SearcharxivSearch

arXiv subjects

J. Ramsey

Publications and source records attributed to J. Ramsey.

16 recordsLinked to original sources

Measurement of the Neutron Cross Section on Argon Between 95 and 720 MeV

We report an extended measurement of the neutron cross section on argon in the energy range of 95-720 MeV. The measurement was obtained with a 4.3-hour exposure of the Mini-CAPTAIN detector to the WNR/LANSCE beam at LANL. Compared to an earlier analysis of the same data, this extended analysis includes a reassessment of systematic uncertainties, in particular related to unused wires in the upstream part of the detector. Using this information we doubled the fiducial volume in the experiment and increased the statistics by a factor of 2.4. We also shifted the analysis from energy bins to time-of-flight bins. This change reduced the overall considered energy range, but improved the understanding of the energy spectrum of incoming neutrons in each bin. Overall, the new measurements are extracted from a fit to the attenuation of the neutron flux in five time-of-flight regions: 140 ns - 180 ns, 120 ns - 140 ns, 112 ns - 120 ns, 104 ns - 112 ns, 96 ns - 104 ns. The final cross sections are given for the flux-averaged energy in each time-of-flight bin: $σ(146~\rm{MeV})=0.60^{+0.14}_{-0.14}\pm0.08$(syst) b, $σ(236~\rm{MeV})=0.72^{+0.10}_{-0.10}\pm0.04$(syst) b, $σ(319~\rm{MeV})=0.80^{+0.13}_{-0.12}\pm0.040$(syst) b, $σ(404~\rm{MeV})=0.74^{+0.14}_{-0.09}\pm0.04$(syst) b, $σ(543~\rm{MeV})=0.74^{+0.09}_{-0.09}\pm0.04$(syst) b.

nucl-ex

Fill and dump measurement of the neutron lifetime using an asymmetric magneto-gravitational trap

The past two decades have yielded several new measurements and reanalyses of older measurements of the neutron lifetime. These have led to a 4.4 standard deviation discrepancy between the most precise measurements of the neutron decay rate producing protons in cold neutron beams and the lifetime measured in neutron storage experiments. Measurements using different techniques are important for investigating whether there are unidentified systematic effects in any of the measurements. In this paper we report a new measurement using the Los Alamos asymmetric magneto-gravitational trap where the surviving neutrons are counted external to the trap using the fill and dump method. The new measurement gives a free neutron lifetime of . Although this measurement is not as precise, it is in statistical agreement with previous results using in situ counting in the same apparatus.

nucl-ex

Improved neutron lifetime measurement with UCN$τ$

We report an improved measurement of the free neutron lifetime $τ_{n}$ using the UCN$τ$ apparatus at the Los Alamos Neutron Science Center. We counted a total of approximately $38\times10^{6}$ surviving ultracold neutrons (UCN) after storing in UCN$τ$'s magneto-gravitational trap over two data acquisition campaigns in 2017 and 2018. We extract $τ_{n}$ from three blinded, independent analyses by both pairing long and short storage-time runs to find a set of replicate $τ_{n}$ measurements and by performing a global likelihood fit to all data while self-consistently incorporating the $β$-decay lifetime. Both techniques achieve consistent results and find a value $τ_{n}=877.75\pm0.28_{\text{ stat}}+0.22/-0.16_{\text{ syst}}$~s. With this sensitivity, neutron lifetime experiments now directly address the impact of recent refinements in our understanding of the standard model for neutron decay.

nucl-ex

The Mini-CAPTAIN Liquid Argon Time Projection Chamber

This manuscript describes the commissioning of the Mini-CAPTAIN liquid argon detector in a neutron beam at the Los Alamos Neutron Science Center (LANSCE), which led to a first measurement of high-energy neutron interactions in argon. The Mini-CAPTAIN detector consists of a Time Projection Chamber (TPC) with an accompanying photomultiplier tube (PMT) array sealed inside a liquid-argon-filled cryostat. The liquid argon is constantly purified and recirculated in a closed-loop cycle during operation. The specifications and assembly of the detector subsystems and an overview of their performance in a neutron beam are reported.

physics.ins-det

The Nab Experiment: A Precision Measurement of Unpolarized Neutron Beta Decay

Neutron beta decay is one of the most fundamental processes in nuclear physics and provides sensitive means to uncover the details of the weak interaction. Neutron beta decay can evaluate the ratio of axial-vector to vector coupling constants in the standard model, $λ= g_A / g_V$, through multiple decay correlations. The Nab experiment will carry out measurements of the electron-neutrino correlation parameter $a$ with a precision of $δa / a = 10^{-3}$ and the Fierz interference term $b$ to $δb = 3\times10^{-3}$ in unpolarized free neutron beta decay. These results, along with a more precise measurement of the neutron lifetime, aim to deliver an independent determination of the ratio $λ$ with a precision of $δλ/ λ= 0.03\%$ that will allow an evaluation of $V_{ud}$ and sensitively test CKM unitarity, independent of nuclear models. Nab utilizes a novel, long asymmetric spectrometer that guides the decay electron and proton to two large area silicon detectors in order to precisely determine the electron energy and an estimation of the proton momentum from the proton time of flight. The Nab spectrometer is being commissioned at the Fundamental Neutron Physics Beamline at the Spallation Neutron Source at Oak Ridge National Lab. We present an overview of the Nab experiment and recent updates on the spectrometer, analysis, and systematic effects.

nucl-ex

The neutron electric dipole moment experiment at the Spallation Neutron Source

Novel experimental techniques are required to make the next big leap in neutron electric dipole moment experimental sensitivity, both in terms of statistics and systematic error control. The nEDM experiment at the Spallation Neutron Source (nEDM@SNS) will implement the scheme of Golub & Lamoreaux [Phys. Rep., 237, 1 (1994)]. The unique properties of combining polarized ultracold neutrons, polarized $^3$He, and superfluid $^4$He will be exploited to provide a sensitivity to $\sim 10^{-28}\,e{\rm \,\cdot\, cm}$. Our cryogenic apparatus will deploy two small ($3\,{\rm L}$) measurement cells with a high density of ultracold neutrons produced and spin analyzed in situ. The electric field strength, precession time, magnetic shielding, and detected UCN number will all be enhanced compared to previous room temperature Ramsey measurements. Our $^3$He co-magnetometer offers unique control of systematic effects, in particular the Bloch-Siegert induced false EDM. Furthermore, there will be two distinct measurement modes: free precession and dressed spin. This will provide an important self-check of our results. Following five years of "critical component demonstration," our collaboration transitioned to a "large scale integration" phase in 2018. An overview of our measurement techniques, experimental design, and brief updates are described in these proceedings.

nucl-ex

First Measurement of the Total Neutron Cross Section on Argon Between 100 and 800 MeV

We report the first measurement of the neutron cross section on argon in the energy range of 100-800 MeV. The measurement was obtained with a 4.3-hour exposure of the Mini-CAPTAIN detector to the WNR/LANSCE beam at LANL. The total cross section is measured from the attenuation coefficient of the neutron flux as it traverses the liquid argon volume. A set of 2,631 candidate interactions is divided in bins of the neutron kinetic energy calculated from time-of-flight measurements. These interactions are reconstructed with custom-made algorithms specifically designed for the data in a time projection chamber the size of the Mini-CAPTAIN detector. The energy averaged cross section is $0.91 \pm{} 0.10~\mathrm{(stat.)} \pm{} 0.09~\mathrm{(sys.)}~\mathrm{barns}$. A comparison of the measured cross section is made to the GEANT4 and FLUKA event generator packages.

hep-ex

Monte Carlo Simulations of Trapped Ultracold Neutrons in the UCNτ Experiment

In the UCNτ experiment, ultracold neutrons (UCN) are confined by magnetic fields and the Earth's gravitational field. Field-trapping mitigates the problem of UCN loss on material surfaces, which caused the largest correction in prior neutron experiments using material bottles. However, the neutron dynamics in field traps differ qualitatively from those in material bottles. In the latter case, neutrons bounce off material surfaces with significant diffusivity and the population quickly reaches a static spatial distribution with a density gradient induced by the gravitational potential. In contrast, the field-confined UCN -- whose dynamics can be described by Hamiltonian mechanics -- do not exhibit the stochastic behaviors typical of an ideal gas model as observed in material bottles. In this report, we will describe our efforts to simulate UCN trapping in the UCNτ magneto-gravitational trap. We compare the simulation output to the experimental results to determine the parameters of the neutron detector and the input neutron distribution. The tuned model is then used to understand the phase space evolution of neutrons observed in the UCNτ experiment. We will discuss the implications of chaotic dynamics on controlling the systematic effects, such as spectral cleaning and microphonic heating, for a successful UCN lifetime experiment to reach a 0.01% level of precision.

physics.ins-det

Measurement of the neutron lifetime using an asymmetric magneto- gravitational trap and in situ detection

The precise value of the mean neutron lifetime, $τ_n$, plays an important role in nuclear and particle physics and cosmology. It is a key input for predicting the ratio of protons to helium atoms in the primordial universe and is used to search for new physics beyond the Standard Model of particle physics. There is a 3.9 standard deviation discrepancy between $τ_n$ measured by counting the decay rate of free neutrons in a beam (887.7 $\pm$ 2.2 s) and by counting surviving ultracold neutrons stored for different storage times in a material trap (878.5$\pm$0.8 s). The experiment described here eliminates loss mechanisms present in previous trap experiments by levitating polarized ultracold neutrons above the surface of an asymmetric storage trap using a repulsive magnetic field gradient so that the stored neutrons do not interact with material trap walls and neutrons in quasi-stable orbits rapidly exit the trap. As a result of this approach and the use of a new in situ neutron detector, the lifetime reported here (877.7 $\pm$ 0.7 (stat) +0.4/-0.2 (sys) s) is the first modern measurement of $τ_n$ that does not require corrections larger than the quoted uncertainties.

nucl-ex

A new method for measuring the neutron lifetime using an in situ neutron detector

The neutron lifetime is important in understanding the production of light nuclei in the first minutes after the big bang and it provides basic information on the charged weak current of the standard model of particle physics. Two different methods have been used to measure the neutron lifetime: disappearance measurements using bottled ultracold neutrons and decay rate measurements using neutron beams. The best measurements using these two techniques give results that differ by nearly 4 standard deviations. In this paper we describe a new method for measuring surviving neutrons in neutron lifetime measurements using bottled ultracold neutrons that provides better characterization of systematic uncertainties and enables higher precision than previous measurement techniques. We present results obtained using our method.

nucl-ex

Scale-Free Exponents of Resting State provide a Biomarker for Typical and Atypical Brain Activity

Scale-free networks (SFN) arise from simple growth processes, which can encourage efficient, centralized and fault tolerant communication (1). Recently its been shown that stable network hub structure is governed by a phase transition at exponents (>2.0) causing a dramatic change in network structure including a loss of global connectivity, an increasing minimum dominating node set, and a shift towards increasing connectivity growth compared to node growth. Is this SFN shift identifiable in atypical brain activity? The Pareto Distribution (P(D)~D^-\b{eta}) on the hub Degree (D) is a signature of scale-free networks. During resting-state, we assess Degree exponents across a large range of neurotypical and atypical subjects. We use graph complexity theory to provide a predictive theory of the brain network structure. Results. We show that neurotypical resting-state fMRI brain activity possess scale-free Pareto exponents (1.8 se .01) in a single individual scanned over 66 days as well as in 60 different individuals (1.8 se .02). We also show that 60 individuals with Autistic Spectrum Disorder, and 60 individuals with Schizophrenia have significantly higher (>2.0) scale-free exponents (2.4 se .03, 2.3 se .04), indicating more fractionated and less controllable dynamics in the brain networks revealed in resting state. Finally we show that the exponent values vary with phenotypic measures of atypical disease severity indicating that the global topology of the network itself can provide specific diagnostic biomarkers for atypical brain activity.

q-bio.NC

Storage of ultracold neutrons in the UCN$τ$ magneto-gravitational trap

The UCN$τ$ experiment is designed to measure the lifetime $τ_{n}$ of the free neutron by trapping ultracold neutrons (UCN) in a magneto-gravitational trap. An asymmetric bowl-shaped NdFeB magnet Halbach array confines low-field-seeking UCN within the apparatus, and a set of electromagnetic coils in a toroidal geometry provide a background "holding" field to eliminate depolarization-induced UCN loss caused by magnetic field nodes. We present a measurement of the storage time $τ_{store}$ of the trap by storing UCN for various times, and counting the survivors. The data are consistent with a single exponential decay, and we find $τ_{store}=860\pm19$ s: within $1 σ$ of current global averages for $τ_{n}$. The storage time with the holding field deactiveated is found to be $τ_{store}=470 \pm 160$ s; this decreased storage time is due to the loss of UCN which undergo Majorana spin-flips while being stored. We discuss plans to increase the statistical sensitivity of the measurement and investigate potential systematic effects.

physics.ins-det

The CAPTAIN Detector and Physics Program

The Cryogenic Apparatus for Precision Tests of Argon Interactions with Neutrino (CAP- TAIN) program is designed to make measurements of scientific importance to long-baseline neutrino physics and physics topics that will be explored by large underground detectors. The CAPTAIN detector is a liquid argon TPC deployed in a portable and evacuable cryostat. Five tons of liquid argon are instrumented with a 2,000 channel liquid argon TPC and a photon detection system. Subsequent to the commissioning phase, the detector will collect data in a high-energy neutron beamline that is part of the Los Alamos Neutron Science Center to measure cross-sections of spallation products that are backgrounds to measurements of neutrinos from a supernova burst, cross-sections of events that mimic the electron neutrino appearance signal in long-baseline neutrino physics and neutron signatures to constrain neutrino energy reconstruction in LBNE's long-baseline program. Subsequent to the neutron running, the CAPTAIN detector will be moved to a neutrino source. Two possibilities are an on-axis run in the NuMI beamline at FNAL and a run in the neutrino source produced by the SNS. An on-axis run at NuMI produces more than one million events of interest in a two or three year run at neutrino energies between 1 and 10 GeV - complementary to the MicroBooNE experiment, which will measure similar interactions at a lower energy range - 0.5 to 2 GeV. At the SNS the neutrinos result from the decays stopped positively charged pions and muons yielding a broad spectrum up to 50 MeV. If located close to the spallation target, CAPTAIN can detect several thousand events per year in the same neutrino energy regime where neutrinos from a supernova burst are. Measurements at the SNS yield a first measurement of the cross- section of neutrinos on argon in this important energy regime.

physics.ins-det

The Upscattering of Ultracold Neutrons from the polymer $[C_6 H_{12}]_n$

It is generally accepted that the main cause of ultracold neutron (UCN) losses in storage traps is the upscattering to the thermal energy range by hydrogen adsorbed on the surface of the trap walls. However, the data on which this conclusion is based are poor and contradictory. Here, we report a measurement, performed at the Los Alamos National Laboratory UCN source, of the average energy of the flux of upscattered neutrons after the interaction of UCN with hydrogen bound in semicrystalline polymer PMP (tradename TPX), [C$_{6}$H$_{12}$]$_n$. Our analysis, performed with the MCNP code based on the application of the neutron scattering law to UCN upscattered by bound hydrogen in semicrystalline polyethylene, [C$_{2}$H$_{4}$]$_n$, leads us to a flux average energy value of 26$\pm3$ meV in contradiction with previously reported experimental values of 10 to 13 meV and in agreement with the theoretical models of neutron heating implemented in the MCNP code.

cond-mat.mtrl-sci

Measurements of ultracold neutron upscattering and absorption in polyethylene and vanadium

The study of neutron cross sections for elements used as efficient ``absorbers'' of ultracold neutrons (UCN) is crucial for many precision experiments in nuclear and particle physics, cosmology and gravity. In this context, ``absorption'' includes both the capture and upscattering of neutrons to the energies above the UCN energy region. The available data, especially for hydrogen, do not agree between themselves or with the theory. In this report we describe measurements performed at the Los Alamos National Laboratory UCN facility of the UCN upscattering cross sections for vanadium and for hydrogen in CH$_2$ using simultaneous measurements of the radiative capture cross sections for these elements. We measured $σ_{up}=1972\pm130$ b for hydrogen in CH$_2$, which is below theoretical expectations, and $σ_{up} < 25\pm9$ b for vanadium, in agreement with the expectation for the neutron heating by thermal excitations in solids.

nucl-ex

Effect of an electric field on superfluid helium scintillation produced by alpha-particle sources

We report a study of the intensity and time dependence of scintillation produced by weak alpha particle sources in superfluid helium in the presence of an electric field (0 - 45 kV/cm) in the temperature range of 0.2 K to 1.1 K at the saturated vapor pressure. Both the prompt and the delayed components of the scintillation exhibit a reduction in intensity with the application of an electric field. The reduction in the intensity of the prompt component is well approximated by a linear dependence on the electric field strength with a reduction of 15% at 45 kV/cm. When analyzed using the Kramers theory of columnar recombination, this electric field dependence leads to the conclusion that roughly 40% of the scintillation results from species formed from atoms originally promoted to excited states and 60% from excimers created by ionization and subsequent recombination with the charges initially having a cylindrical Gaussian distribution about the alpha track of 60 nm radius. The intensity of the delayed component of the scintillation has a stronger dependence on the electric field strength and on temperature. The implications of these data on the mechanisms affecting scintillation in liquid helium are discussed.

nucl-ex