Searcharxiv⌕ Search

arXiv subjects

J. Puimedón

Publications and source records attributed to J. Puimedón.

At least 19 recordsLinked to original sources

First Experimental Bounds on Transverse Plasmon Solar Axions with ANAIS-112

Solar axion-like particles (ALPs) can be resonantly produced through the conversion of transverse plasmons in the magnetic field of the solar interior, introducing a production mechanism complementary to the conventional Primakoff process. In this Letter, we report the first experimental search for solar ALPs produced through this mechanism. Using an exposure of 625.75 kg$\times$yr from ANAIS-112, we search for the annual modulation of the flux induced by the variation of the Earth--Sun distance, assuming detection through inverse Primakoff conversion in the detector. Modulation amplitudes fitted in 1 keV bins between 1--20 keV are consistent with the absence of modulation, yielding the first constraints on the axion--photon coupling that include the resonant transverse-plasmon flux, $g_{aγ} < 1.32\times 10^{-9} \mathrm{GeV}^{-1}$ (90\% C.L.) at $m_a \simeq 150$ eV. This previously unexplored production channel extends the sensitivity of ANAIS-112 in the mass range 35--280 eV, where, for the expected solar magnetic-field models, the transverse-plasmon flux exceeds the Primakoff flux by up to two orders of magnitude.

hep-ex↗

Status of the HENSA collaboration at the Canfranc Underground Laboratory: results from two years of measurement of the neutron flux in hall B

Thiswork deals with the characterization of the neutron flux in hall B of the CanfrancUnderground Laboratory (LSC) employing the High Efficiency Neutron Spectrometry Array (HENSA). The ultimate goal of this measurement is to set a limit on the corresponding effects of the neutron flux in the background of the ANAIS-112 experiment. The preliminary neutron counting rates of two years of measurement are reported. Various data analysis techniques, including pulse shape discrimination, are discussed. The first results on the spectral reconstruction of the neutron flux are also presented.

physics.ins-det↗

Combined Annual Modulation Dark Matter Search with COSINE-100 and ANAIS-112

The annual modulation signal, claimed to be consistent with dark matter as observed by DAMA/LIBRA in a sodium-iodide based detector, has persisted for over two decades. COSINE-100 and ANAIS-112 were designed to test the claim directly using the same target material. COSINE-100, located at Yangyang Underground Laboratory in South Korea, and ANAIS-112, located at Canfranc Underground Laboratory in Spain, have been taking data since 2016 and 2017, respectively. Each experiment published its respective results independently. In this paper, we present the results of an annual modulation search as a test of the signal observed by DAMA/LIBRA with the first three respective years of data from COSINE-100 and ANAIS-112. Using a Markov Chain Monte Carlo method, we find best fit values for modulation amplitude of $-0.0002 {\pm} 0.0026$ cpd/kg/keV in the 1-6 keV and $0.0021 {\pm} 0.0028$ cpd/kg/keV in the 2-6 keV energy regions. These results are not compatible with DAMA/LIBRA's assertion for their observation of annual modulation at $3.7σ$ and $2.6σ$, respectively. Performing a simple combination of the newly released 6-years datasets from both experiments find values consistent with no modulation at $0.0005 {\pm} 0.0019$ cpd/kg/keV in the 1-6 keV and $0.0027 {\pm} 0.0021$ cpd/kg/keV in the 2-6 keV energy regions with $4.68σ$ and $3.53σ$ respective exclusions of the DAMA/LIBRA signal.

astro-ph.IM↗

Neutron calibrations in dark matter searches: the ANAIS-112 case

ANAIS is a direct dark matter detection experiment whose goal is to confirm or refute in a model independent way the positive annual modulation signal claimed by DAMA/LIBRA. Consisting of 112.5 kg of NaI(Tl) scintillators, ANAIS-112 is taking data at the Canfranc Underground Laboratory in Spain since August, 2017. Results corresponding to the analysis of three years of data are compatible with the absence of modulation and incompatible with DAMA/LIBRA. However, testing this signal relies on the knowledge of the scintillation quenching factors (QF), which measure the relative efficiency for the conversion into light of the nuclear recoil energy with respect to the same energy deposited by electrons. Previous measurements of the QF in NaI(Tl) show a large dispersion. Consequently, in order to better understand the response of the ANAIS-112 detectors to nuclear recoils, a specific neutron calibration program has been developed. This program combines two different approaches: on the one hand, QF measurements were carried out in a monoenergetic neutron beam; on the other hand, the study presented here aims at the evaluation of the QF by exposing directly the ANAIS-112 crystals to neutrons from low activity $^{252}$Cf sources, placed outside the lead shielding. Comparison between these onsite neutron measurements and detailed GEANT4 simulations will be presented, confirming that this approach allows testing different QF models.

astro-ph.IM↗

Improving ANAIS-112 sensitivity to DAMA/LIBRA signal with machine learning techniques

The DAMA/LIBRA observation of an annual modulation in the detection rate compatible with that expected for dark matter particles from the galactic halo has accumulated evidence for more than twenty years. It is the only hint of a direct detection of the elusive dark matter, but it is in strong tension with the negative results of other very sensitive experiments, requiring ad-hoc scenarios to reconcile all the present experimental results. Testing the DAMA/LIBRA result using the same target material, NaI(Tl), removes the dependence on the particle and halo models and is the goal of the ANAIS-112 experiment, taking data at the Canfranc Underground Laboratory in Spain since August 2017 with 112.5 kg of NaI(Tl). At very low energies, the detection rate is dominated by non-bulk scintillation events and careful event selection is mandatory. This article summarizes the efforts devoted to better characterize and filter this contribution in ANAIS-112 data using a boosted decision tree (BDT), trained for this goal with high efficiency. We report on the selection of the training populations, the procedure to determine the optimal cut on the BDT parameter, the estimate of the efficiencies for the selection of bulk scintillation in the region of interest (ROI), and the evaluation of the performance of this analysis with respect to the previous filtering. The improvement achieved in background rejection in the ROI, but moreover, the increase in detection efficiency, push the ANAIS-112 sensitivity to test the DAMA/LIBRA annual modulation result around 3$σ$ with three-year exposure, being possible to reach 5$σ$ by extending the data taking for a few more years than the scheduled 5 years which were due in August 2022.

astro-ph.IM↗

Long term measurement of the $^{222}$Rn concentration in the Canfranc Underground Laboratory

We report the results of six years (2013-2018) of measurements of $^{222}$Rn air concentration, relative humidity, atmospheric pressure and temperature in the halls A, B and C of the Canfranc Underground Laboratory (LSC). We have calculated all the Pearson correlation coefficients among these parameters and we have found a positive correlation between the $^{222}$Rn concentration and the relative humidity. Both correlated variables show a seasonal periodicity. The joint analysis of laboratory data and four years (2015-2018) of the meteorological variables outside the laboratory shows the correlation between the $^{222}$Rn concentration and the outside temperature. The collected information stresses the relevance of designing good Rn-mitigation strategies in current and future experiments at LSC; in particular, we have checked for two years (2017-2018) the good performance of the mitigation procedure of the ANAIS--112 experiment. Finally, in another measurement (2019-2021) for two years of live time, we report an upper limit to the residual $^{222}$Rn content of the radon-free air provided by the radon abatement system installed in the laboratory.

physics.ins-det↗

Machine-learning techniques applied to three-year exposure of ANAIS-112

ANAIS is a direct dark matter detection experiment aiming at the confirmation or refutation of the DAMA/LIBRA positive annual modulation signal in the low energy detection rate, using the same target and technique. ANAIS-112, located at the Canfranc Underground Laboratory in Spain, is operating an array of 3$\times$3 ultrapure NaI(Tl) crystals with a total mass of 112.5 kg since August 2017. The trigger rate in the region of interest (1-6 keV) is dominated by non-bulk scintillation events. In order to discriminate these noise events from bulk scintillation events, robust filtering protocols have been developed. Although this filtering procedure works very well above 2 keV, the measured rate from 1 to 2 keV is about 50% higher than expected according to our background model, and we cannot discard non-bulk scintillation events as responsible of that excess. In order to improve the rejection of noise events, a Boosted Decision Tree has been developed and applied. With this new PMT-related noise rejection algorithm, the ANAIS-112 background between 1 and 2 keV is reduced by almost 30%, leading to an increase in sensitivity to the annual modulation signal. The reanalysis of the three years of ANAIS-112 data with this technique is also presented.

astro-ph.IM↗

ANAIS-112 status: two years results on annual modulation

ANAIS (Annual modulation with NaI Scintillators) is a dark matter direct detection experiment located at the Canfranc Underground Laboratory (LSC), in Spain. The goal is to confirm or refute in a model independent way the DAMA/LIBRA positive result: an annual modulation in the low-energy detection rate compatible with the expected signal induced by dark matter particles in the galactic halo. This signal, observed for about 20 years, is in strong tension with the negative results of other very sensitive experiments, but a direct comparison using the same target material, NaI(Tl), was still lacking. ANAIS-112, consisting of 112.5 kg of NaI(Tl) scintillators, is taking data at the LSC since August 2017. Here we present the preliminary annual modulation analysis corresponding to two years of data (exposure of 220.69 kg x y) and the ANAIS-112 projected sensitivity for the scheduled 5 y of operation.

astro-ph.IM↗

Performance of ANAIS-112 experiment after the first year of data taking

ANAIS is a direct detection dark matter experiment aiming at the study of the annual modulation expected in the interaction rate. It uses same target and technique than DAMA/LIBRA experiment, which reported a highly significant positive modulation compatible with that expected for dark matter particles distributed in the galactic halo. However, other very sensitive experiments do not find any hint of particles with the required properties, although comparison is model dependent. In 2017, ANAIS-112 experiment was installed at the Canfranc Underground Laboratory (LSC), in Spain, and after the commissioning run for calibration and general assessment, ANAIS-112 started data taking in dark matter mode on August 3$^{rd}$, 2017. It consists of nine NaI(Tl) modules, amounting 112.5 kg of mass in total. ANAIS-112 will be able to test the DAMA/LIBRA result with the achieved background and threshold at three sigma level in five years of data taking. Here we report on the experimental apparatus and detector performance after the first year of data taking. Total live time available amounts to 341.72 days, being the corresponding exposure 105.32 kg x yr.

astro-ph.IM↗

ANAIS-112 sensitivity in the search for dark matter annual modulation

The annual modulation measured by the DAMA/LIBRA experiment can be explained by the interaction of dark matter WIMPs in NaI(Tl) scintillator detectors. Other experiments, with different targets or techniques, exclude the region of parameters singled out by DAMA/LIBRA, but the comparison of their results relies on several hypotheses regarding the dark matter model. ANAIS-112 is a dark matter search with 112.5 kg of NaI(Tl) scintillators at the Canfranc Underground Laboratory (LSC) to test the DAMA/LIBRA result in a model independent way. We analyze its prospects in terms of the a priori critical and detection limits of the experiment. A simple figure of merit has been obtained to compare the different experiments looking for the annual modulation observed by DAMA/LIBRA. We conclude that after 5 years of measurement, ANAIS-112 can detect the annual modulation in the 3$σ$ region compatible with the DAMA/LIBRA result.

astro-ph.IM↗

First results on dark matter annual modulation from ANAIS-112 experiment

ANAIS is a direct detection dark matter experiment aiming at the testing of the DAMA/LIBRA annual modulation result, which standing for about two decades has neither been confirmed nor ruled out by any other experiment in a model independent way. ANAIS-112, consisting of 112.5 kg of sodium iodide crystals, is taking data at the Canfranc Underground Laboratory, Spain, since August 2017. This letter presents the annual modulation analysis of 1.5 years of data, amounting to 157.55 kg$\times$y. We focus on the model independent analysis searching for modulation and the validation of our sensitivity prospects. ANAIS-112 data are consistent with the null hypothesis (p-values of 0.65 and 0.16 for [2-6] and [1-6] keV energy regions, respectively). The best fits for the modulation hypothesis are consistent with the absence of modulation ($S_m$=-0.0044$\pm$0.0058 cpd/kg/keV and -0.0015$\pm$0.0063 cpd/kg/keV, respectively). They are in agreement with our estimated sensitivity for the accumulated exposure, supporting our projected goal of reaching a 3$σ$ sensitivity to the DAMA/LIBRA result in 5 years of data taking.

astro-ph.IM↗

Annual modulation of dark matter: The ANAIS-112 case

The annual modulation measured by the DAMA/LIBRA experiment can be explained by the interaction of dark matter WIMPs in NaI(Tl) scintillator detectors. Other experiments, with different targets or techniques, exclude the region of parameters singled out by DAMA/LIBRA, but the comparison of their results relies on several hypotheses regarding the dark matter model. ANAIS-112 is a dark matter search with 112.5 kg of NaI(Tl) scintillators under commissioning at the Canfranc Underground Laboratory (LSC) to test the DAMA/LIBRA result in a model independent way. We analyze its prospects in terms of the a priori critical and detection limits of the experiment. The analysis is based on the detector response and the background level measured for the first modules operated in Canfranc.

astro-ph.IM↗

Light yield determination in large sodium iodide detectors applied in the search for dark matter

Application of NaI(Tl) detectors in the search for galactic dark matter particles through their elastic scattering off the target nuclei is well motivated because of the long standing DAMA/LIBRA highly significant positive result on annual modulation, still requiring confirmation. For such a goal, it is mandatory to reach very low threshold in energy (at or below the keV level), very low radioactive background (at a few counts/keV/kg/day), and high detection mass (at or above the 100 kg scale). One of the most relevant technical issues is the optimization of the crystal intrinsic scintillation light yield and the efficiency of the light collecting system for large mass crystals. In the frame of the ANAIS (Annual modulation with NaI Scintillators) dark matter search project large NaI(Tl) crystals from different providers coupled to two photomultiplier tubes (PMTs) have been tested at the Canfranc Underground Laboratory. In this paper we present the estimates of the NaI(Tl) scintillation light collected using full-absorption peaks at very low energy from external and internal sources emitting gammas/electrons, and single-photoelectron events populations selected by using very low energy pulses tails. Outstanding scintillation light collection at the level of 15~photoelectrons/keV can be reported for the final design and provider chosen for ANAIS detectors. Taking into account the Quantum Efficiency of the PMT units used, the intrinsic scintillation light yield in these NaI(Tl) crystals is above 40~photoelectrons/keV for energy depositions in the range from 3 up to 25~keV. This very high light output of ANAIS crystals allows triggering below 1~keV, which is very important in order to increase the sensitivity in the direct detection of dark matter.

physics.ins-det↗

The ANAIS Dark Matter Project: Status and Prospects

The ANAIS (Annual modulation with NaI(Tl) Scintillators) experiment aims at the confirmation of the DAMA/LIBRA positive annual modulation signal using the same target and technique at the Canfranc Underground Laboratory (LSC). A first step, named ANAIS-25 (two 12.5 kg NaI(Tl) modules) taking data from December 2012 to February 2015, provided interesting outcomes: very high light collection efficiency, that could allow to lower the analysis energy threshold down to the level of 1 keVee, and a good understanding of the different background components, in particular the cosmogenic activated isotopes in the crystal bulk and other radioactive contaminations of the NaI crystal/powder. But those prototypes clearly pointed to the need for improved crystal radiopurity, in particular for $^{210}$Pb contamination. Since then, improvements in the purification and growing procedures in order to reduce background in the very low energy region have been implemented and a new 12.5 kg module has been constructed and installed between the former two crystals, forming the ANAIS-37 setup. Very preliminary results of this setup evidence the improvement on radiopurity of the new crystal and are presented here. In addition, background simulations and prospects for the full experiment are discussed.

astro-ph.IM↗

Status of the ANAIS Dark Matter Project at the Canfranc Underground Laboratory

The ANAIS (Annual modulation with NaI(Tl) Scintillators) experiment aims at the confirmation of the DAMA/LIBRA signal using the same target and technique at the Canfranc Underground Laboratory (LSC). Along 2016, 112.5 kg of ultra pure NaI(Tl) crystals will be installed at LSC in a 3x3 modules matrix configuration. The ANAIS-25 and ANAIS-37 set-ups have been taking data at the LSC testing the detector performance, the DAQ and analysis systems, and assessing the background. Main results coming from both set-ups will be summarized in this paper, focusing on the excellent detector performance and background understanding. Prospects for the experiment will be also briefly revised.

astro-ph.IM↗

Background analysis and status of the ANAIS dark matter project

ANAIS (Annual modulation with NaI Scintillators) is a project aiming to set up at the new facilities of the Canfranc Underground Laboratory (LSC), a large scale NaI(Tl) experiment in order to explore the DAMA/LIBRA annual modulation positive result using the same target and technique. Two 12.5 kg each NaI(Tl) crystals provided by Alpha Spectra took data at the LSC in the ANAIS-25 set-up. The comparison of the background model for the ANAIS-25 prototypes with the experimental results is presented. ANAIS crystal radiopurity goals have been achieved for Th-232 and U-238 chains, but a Pb-210 contamination out-of-equilibrium was identified, whose origin has been studied. The high light collection efficiency obtained with these prototypes allows to anticipate an energy threshold of the order of 1 keVee. A new detector, with improved performances, was received in March 2015 and very preliminary results are shown.

astro-ph.IM↗

Cosmogenic radionuclide production in NaI(Tl) crystals

The production of long-lived radioactive isotopes in materials due to the exposure to cosmic rays on Earth surface can be an hazard for experiments demanding ultra-low background conditions, typically performed deep underground. Production rates of cosmogenic isotopes in all the materials present in the experimental set-up, as well as the corresponding cosmic rays exposure history, must be both well known in order to assess the relevance of this effect in the achievable sensitivity of a given experiment. Although NaI(Tl) scintillators are being used in experiments aiming at the direct detection of dark matter since the first nineties of the last century, very few data about cosmogenic isotopes production rates have been published up to date. In this work we present data from two 12.5 kg NaI(Tl) detectors, developed in the frame of the ANAIS project, which were installed inside a convenient shielding at the Canfranc Underground Laboratory just after finishing surface exposure to cosmic rays. The very fast start of data taking allowed to identify and quantify isotopes with half-lives of the order of tens of days. Initial activities underground have been measured and then production rates at sea level have been estimated following the history of detectors; values of about a few tens of nuclei per kg and day for Te isotopes and 22Na and of a few hundreds for I isotopes have been found. These are the first direct estimates of production rates of cosmogenic nuclides in NaI crystals. A comparison of the so deduced rates with calculations using typical cosmic neutron flux at sea level and a carefully selected description of excitation functions will be also presented together with an estimate of the corresponding contribution to the background at low and high energies, which can be relevant for experiments aiming at rare events searches.

physics.ins-det↗

Bulk NaI(Tl) scintillation low energy events selection with the ANAIS-0 module

Dark matter particles scattering off some target nuclei are expected to deposit very small energies in form of nuclear recoils (below 100 keV). Because of the low scintillation efficiency for nuclear recoils vs. electron recoils, in most of the scintillating targets considered in the search for dark matter, the region below 10 keVee concentrates most of the expected dark matter signal. For this reason, very low energy threshold (at or below 2 keVee) and very low background are required. This is the case of the ANAIS (Annual modulation with NaI Scintillators) experiment. A good knowledge of the detector response function for real scintillation events, a good characterization of other anomalous or noise event populations contributing in that energy range, and the development of convenient filtering procedures for the latter are mandatory to achieve the required low background at such a low energy. In this work we will present the specific protocols developed to select bulk scintillation events in NaI(Tl), and its application to data obtained with the ANAIS-0 prototype. Slight differences in time constants are expected in scintillation pulses produced by nuclear or electron recoils in NaI(Tl), so in order to analyze the effect of these filtering procedures in the case of a recoil population attributable to dark matter, data from a neutron calibration have been used.

astro-ph.IM↗