SearcharxivSearch

arXiv subjects

J. Smolik

Publications and source records attributed to J. Smolik.

At least 19 recordsLinked to original sources

Cryogenic characterization of FBK NUV-HD-Cryo 3T SiPM sensors for the DUNE photon detection system

The Deep Underground Neutrino Experiment (DUNE) is a long-baseline neutrino experiment based in the USA and composed of a Near Detector (ND) complex at Fermi National Laboratory (FNAL), and a Far Detector (FD) complex located at the Sanford Underground Research Facility (SURF) $\sim$1300\,km distant. DUNE will study neutrino oscillations looking for unresolved issues of the Standard Model of particle physics (SM) such as CP violation in the leptonic sector, neutrino mass ordering and others, starting from the early 2030s. The FD, with a mass of $\sim$17\,kt, that will exploit both ionization and scintillation signals to detect neutrino interactions with Argon. Scintillating photons in LAr will be detected by the photon detection system (PDS) based on light collectors coupled to Silicon Photomultipliers (SiPMs). During a test campaign, different laboratories of the collaboration performed an investigation of the best SiPM candidates that fulfill the DUNE FD requirements. We identified two models of SiPM, produced by Hamamatsu Photonics K.K. (HPK) and Fondazione Bruno Kessler (FBK), respectively. In this paper, we focus on the FBK selected model showing its main features. We will describe the characterization protocol, the results at both room and cryogenic temperatures and the photon detection efficiency measurements.

physics.ins-det

The \pi^+\pi^- Coulomb interaction study and its use in the data processing

In this work the Coulomb effects (Coulomb correlations) in $\pi^+\pi^-$ pairs produced in p + Ni collisions at 24 GeV/$c$, are studied using experimental $\pi^+\pi^-$ pair distributions in $Q$, the relative momentum in the pair center of mass system (c.m.s), and its projections $Q_L$ (longitudinal component) and $Q_t$ (transverse component) relative to the pair direction in the laboratory system (l.s.). The $Q$, $Q_L$, and $Q_t$ distributions of the {\sl Coulomb pairs} in the c.m.s. have been simulated assuming they are described by the phase space modified by the known point-like Coulomb correlation function $A_C(Q)$, corrected for small effects due to the nonpoint-like pair production and the strong two-pion interaction. The same distributions of {\sl non-Coulomb pairs} have been simulated according to the phase space, but without $A_C(Q)$. It is shown that the number of {\sl Coulomb pairs} in all $Q_t$ intervals, including the small $Q_t$ (small opening angles $\theta$ in the l.s.) is calculated with the theoretical precision better than 2\%. The comparison of the simulated and experimental numbers of {\sl Coulomb pairs} at small $Q_t$ allows us to check and correct the detection efficiency for the pairs with small $\theta$ (0.06 mrad and smaller). It is shown that {\sl Coulomb pairs} can be used as a new physical tool to check and correct the quality of the simulated events. The special property of the {\sl Coulomb pairs} is the possibility of checking and correcting the detection efficiency, especially for the pairs with small opening angles.

hep-ph

Cryogenic front-end amplifier design for large SiPM arrays in the DUNE FD1-HD photon detection system

The photon detection system of the first far detector (FD1-HD) of the DUNE experiment will detect scintillation photons produced by particle interactions in a kiloton-scale liquid Argon time projection chamber. The photon detectors of choice are silicon photomultipliers (SiPM), 6$\times$6 mm$^2$ each, arranged in groups of 48, which present a significantly low impedance to the front-end electronics. This paper details the design of a cryogenic amplifier with exceptionally low white voltage noise of 0.37 nV$\sqrt{Hz}$, based on a silicon-germanium input transistor and a BiCMOS fully differential operational amplifier. It yields excellent single photoelectron resolution even at low overvoltage values. The signal rise time is below 100 ns, and the dynamic range is about 2000 photoelectrons at the typical operating overvoltage. It draws 0.7 mA from a single 3.3 V supply, for a power consumption of 2.4 mW per channel. Simplified models were developed to predict the single photolectron signal shape and the signal to noise ratio, with a good match to measured performance.

physics.ins-det

Investigation of $K^+K^-$ pairs in the effective mass region near $2m_K$

The DIRAC experiment at CERN investigated in the reaction $\rm{p}(24~\rm{GeV}/c) + Ni$ the particle pairs $K^+K^-, π^+ π^-$ and $p \bar{p}$ with relative momentum $Q$ in the pair system less than 100 MeV/c. Because of background influence studies, DIRAC explored three subsamples of $K^+K^-$ pairs, obtained by subtracting -- using time-of-flight (TOF) technique -- background from initial $Q$ distributions with $K^+K^-$ sample fractions more than 70\%, 50\% and 30\%. The corresponding pair distributions in $Q$ and in its longitudinal projection $Q_L$ were analyzed first in a Coulomb model, which takes into account only Coulomb final state interaction (FSI) and assuming point-like pair production. This Coulomb model analysis leads to a $K^+K^-$ yield increase of about four at $Q_L=0.5$ MeV/c compared to 100 MeV/c. In order to study contributions from strong interaction, a second more sophisticated model was applied, considering besides Coulomb FSI also strong FSI via the resonances $f_0(980)$ and $a_0(980)$ and a variable distance $r^*$ between the produced $K$ mesons. This analysis was based on three different parameter sets for the pair production. For the 70\% subsample and with best parameters, $3680\pm 370$ $K^+K^-$ pairs was found to be compared to $3900\pm 410$ $K^+K^-$ extracted by means of the Coulomb model. Knowing the efficiency of the TOF cut for background suppression, the total number of detected $K^+K^-$ pairs was evaluated to be around $40000\pm 10\%$, which agrees with the result from the 30\% subsample. The $K^+K^-$ pair number in the 50\% subsample differs from the two other values by about three standard deviations, confirming -- as discussed in the paper -- that experimental data in this subsample is less reliable.

hep-ex

Energy reconstruction of hadronic showers at the CERN PS and SPS using the Semi-Digital Hadronic Calorimeter

The CALICE Semi-Digital Hadronic CALorimeter (SDHCAL) is the first technological prototype in a family of high-granularity calorimeters developed by the CALICE Collaboration to equip the experiments of future lepton colliders. The SDHCAL is a sampling calorimeter using stainless steel for absorber and Glass Resistive Plate Chambers (GRPC) as a sensitive medium. The GRPC are read out by 1~cm $\times$ 1~cm pickup pads combined to a multi-threshold electronics. The prototype was exposed to hadron beams in both the CERN PS and the SPS beamlines in 2015 allowing the test of the SDHCAL in a large energy range from 3~GeV to 80~GeV. After introducing the method used to select the hadrons of our data and reject the muon and electron contamination, we present the energy reconstruction approach that we apply to the data collected from both beamlines and we discuss the response linearity and the energy resolution of the SDHCAL. The results obtained in the two beamlines confirm the excellent SDHCAL performance observed with the data collected with the same prototype in the SPS beamline in 2012. They also show the stability of the SDHCAL in different beam conditions and different time periods.

hep-ex

Particle Identification Using Boosted Decision Trees in the Semi-Digital Hadronic Calorimeter Prototype

The CALICE Semi-Digital Hadronic CALorimeter (SDHCAL) prototype using Glass Resistive Plate Chambers as a sensitive medium is the first technological prototype of a family of high-granularity calorimeters developed by the CALICE collaboration to equip the experiments of future leptonic colliders. It was exposed to beams of hadrons, electrons and muons several times in the CERN PS and SPS beamlines between 2012 and 2018. We present here a new method of particle identification within the SDHCAL using the Boosted Decision Trees (BDT) method applied to the data collected in 2015. The performance of the method is tested first with Geant4-based simulated events and then on the data collected by the SDHCAL in the energy range between 10 and 80~GeV with 10~GeV energy steps. The BDT method is then used to reject the electrons and muons that contaminate the SPS hadron beams.

physics.ins-det

Characterisation of different stages of hadronic showers using the CALICE Si-W ECAL physics prototype

A detailed investigation of hadronic interactions is performed using $π^-$-mesons with energies in the range 2--10 GeV incident on a high granularity silicon-tungsten electromagnetic calorimeter. The data were recorded at FNAL in 2008. The region in which the $π^-$-mesons interact with the detector material and the produced secondary particles are characterised using a novel track-finding algorithm that reconstructs tracks within hadronic showers in a calorimeter in the absence of a magnetic field. The principle of carrying out detector monitoring and calibration using secondary tracks is also demonstrated.

physics.ins-det

Analysis of Testbeam Data of the Highly Granular RPC-Steel CALICE Digital Hadron Calorimeter and Validation of Geant4 Monte Carlo Models

We present a study of the response of the highly granular Digital Hadronic Calorimeter with steel absorbers, the Fe-DHCAL, to positrons, muons, and pions with momenta ranging from 2 to 60 GeV/c. Developed in the context of the CALICE collaboration, this hadron calorimeter utilises Resistive Plate Chambers as active media, interspersed with steel absorber plates. With a transverse granularity of $1\,\times\,1\,$cm$^{2}$ and a longitudinal segmentation of 38 layers, the calorimeter counted 350,208 readout channels, each read out with single-bit resolution (digital readout). The data were recorded in the Fermilab test beam in 2010-11. The analysis includes measurements of the calorimeter response and the energy resolution to positrons and muons, as well as detailed studies of various shower shape quantities. The results are compared to simulations based on Geant4, which utilise different electromagnetic and hadronic physics lists.

physics.ins-det

First measurement of a long-lived $π^+ π^-$ atom lifetime

The adapted DIRAC experiment at the CERN PS accelerator observed for the first time long-lived hydrogen-like $π^+π^-$ atoms, produced by protons hitting a beryllium target. A part of these atoms crossed the gap of 96~mm and got broken up in the 2.1~\textmu{}m thick platinum foil. Analysing the observed number of atomic pairs, $n_A^L= \left.436^{+157}_{-61}\right|_\mathrm{tot}$, the lifetime of the 2$p$ state is found to be ${τ_{2p}=(\left.0.45^{+1.08}_{-0.30}\right|_\mathrm{tot}) \cdot10^{-11}}$s, not contradicting the corresponding QED $2p$ state lifetime ${τ_{2p}^\mathrm{QED}=1.17 \cdot 10^{-11}}$s. This lifetime value is three orders of magnitude larger than our previously measured value of the $π^+π^-$ atom ground state lifetime $τ=(\left.3.15^{+0.28}_{-0.26}\right|_\mathrm{tot})\cdot 10^{-15}$s. Further studies of long-lived $π^+π^-$ atoms will allow to measure energy differences between $p$ and $s$ atomic states and so to determine $ππ$ scattering lengths with the aim to check QCD predictions.

hep-ex

Hadronic Energy Resolution of a Combined High Granularity Scintillator Calorimeter System

This paper presents results obtained with the combined CALICE Scintillator Electromagnetic Calorimeter, Analogue Hadronic Calorimeter and Tail Catcher & Muon Tracker, three high granularity scintillator-SiPM calorimeter prototypes. The response of the system to pions with momenta between 4 GeV/c and 32 GeV/c is analysed, including the energy response, resolution, and longitudinal shower profiles. The results of a software compensation technique based on weighting according to hit energy are compared to those of a standard linear energy reconstruction. The results are compared to predictions of the GEANT4 physics lists QGSP_BERT_HP and FTFP_BERT_HP.

physics.ins-det

Construction and Response of a Highly Granular Scintillator-based Electromagnetic Calorimeter

A highly granular electromagnetic calorimeter with scintillator strip readout is being developed for future lepton collider experiments. A prototype of 21.5 $X_0$ depth and $180 \times 180 $mm$^2$ transverse dimensions was constructed, consisting of 2160 individually read out $10 \times 45 \times 3$ mm$^3$ scintillator strips. This prototype was tested using electrons of 2--32 GeV at the Fermilab Test Beam Facility in 2009. Deviations from linear energy response were less than 1.1\%, and the intrinsic energy resolution was determined to be $(12.5 \pm 0.1 (\mathrm{stat.}) \pm0.4 (\mathrm{syst.}))\%/\sqrt{E[\mathrm{GeV}]}\oplus (1.2 \pm 0.1(\mathrm{stat.})^{+0.6}_{-0.7}(\mathrm{syst.}))\%$, where the uncertainties correspond to statistical and systematic sources, respectively.

physics.ins-det

Measurement of the $πK$ atom lifetime and the $πK$ scattering length

After having announced the statistically significant observation (5.6~$σ$) of the new exotic $πK$ atom, the DIRAC experiment at the CERN proton synchrotron presents the measurement of the corresponding atom lifetime, based on the full $πK$ data sample: $τ= (5.5^{+5.0}_{-2.8}) \cdot 10^{-15}s$. By means of a precise relation ($<1\%$) between atom lifetime and scattering length, the following value for the S-wave isospin-odd $πK$ scattering length $a_0^{-}~=~\frac{1}{3}(a_{1/2}-a_{3/2})$ has been derived: $\left|a_0^-\right| = (0.072^{+0.031}_{-0.020}) M_π^{-1}$.

hep-ex

DHCAL with Minimal Absorber: Measurements with Positrons

In special tests, the active layers of the CALICE Digital Hadron Calorimeter prototype, the DHCAL, were exposed to low energy particle beams, without being interleaved by absorber plates. The thickness of each layer corresponded approximately to 0.29 radiation lengths or 0.034 nuclear interaction lengths, defined mostly by the copper and steel skins of the detector cassettes. This paper reports on measurements performed with this device in the Fermilab test beam with positrons in the energy range of 1 to 10 GeV. The measurements are compared to simulations based on GEANT4 and a standalone program to emulate the detailed response of the active elements.

physics.ins-det

Opticle fibre calibration system and adaptive power supply

We summarize the recent activity of our group in the calibration, monitoring and gain stabilization of photodetectors, primarily silicon photomultipliers, in calorimeters using scintillator as active medium. The task originally solved for the CALICE analog hadron calorimeter founds application in other experiments.

physics.ins-det

First $πK$ atom lifetime and $πK$ scattering length measurements

The results of a search for hydrogen-like atoms consisting of $π^{\mp}K^{\pm}$ mesons are presented. Evidence for $πK$ atom production by 24 GeV/c protons from CERN PS interacting with a nickel target has been seen in terms of characteristic $πK$ pairs from their breakup in the same target ($178 \pm 49$) and from Coulomb final state interaction ($653 \pm 42$). Using these results the analysis yields a first value for the $πK$ atom lifetime of $τ=(2.5_{-1.8}^{+3.0})$ fs and a first model-independent measurement of the S-wave isospin-odd $πK$ scattering length $\left|a_0^-\right|=\frac{1}{3}\left|a_{1/2}-a_{3/2}\right|= \left(0.11_{-0.04}^{+0.09} \right)M_π^{-1}$ ($a_I$ for isospin $I$).

nucl-ex

Determination of $ππ$ scattering lengths from measurement of $π^+π^-$ atom lifetime

The DIRAC experiment at CERN has achieved a sizeable production of $π^+π^-$ atoms and has significantly improved the precision on its lifetime determination. From a sample of 21227 atomic pairs, a 4% measurement of the S-wave $ππ$ scattering length difference $|a_0-a_2| = (.0.2533^{+0.0080}_{-0.0078}|_\mathrm{stat}.{}^{+0.0078}_{-0.0073}|_\mathrm{syst})M_{π^+}^{-1}$ has been attained, providing an important test of Chiral Perturbation Theory.

hep-ex

Calibration prototype for the EUDET HCAL

The electronics producing a few nanoseconds long LED pulses tuneable in the amplitude and the optical system distributing the LED light to scintillators by a single optical fibre are described. The properties of the LED pulses are controlled by a computer connected via a CANbus to the controller on the board. We produced a prototype with 6 LED pulse drivers placed on a 4-layer PCB with dimension 250 x 147 mm2. The pulse width is constant and 3 ns long. Its amplitude can be tuned from zero to 1.2 A. The pulse frequency can be set in the range up to 100 kHz. The LED light is distributed by a 1 mm diameter optical fibre. On the length of 2 m the fibre has every 30 mm a notch which flashes light with homogeneity of \pm20%. The system is foreseen for calibration of silicon photomultipliers embedded in scintillation tiles.

physics.ins-det

Evidence for $πK$-atoms with DIRAC

We present evidence for the first observation of electromagnetically bound $π^\pm K^\mp$-pairs ($πK$-atoms) with the DIRAC experiment at the CERN-PS. The $πK$-atoms are produced by the 24 GeV/c proton beam in a thin Pt-target and the $π^\pm$ and $K^\mp$-mesons from the atom dissociation are analyzed in a two-arm magnetic spectrometer. The observed enhancement at low relative momentum corresponds to the production of 173 $\pm$ 54 $πK$-atoms. The mean life of $πK$-atoms is related to the s-wave $πK$-scattering lengths, the measurement of which is the goal of the experiment. From these first data we derive a lower limit for the mean life of 0.8 fs at 90% confidence level.

hep-ex