simultaneous use of two independent diagnostic techniques allowed the temporally and spatially resolved detection of plasma density with unprecedented sensitivity and enabled the characterization of the plasma temperature at local thermodynamic equilibrium in discharge capillaries. A common-path two-color laser interferometer for obtaining the average plasma density with a sensitivity of $2\times 10^{15}$ cm$^{-2}$ was developed together with a plasma emission spectrometer for analyzing spectral line broadening profiles with a resolution of $5\times 10^{15}$ cm$^{-3}$. Both diagnostics show good agreement when applying the spectral line broadening analysis methodology of Gigosos and Carde{ñ}oso. Measured longitudinally resolved plasma density profiles exhibit a clear temporal evolution from an initial flat-top to a Gaussian-like shape in the first microseconds as material is ejected out from the capillary, deviating from the often-desired flat-top profile. For plasma with densities of 0.5-$2.5\times 10^{17}$ cm$^{-3}$, temperatures of 1-7 eV were indirectly measured. These measurements pave the way for highly detailed parameter tuning in plasma sources for particle accelerators and beam optics.

physics.plasm-ph↗

Plasma Sources and Diagnostics

Carefully engineered, controlled, and diagnosed plasma sources are a key ingredient in mastering plasma-based particle accelerator technology. This work reviews basic physics concepts, common types of plasma sources, and available diagnostic techniques to provide a starting point for advanced research into this field.

physics.acc-ph↗

Matching small $β$ functions using centroid jitter and two beam position monitors

Matching to small beta functions is required to preserve emittance in plasma accelerators. The plasma wake provides strong focusing fields, which typically require beta functions on the mm-scale, comparable to those found in the final focusing of a linear collider. Such beams can be time consuming to experimentally produce and diagnose. We present a simple, fast, and noninvasive method to measure Twiss parameters in a linac using two beam position monitors only, relying on the similarity of the beam phase space and the jitter phase space. By benchmarking against conventional quadrupole scans, the viability of this technique was experimentally demonstrated at the FLASHForward plasma-accelerator facility.

physics.acc-ph↗

Tunable and precise two-bunch generation at FLASHForward

Beam-driven plasma-wakefield acceleration based on external injection has the potential to significantly reduce the size of future accelerators. Stability and quality of the acceleration process substantially depends on the incoming bunch parameters. Precise control of the current profile is essential for optimising energy-transfer efficiency and preserving energy spread. At the FLASHForward facility, driver--witness bunch pairs of adjustable bunch length and separation are generated by a set of collimators in a dispersive section, which enables fs-level control of the longitudinal bunch profile. The design of the collimator apparatus and its commissioning is presented.

physics.acc-ph↗

Hybrid LWFA $\vert$ PWFA Staging as a Beam Energy and Brightness Transformer : Conceptual Design and Simulations

We present a conceptual design for a hybrid laser-to-beam-driven plasma wakefield accelerator. In this setup, the output beams from a laser-driven plasma wakefield accelerator (LWFA) stage are used as input beams of a new beam-driven plasma accelerator (PWFA) stage. In the PWFA stage a new witness beam of largely increased quality can be produced and accelerated to higher energies. The feasibility and the potential of this concept is shown through exemplary particle-in-cell simulations. In addition, preliminary simulation results for a proof-of-concept experiment at HZDR (Germany) are shown.

physics.acc-ph↗

FLASHForward: Plasma-wakefield accelerator science for high-average-power applications

The FLASHForward experimental facility is a high-performance test-bed for precision plasma-wakefield research, aiming to accelerate high-quality electron beams to GeV-levels in a few centimetres of ionised gas. The plasma is created by ionising gas in a gas cell either by a high-voltage discharge or a high-intensity laser pulse. The electrons to be accelerated will either be injected internally from the plasma background or externally from the FLASH superconducting RF front end. In both cases the wakefield will be driven by electron beams provided by the FLASH gun and linac modules operating with a 10 Hz macro-pulse structure, generating 1.25 GeV, 1 nC electron bunches at up to 3 MHz micro-pulse repetition rates. At full capacity, this FLASH bunch-train structure corresponds to 30 kW of average power, orders of magnitude higher than drivers available to other state-of-the-art LWFA and PWFA experiments. This high-power functionality means FLASHForward is the only plasma-wakefield facility in the world with the immediate capability to develop, explore, and benchmark high-average-power plasma-wakefield research essential for next-generation facilities. The operational parameters and technical highlights of the experiment are discussed, as well as the scientific goals and high-average-power outlook.

physics.acc-ph↗