SearcharxivSearch

arXiv subjects

J. P. Davis

Publications and source records attributed to J. P. Davis.

At least 19 recordsLinked to original sources

Overcoming intrinsic material limitations through cavity feedback

Magnons, the quanta of spin waves, have significant potential for use in modern technologies, especially when strongly coupled to another mode for read-out and control. However, while magnons strongly interact with microwave photons via the magnetic-dipole interaction to form hybrid cavity-magnon polariton modes, the weak magnetostrictive magnon-phonon interaction, together with large polariton linewidths dominated by magnon dissipation, has so far restricted magnonic-spheres to the weak-coupling regime. The material-limited magnon dissipation rate in particular has been regarded as an unavoidable limitation in these systems. Here, we surpass this long-standing limitation by implementing an active microwave feedback loop to suppress the linewidth of cavity-magnon polaritons and strongly suppress their effective decay rate below the magnon-limited linewidth, thereby enhancing the polariton-phonon cooperativity from C=1 to C=150. As a key milestone, we achieve normal-mode splitting between a cavity-magnon polariton and a mechanical mode, providing direct evidence of three-mode hybridization among photons, magnons, and phonons. Our results establish feedback as a general route to accessing strong-coupling regimes in systems previously thought to be limited by material properties and hence open new opportunities for coherent control in hybrid quantum systems.

cond-mat.mes-hall

Coherent Perfect Absorption: Zero Reflection Without Linewidth Suppression

Motivated by recent claims, we revisit how coherent perfect absorption (CPA) influences cavity and polaritonic linewidths. Using standard input output theory and measurements on single port bare microwave cavities and cavity magnon hybrids, we find that CPA drives the on resonance reflection to zero while the spectral width remains set by the total decay rate. Apparent narrowing observed near CPA is found to be a visual artifact that does not remain upon quantitative analysis. Extending the analysis to cavity magnomechanics, we show that logarithmic plots can exhibit apparent polaromechanical normal mode splitting, whereas linear scale spectra display no true splitting. These results clarify when CPA modifies amplitudes versus spectral poles, offer practical guidance for data presentation, and indicate that CPA alone is not a route to linewidth suppression or polaromechanical mode splitting in the linear, weak-probe regime.

physics.optics

Community Report from the 2025 SNOLAB Future Projects Workshop

SNOLAB hosts a biannual Future Projects Workshop (FPW) with the goal of encouraging future project stakeholders to present ideas, concepts, and needs for experiments or programs that could one day be hosted at SNOLAB. The 2025 FPW was held in the larger context of a 15-year planning exercise requested by the Canada Foundation for Innovation. This report collects input from the community, including both contributions to the workshop and contributions that could not be scheduled in the workshop but nonetheless are important to the community.

hep-ex

Cryogenic Magnomechanics for Thermometry Applications

Cavity magnomechanics combines strong coupling between magnons in a dielectric material and microwave cavity photons with long-lived mechanical resonances. Forming a triple resonance condition, this hybrid quantum system promises many advantages in quantum technologies, yet has never been studied at the cryogenic temperatures required to reveal such quantum properties. We report the observation of magnomechanics at cryogenic temperatures down to \qty9K. The experiment was conducted using a YIG sphere inside a microwave cavity, where we measured both the thermomechanical motion and the temperature-dependence of the magnon linewidth.

cond-mat.other

A continuously-cooled 3He/4He phase separation refrigerator

We present a novel cooling method that uses the phase separation and evaporative cooling of 3He to reach and continuously maintain sub-kelvin temperatures. While less complex than a dilution refrigerator, the system performs similarly to a continuous 3He cryostat but with a simpler design, a more efficient cooldown process, and a significantly smaller 3He requirement. Our prototype demonstrated a base temperature of 585 mK and 3 mW cooling power at 700 mK using just two gaseous liters of 3He. Lower temperatures could be expected in systems with improved heat exchangers and pumping efficiency.

cond-mat.other

Magnon-microwave backaction noise evasion in cavity magnomechanics

In cavity magnomechanical systems, magnetic excitations couple simultaneously with mechanical vibrations and microwaves, incorporating the tunability of magnetism and the long lifetimes of mechanical modes. Applications of such systems, such as thermometry and sensing, require precise measurement of the mechanical degree-of-freedom. In this paper, we propose a scheme for realizing backaction evading measurements of the mechanical vibrations in cavity magnomechanics. Our proposal involves driving the microwave cavity with two tones separated by twice the phonon frequency and with amplitudes satisfying a balance relation. We show that the minimum added imprecision noise is obtained for drives centered around the lower frequency magnon-microwave polaritons, which can beat the standard quantum limit at modest drive amplitudes. Our scheme is a simple and flexible way of engineering backaction evasion measurements that can be further generalized to other multimode systems.

cond-mat.mes-hall

HeLIOS: The Superfluid Helium Ultralight Dark Matter Detector

The absence of a breakthrough in directly observing dark matter (DM) through prominent large-scale detectors motivates the development of novel tabletop experiments probing more exotic regions of the parameter space. If DM contains ultralight bosonic particles, they would behave as a classical wave and could manifest through an oscillating force on baryonic matter that is coherent over $\sim 10^6$ periods. Our Helium ultraLIght dark matter Optomechanical Sensor (HeLIOS) uses the high-$Q$ acoustic modes of superfluid helium-4 to resonantly amplify this signal. A superconducting re-entrant microwave cavity enables sensitive optomechanical readout ultimately limited by thermal motion at millikelvin temperatures. Pressurizing the helium allows for the unique possibility of tuning the mechanical frequency to effectively broaden the DM detection bandwidth. We demonstrate the working principle of our prototype HeLIOS detector and show that future generations of HeLIOS could explore unconstrained parameter space for both scalar and vector ultralight DM after just an hour of integration time.

astro-ph.IM

Magnomechanical backaction corrections due to coupling to higher order Walker modes and Kerr nonlinearities

The radiation pressure-like coupling between magnons and phonons in magnets can modify the phonon frequency (magnomechanical spring effect) and decay rate (magnomechanical decay) via dynamical backaction. Such effects have been recently observed by coupling the uniform magnon mode of a magnetic sphere (the Kittel mode) to a microwave cavity. In particular, the ability to evade backaction effects was demonstrated [C.A. Potts et al., arXiv:2211.13766 [quant-ph] (2022)], a requisite for applications such as magnomechanical based thermometry. However, deviations were observed from the predicted magnomechanical decay rate within the standard theoretical model. In this work, we account for these deviations by considering corrections due to (i) magnetic Kerr nonlinearities and (ii) the coupling of phonons to additional magnon modes. Provided that such additional modes couple weakly to the driven cavity, our model yields a correction proportional to the average Kittel magnon mode occupation. We focus our results on magnetic spheres, where we show that the magnetostatic Walker modes couple to the relevant mechanical modes as efficiently as the Kittel mode. Our model yields excellent agreement with the experimental data.

cond-mat.mes-hall

Dynamical Backaction Evading Magnomechanics

The interaction between magnons and mechanical vibrations dynamically modify the properties of the mechanical oscillator, such as its frequency and decay rate. Known as dynamical backaction, this effect is the basis for many theoretical protocols, such as entanglement generation or mechanical ground-state cooling. However, dynamical backaction is also detrimental for specific applications. Here, we demonstrate the implementation of a cavity magnomechanical measurement that fully evades dynamical backaction effects. Through careful engineering, the magnomechanical scattering rate into the hybrid magnon-photon modes can be precisely matched, eliminating dynamical backaction damping. Backaction evasion is confirmed via the measurement of a drive-power-independent mechanical linewidth.

quant-ph

Surface-dominated finite size effects in nanoconfined superfluid helium

Superfluid $^4$He (He-II) is a widely studied model system for exploring finite-size effects in strongly confined geometries. Here, we study He-II confined in mm-scale channels of 25 and 50 nm height at high pressures using a nanofluidic Helmholtz resonator. We find that the superfluid density is measurably suppressed in the confined geometry from the transition temperature down to 0.6 K. Importantly, this suppression can be accounted for by roton-like thermal excitation with an energy gap of 5 K. We show that the surface-bound excitations lead to the previously unexplained lack of finite-size scaling of suppression of the superfluid density.

cond-mat.mes-hall

Precision measurements of the zero temperature dielectric constant and density of liquid $^4$He

The resonant frequencies of three-dimensional microwave cavities are explicitly dependent on the dielectric constant of the material filling the cavity, making them an ideal system for probing material properties. In particular, dielectric constant measurements allow one to extract the helium density through the Clausius-Mossotti relation. By filling a cylindrical aluminum cavity with superfluid helium, we make precision measurements of the dielectric constant of liquid $^4$He at saturated vapor pressure for range of temperatures 30 -- 300 mK and at pressures of 0-25.0 bar at 30 mK, essentially the zero temperature limit for the properties of $^4$He. After reviewing previous measurements, we find systematic discrepancy between low and high frequency determination of the dielectric constant in the zero-temperature limit and moderate discrepancy with previously reported values of pressure-dependent density. Our precision measurements suggest 3D microwave cavities are a promising choice for refining previously measured values in helium, with potential applications in metrology.

cond-mat.other

Engineering atomic polarization with microwave-assisted optical pumping

Polarized atomic ensembles play a crucial role in precision measurements. We demonstrate a novel method of creating atomic polarization in an alkali vapor in a continuous-wave regime. The method relies on a combination of optical pumping by a laser beam and microwave transitions due to a cavity-enhanced magnetic field. With this approach, atomic internal angular momentum can be oriented along a static magnetic field at an arbitrary angle with respect to the laser beam. Furthermore, the atomic polarization depends on the microwave parameters, which can be used for microwave-to-optical transduction and microwave-controlled nonlinear magneto-optical rotation.

physics.atom-ph

Strong-coupling corrections to hard domain walls in superfluid 3He-B

Domain walls in superfluid 3He-B have gained renewed interest in light of experimental progress on confining helium in nanofabricated geometries. Here, we study the effect of strong-coupling corrections on domain wall width and interfacial tension by determining self-consistent solutions to spatially-dependent Ginzburg-Landau equations. We find that the formation of domain walls is generally energetically favored in strong coupling over weak coupling. Calculations were performed over a wide range of temperatures and pressures, showing decreasing interface energy with increasing temperature and pressure. This has implications for the observability of such domain walls in 3He-B, which are of both fundamental interest and form the basis for spatially-modulated pair-density wave states, when stabilized by strong confinement.

cond-mat.supr-con

Dynamical Backaction Magnomechanics

Dynamical backaction resulting from radiation pressure forces in optomechanical systems has proven to be a versatile tool for manipulating mechanical vibrations. Notably, dynamical backaction has resulted in the cooling of a mechanical resonator to its ground-state, driving phonon lasing, the generation of entangled states, and observation of the optical-spring effect. In certain magnetic materials, mechanical vibrations can interact with magnetic excitations (magnons) via the magnetostrictive interaction, resulting in an analogous magnon-induced dynamical backaction. In this article, we directly observe the impact of magnon-induced dynamical backaction on a spherical magnetic sample's mechanical vibrations. Moreover, dynamical backaction effects play a crucial role in many recent theoretical proposals; thus, our work provides the foundation for future experimental work pursuing many of these theoretical proposals.

cond-mat.mes-hall

Prototype Superfluid Gravitational Wave Detector

We study a cross-shaped cavity filled with superfluid $^4$He as a prototype resonant-mass gravitational wave detector. Using a membrane and a re-entrant microwave cavity as a sensitive optomechanical transducer, we were able to observe the thermally excited high-$Q$ acoustic modes of the helium at 20 mK temperature and achieved a strain sensitivity of $8 \times 10^{-19}$ Hz$^{-1/2}$ to gravitational waves. To facilitate the broadband detection of continuous gravitational waves, we tune the kilohertz-scale mechanical resonance frequencies up to 173 Hz/bar by pressurizing the helium. With reasonable improvements, this architecture will enable the search for GWs in the 1-30 kHz range, relevant for a number of astrophysical sources both within and beyond the Standard Model.

gr-qc

Strong magnon-photon coupling within a tunable cryogenic microwave cavity

The ability to achieve strong-coupling has made cavity-magnon systems an exciting platform for the development of hybrid quantum systems and the investigation of fundamental problems in physics. Unfortunately, current experimental realizations are constrained to operate at a single frequency, defined by the geometry of the microwave cavity. In this article we realize a highly-tunable, cryogenic, microwave cavity strongly coupled to magnetic spins. The cavity can be tuned in situ by up to 1.5 GHz, approximately 15% of its original 10 GHz resonance frequency. Moreover, this system remains within the strong-coupling regime at all frequencies with a cooperativity of approximately 800.

physics.app-ph

Observation of bistable turbulence in quasi-two-dimensional superflow

Turbulent flow restricted to two dimensions can spontaneously develop order on large scales, defying entropy expectations and in sharp contrast with turbulence in three dimensions where nonlinear turbulent processes act to destroy large-scale order. In this work we report the observation of unusual turbulent behavior in steady-state flow of superfluid \4He---a liquid with vanishing viscosity and discrete vorticity---in a nearly two-dimensional channel. Surprisingly, for a range of experimental parameters, turbulence is observed to exist in two bistable states. This bistability can be well explained by the appearance of large-scale regions of flow of opposite vorticity.

cond-mat.other

Wavelength transduction from a 3D microwave cavity to telecom using piezoelectric optomechanical crystals

Microwave to optical transduction has received a great deal of interest from the cavity optomechanics community as a landmark application for electro-optomechanical systems. In this Letter, we demonstrate a novel transducer that combines high-frequency mechanical motion and a microwave cavity for the first time. The system consists of a 3D microwave cavity and a gallium arsenide optomechanical crystal, which has been placed in the microwave electric field maximum. This allows the microwave cavity to actuate the gigahertz-frequency mechanical breathing mode in the optomechanical crystal through the piezoelectric effect, which is then read out using a telecom optical mode. The gallium arsenide optomechanical crystal is a good candidate for low-noise microwave-to-telecom transduction, as it has been previously cooled to the mechanical ground state in a dilution refrigerator. Moreover, the 3D microwave cavity architecture can naturally be extended to couple to superconducting qubits and to create hybrid quantum systems.

cond-mat.mes-hall