SearcharxivSearch

arXiv subjects

J. Rodriguez Martino

Publications and source records attributed to J. Rodriguez Martino.

4 recordsLinked to original sources

The Absolute, Relative and Multi-Wavelength Calibration of the Pierre Auger Observatory Fluorescence Detectors

Absolute calibration of the Pierre Auger Observatory fluorescence detectors uses a 375 nm light source at the telescope aperture. This end-to-end technique accounts for the combined effects of all detector components in a single measurement. The relative response has been measured at wavelengths of 320, 337, 355, 380 and 405 nm, defining a spectral response curve which has been normalized to the absolute calibration. Before and after each night of data taking a relative calibration of the phototubes is performed. This relative calibration is used to track both short and long term changes in the detector's response. A cross check of the calibration in some phototubes is performed using an independent laser technique. Overall uncertainties, current results and future plans are discussed.

astro-ph

Optical Relative Calibration and Stability Monitoring for the Auger Fluorescence Detector

The stability of the fluorescence telescopes of the Pierre Auger Observatory is monitored with the optical relative calibration setup. Optical fibers distribute light pulses to three different diffuser groups within the optical system. The total charge per pulse is measured for each pixel and compared with reference calibration measurements. This allows monitoring the short and long term stability with respect of the relative timing between pixels and the relative gain for each pixel. The designs of the LED calibration unit (LCU) and of the Xenon flash lamp used for relative calibration, are described and their capabilities to monitor the stability of the telescope performances are studied. We report the analysis of relative calibration data recorded during 2004. Fluctuations in the relative calibration constants provide a measure of the stability of the FD.

astro-ph

Quality studies of the data taking conditions for the Auger Fluorescence Detector

As more than half of the Fluorescence Detector (FD) of the Auger Observatory is completed, data taking is becoming a routine job. It is then necessary to follow strict procedures to assure the quality of the data. An overview of the data taking methods is given. The nature of the FD background signal is due to the night sky brightness (stars and planet faint light, moonlight, twilight, airglow, zodiacal and artificial light) and to the electronic background (photomultiplier and electronic noise). The analysis of the fluctuations in the FADC signal (variance analysis), directly proportional to the background mean light level, performed for each night of data taking is used to monitor the FD background signal. The data quality is analysed using different techniques, described in detail. Examples of trigger rates, number of stereo events, dead time due to moonlight, weather or hardware problems are given. The analysis comprises several months of data taking, giving an overview of the FD capabilities, performance and allowing a systematic study of data and their correlation with the environment.

astro-ph

A Water Tank Cerenkov Detector for Very High Energy Astroparticles

Extensive airshower detection is an important issue in current astrophysics endeavours. Surface arrays detectors are a common practice since they are easy to handle and have a 100% duty cycle. In this work we present an experimental study of the parameters relevant to the design of a water Cerenkov detector for high energy airshowers. This detector is conceived as part of the surface array of the Pierre Auger Project, which is expected to be sensitive to ultra high energy cosmic rays. In this paper we focus our attention in the geometry of the tank and its inner liner material, discussing pulse shapes and charge collections.

hep-ex