SearcharxivSearch

arXiv subjects

J. Samarati

Publications and source records attributed to J. Samarati.

15 recordsLinked to original sources

Optical readout of MPGDs with solid wavelength shifters

Optical readout of MicroPattern Gaseous Detectors (MPGDs) makes use of the high granularity of imaging sensors to achieve good spatial resolution for radiation imaging and particle detection. CF4 is widely used as a scintillating gas because its emission lies in the visible range, where optical sensors are most sensitive. However, to reduce reliance on greenhouse gas, such as CF4, which also has limited availability, alternative gas mixtures emitting scintillation light in the ultraviolet range can be used in combination with wavelength shifters. We investigate the spatial resolution achievable with optically read out Gaseous Electron Multipliers (GEMs) and Micromegas when using solid wavelength shifter layers such as Tetraphenyl butadiene (TPB). TPB coatings on the anode of glass Micromegas achieve the best spatial resolution of 0.22 mm owing to the minimal distance between the origin of the scintillation light and the wavelength shifter. Nevertheless, TPB layers were also shown to achieve moderate spatial resolution in combination with optically read out GEMs.

physics.ins-det

Measurements of enriched 155 Gd and 157Gd converters with the NMX detector on the nTOF EAR2 beam line at CERN

The detectors for the NMX instrument at the European Spallation Source (ESS) in Lund use natural Gd as the neutron converter. In 2024, beam time was obtained at the neutron time-of flight experiment (nTOF) at CERN to study the feasibility of an upgrade to enriched Gd. A 10 x 10 cm^2 prototype of the NMX detector was equipped with two enriched Gd samples (157Gd and 155Gd) that were attached with copper tape to the natural Gd cathode of the detector. Three sets of measurements were taken, with the beam focused on either the natural Gd, the 157Gd, or the 155Gd samples. Using the time-of-flight technique with the subsequent conversion of time-of-flight into energy, the resonant region between 1 eV and 200 eV of the 157Gd and 155Gd cross sections was studied. The peaks in the resonant region were clearly visible, having higher ADC values in the ADC spectrum. Additionally, the resonant peaks had a larger number of counts per energy bin. In the thermal neutron energy range, the count rate at the center of the beam was measured for natural Gd, 157Gd, and 155Gd. Enriched 157Gd showed an efficiency that was between 60 - 180% higher, compared to natural Gd, for neutron wavelengths between 0.8 A and 1.8 A. The measured 60 % increase in efficiency at 1.8 A is lower than expected from simulations (100 %) and previous measurements with solid state detectors (80 %). Gamma background detection, bad focusing, and saturation effects most likely explain this deviation. An upgrade of the natural Gd converter to enriched 157Gd would thus lead to an efficiency increase of at least 60 %. The measurements presented in this paper are the first successful time-of-flight measurements with the NMX detector prototype and the ESS VMM readout.

physics.ins-det

Embedding the Timepix4 in Micro-Pattern Gaseous Detectors

The combination of Micro-Pattern Gaseous Detectors (MPGDs) and pixel charge readout enables specific experimental opportunities. Using the Timepix4 for the readout is advantageous because of its size (around 7 cm^2 active area) and its Through Silicon Vias. The latter enables to connect to the Timepix4 from the back side. Thus, it can be tiled on four sides, allowing it to cover large areas without loss of active area. Here, the first results of reading out MPGDs with the Timepix4 are presented. Measurements with a Gas Electron Multiplier (GEM) detector show that event selection based on geometrical parameters of the interaction is possible, X-ray imaging studies can be performed, as well as energy and time-resolved measurements. In parallel, the embedding of a Timepix4 into a micro-resistive Well (uRWell) amplification structure is explored. The first mechanical tests have been successful. The status of the electrical functionality is presented, as well as simulation studies on the signal induction in such a device.

physics.ins-det

Application of the VMM3a/SRS: A t0-less TWIN GEM-based TPC

Integrating the ATLAS/BNL VMM3a ASIC (Application Specific Integrated Circuit) into the RD51/SRS (Scalable Readout System) provides a self-triggered continuous readout system for various gaseous detectors. Since the system allows flexible parameters, such as switching the polarity, adjusting electronics gain or different peaking times, the settings can be adjusted for a wide range of detectors. The system allows particles to be recorded with a MHz interaction rate in energy, space, and time. The system will be introduced in the beginning, and short examples will be given for different applications. After, the Twin GEM TPC will be discussed in more detail to show the benefits of such a trigger-less system in combination with the Twin configuration. Last, a few results for the tracking performance and the possibility to operate as a tracking telescope will be shown. Thus, this presents the possibility of an extremely low material budget tracking system suitable for tracking from high to low-energy particle beams.

physics.ins-det

The Ultra-Low material budget GEM based TPC for tracking with VMM3a readout

The Gaseous Electron Multiplier-based Time Projection Chamber (GEM-TPC) in TWIN configuration for particle tracking has been consolidated after extensive investigations in different facilities to study its tracking performance. The most attractive feature of this detector is its ultra-low material budget, which is 0.28\% X/X$_0$ and can be further reduced by decreasing the thickness of the gas traversed by the incident particles. Thus, it provides excellent position reconstruction and reduced multi-scattering. This detector consists of two GEM-TPCs with drift fields in opposite directions, achieved by rotating one 180 degrees in the middle plane with respect to the other. These two GEM-TPCs share the same gas volume, i.e., inside a single vessel. This configuration is called a TWIN configuration. The results presented in this work were measured using the newly integrated VMM3a/SRS readout electronics, an important milestone in improving overall performance and capabilities. In 2024, this detector was tested at the H4 beamline of the SPS at CERN, using muons and pions and with different gas mixtures like, for instance: Ar/CO$_2$ (70/30 \%), He/CO$_2$ (70/30 \%) and He/CO$_2$ (90/10 \%). The helium-based mixtures were used to commission the detector to track low momenta muons required in the PSI muon-induced X-ray emission (MIXE) experiment. The results obtained from these measurements, a brief discussion of the methodology used for the data analysis, and a comparison of the spatial resolution for different gas mixtures will be presented.

physics.ins-det

Towards MPGDs with embedded pixel ASICs

Combining gaseous detectors with a high-granularity pixelated charge readout enables experimental applications which otherwise could not be achieved. This includes high-resolution tracking of low-energetic particles, requiring ultra-low material budget, X-ray polarimetry at low energies ($\lessapprox$ 2 keV) or rare-event searches which profit from event selection based on geometrical parameters. In this article, the idea of embedding a pixel ASIC - specifically the Timepix4 - into a micro-pattern gaseous amplification stage is illustrated. Furthermore, the first results of reading out a triple-GEM detector with the Timepix4 (GEMPix4) are shown, including the first X-ray images taken with a Timepix4 utilising Through Silicon Vias (TSVs). Lastly, a new readout concept is presented, called the 'Silicon Readout Board', extending the use of pixel ASICs to read out gaseous detectors to a wider range of HEP applications.

physics.ins-det

Spatial resolution improvements with finer-pitch GEMs

Gas Electron Multipliers (GEMs) are used in many particle physics experiments, employing their 'standard' configuration with amplification holes of 140 um pitch in a hexagonal pattern. However, the collection of the charge cloud from the primary ionisation electrons from the drift region of the detector into the GEM holes affects the position information from the initial interacting particle. In this paper, the results from studies with a triple-GEM detector with an X-Y-strip readout anode are presented. It is demonstrated that GEMs with a finer hole pitch of here 90 um improve the detector's spatial resolution. Within these studies, also the impact of the front-end electronics on the spatial resolution was investigated, which is briefly discussed in the paper.

physics.ins-det

Characterisation of resistive MPGDs with 2D readout

Micro-Pattern Gaseous Detectors (MPGDs) with resistive anode planes provide intrinsic discharge robustness while maintaining good spatial and time resolutions. Typically read out with 1D strips or pad structures, here the characterisation results of resistive anode plane MPGDs with 2D strip readout are presented. A uRWELL prototype is investigated in view of its use as a reference tracking detector in a future gaseous beam telescope. A MicroMegas prototype with a fine-pitch mesh (730 line-pairs-per-inch) is investigated, both for comparison and to profit from the better field uniformity and thus the ability to operate the detector more stable at high gains. Furthermore, the measurements are another application of the RD51 VMM3a/SRS electronics.

physics.ins-det

The novel XYU-GEM to resolve ambiguities

Removing ambiguities within a single stage becomes crucial when one can not use multiple detectors behind each other to resolve them which naturally is the case for neutral radiation. An example would be RICH detectors. Commonly pixilated readout is choosen for this purpose. However, this causes a remarkable increase in quantity of channels and does not scale up well. Therefore, the XYU-GEM was proposed as a three coordinate strip-readout which is combined with a triple GEM detector. The readout complements a common XY readout with an additional projection which is tilted by 45{\deg}. The overdetermination due to three projections can be used to resovle ambiguities. Following the detector design will be explained, first measurements discussed to understand the response of the detector and a way to change the charge sharing without changing the manufacturing parameters of the readout.

physics.ins-det

Performance of the new RD51 VMM3a/SRS beam telescope---studying MPGDs simultaneously in energy, space and time at high rates

The RD51 collaboration maintains a common infrastructure at CERN for its R & D activities, including two beam telescopes for test beam campaigns. Recently, one of the beam telescopes has been equipped and commissioned with new multi-channel and charge-sensitive front-end electronics based on the ATLAS/BNL VMM3a front-end ASIC and the RD51 Scalable Readout System (SRS). This allows to read out the detectors at high rates (up to the MHz regime) with electronics time resolutions of the order of 1 ns and the ability to handle different detector types and sizes, due to a larger dynamic range compared to the previous front-end electronics based on the APV25 ASIC. Having studied and improved the beam telescope's performance over the course of three test beam campaigns, the results are presented in this paper.

physics.ins-det

Demonstration of Gd-GEM detector design for neutron macromolecular crystallography applications

The European Spallation Source (ESS) in Lund, Sweden will become the world's most powerful thermal neutron source. The Macromolecular Diffractometer (NMX) at the ESS requires three 51.2 x 51.2~cm$^{2}$ detectors with reasonable detection efficiency, sub-mm spatial resolution, a narrow point spread function (PSF) and good time resolution. This work presents measurements with the improved version of the NMX detector prototype consisting of a Triple-GEM detector with natural Gd converter and a low material budget readout. The detector was successfully tested at the neutron reactor of the Budapest Neutron Centre (BNC) and at the D16 instrument at the Institut Laue-Langevin (ILL) in Grenoble. The measurements with Cadmium and Gadolinium masks in Budapest demonstrate that the point spread function of the detector lacks long tails that could impede the measurement of diffraction spot intensities. On the D16 instrument at ILL, diffraction spots from Triose phosphate isomerase w/ 2-phosphoglycolate (PGA) inhibitor were measured both in the D16 Helium-3 detector and the Gd-GEM. The comparison between the two detectors show a similar point spread function in both detectors, and the expected efficiency ratio compared to the Helium-3 detector. Both measurements together thus give good indications that the Gd-GEM detector fits the requirements for the NMX instrument at ESS.

physics.ins-det

Rate-capability of the VMM3a Front End in the RD51 Scalable Readout System

The VMM3a is an Application Specific Integrated Circuit (ASIC), specifically developed for the readout of gaseous detectors. Originally developed within the ATLAS New Small Wheel (NSW) upgrade, it has been successfully integrated into the Scalable Readout System (SRS) of the RD51 collaboration. This allows, to use the VMM3a also in small laboratory set-ups and mid-scale experiments, which make use of Micro-Pattern Gaseous Detectors (MPGDs). As part of the integration of the VMM3a into the SRS, the readout and data transfer scheme was optimised to reach a high rate-capability of the entire readout system and profit from the VMM3a's high single-channel rate-capability of 3.6 Mhits/s. The optimisation focused mainly on the handling of the data output stream of the VMM3a, but also on the development of a trigger-logic between the front-end cards and the DAQ computer. In this article, two firmware implementations of the non-ATLAS continuous readout mode are presented, as well as the implementation of the trigger-logic. Afterwards, a short overview on X-ray imaging results is presented, to illustrate the high rate-capability rom an application point-of-view.

physics.ins-det

Optical Readout Studies of the Thick-COBRA Gaseous Detector

The performance of a Thick-COBRA (THCOBRA) gaseous detector is studied using an optical readout technique. The operation principle of this device is described, highlighting its operation in a gas mixture of Ar/CF4 (80/20%) for visible scintillation light emission. The contributions to the total gain from the holes and the anode strips as a function of the applied bias voltage were visualized. The preservation of spatial information from the initial ionizations was demonstrated by analyzing the light emission from 5.9keV X-rays of an 55Fe source. The observed non-uniformity of the scintillation light from the holes supports the claim of a space localization accuracy better than the pitch of the holes. The acquired images were used to identify weak points and sources of instabilities in view of the development of new optimized structures.

physics.ins-det

Test in a beam of large-area Micromegas chambers for sampling calorimetry

Application of Micromegas for sampling calorimetry puts specific constraints on the design and performance of this gaseous detector. In particular, uniform and linear response, low noise and stability against high ionisation density deposits are prerequisites to achieving good energy resolution. A Micromegas-based hadronic calorimeter was proposed for an application at a future linear collider experiment and three technologically advanced prototypes of 1$\times$1 m$^{2}$ were constructed. Their merits relative to the above-mentioned criteria are discussed on the basis of measurements performed at the CERN SPS test-beam facility.

physics.ins-det