Searcharxiv⌕ Search

arXiv subjects

J. Sylwester

Publications and source records attributed to J. Sylwester.

23 records · Page 2Linked to original sources

A solar spectroscopic absolute abundance of argon from RESIK

Observations of He-like and H-like Ar (Ar XVII and Ar XVIII) lines at 3.949 Angstroms and 3.733 Angstroms respectively with the RESIK X-ray spectrometer on the CORONAS-F spacecraft, together with temperatures and emission measures from the two channels of GOES, have been analyzed to obtain the abundance of Ar in flare plasmas in the solar corona. The line fluxes per unit emission measure show a temperature dependence like that predicted from theory, and lead to spectroscopically determined values for the absolute Ar abundance, A(Ar) = 6.44 pm 0.07 (Ar XVII) and 6.49 pm 0.16 (Ar XVIII) which are in agreement to within uncertainties. The weighted mean is 6.45 pm 0.06, which is between two recent compilations of the solar Ar abundance and suggest that the photospheric and coronal abundances of Ar are very similar.

astro-ph.SR↗

Soft X-ray coronal spectra at low activity levels observed by RESIK

The quiet-Sun X-ray emission is important for deducing coronal heating mechanisms, but it has not been studied in detail since the Orbiting Solar Observatory (OSO) spacecraft era. Bragg crystal spectrometer X-ray observations have generally concentrated on flares and active regions. The high sensitivity of the RESIK (REntgenovsky Spectrometer s Izognutymi Kristalami) instrument on the CORONAS-F solar mission has enabled the X-ray emission from the quiet corona to be studied in a systematic way for the first time. Our aim is to deduce the physical conditions of the non-flaring corona from RESIK line intensities in several spectral ranges using both isothermal and multithermal assumptions. We selected and analyzed spectra in 312 quiet-Sun intervals in January and February 2003, sorting them into 5 groups according to activity level. For each group, the fluxes in selected spectral bands have been used to calculate values parameters for the best-fit that lead to a intensities characteristic of each group. We used both isothermal and multitemperature assumptions, the latter described by differential emission measure (DEM) distributions. RESIK spectra cover the wavelength range (3.3-6.1 A). This includes emission lines of highly ionized Si, S, Cl, Ar, and K, which are suitable for evaluating temperature and emission measure, were used. The RESIK spectra during these intervals of very low solar activity for the first time provide information on the temperature structure of the quiet corona. Although most of the emission seems to arise from plasma with a temperature between 2MK and 3MK, there is also evidence of a hotter plasma (T approx. 10MK) with an emission measure 3 orders smaller than the cooler component. Neither coronal nor photospheric element abundances appear to describe the observed spectra satisfactorily.

astro-ph.SR↗

The solar X-ray continuum measured by RESIK

The solar X-ray continuum emission at five wavelengths between 3.495 Angstroms and 4.220 Angstroms for 19 flares in a seven-month period in 2002--2003 was observed by the RESIK crystal spectrometer on CORONAS-F. In this wavelength region, free--free and free--bound emissions have comparable fluxes. With a pulse-height analyzer having settings close to optimal, the fluorescence background was removed so that RESIK measured true solar continuum in these bands with an uncertainty in the absolute calibration of plus or minus 20 per cent. With an isothermal assumption, and temperature and emission measure derived from the ratio of the two GOES channels, the observed continuum emission normalized to an emission measure of 10^48 cm^-3 was compared with theoretical continua using the CHIANTI atomic code. The accuracy of the RESIK measurements allows photospheric and coronal abundance sets, important for the free--bound continuum, to be discriminated. It is found that there is agreement to about 25 per cent of the measured continua with those calculated from CHIANTI assuming coronal abundances in which Mg, Si, Fe abundances are four times photospheric.

astro-ph.SR↗

Highly Ionized Potassium Lines in Solar X-ray Spectra and the Abundance of Potassium

The abundance of potassium is derived from X-ray lines observed during flares by the RESIK instrument on the solar mission CORONAS-F between 3.53 A and 3.57 A. The lines include those emitted by He-like K and Li-like K dielectronic satellites, which have been synthesized using the CHIANTI atomic code and newly calculated atomic data. There is good agreement of observed and synthesized spectra, and the theoretical behavior of the spectra with varying temperature estimated from the ratio of the two GOES channels is correctly predicted. The observed fluxes of the He-like K resonance line per unit emission measure gives log A(K) = 5.86 (on a scale log A(H) = 12), with a total range of a factor 2.9. This is higher than photospheric abundance estimates by a factor 5.5, a slightly greater enhancement than for other elements with first ionization potential (FIP) less than about 10 eV. There is, then, the possibility that enrichment of low-FIP elements in coronal plasmas depends weakly on the value of the FIP which for K is extremely low (4.34 eV). Our work also suggests that fractionation of elements to form the FIP effect occurs in the low chromosphere rather than higher up, as in some models.

astro-ph.SR↗

RESIK observations of He-like Ar X-ray line emission in solar flares

The Ar XVII X-ray line group principally due to transitions 1s2 - 1s2l (l=s, p) near 4 Anstroms was observed in numerous flares by the RESIK bent crystal spectrometer aboard CORONAS-F between 2001 and 2003. The three line features include the Ar XVII w (resonance line), a blend of x and y (intercombination lines), and z (forbidden line), all of which are blended with Ar XVI dielectronic satellites. The ratio G, equal to [I(x+y) + I(z)]/I(w), varies with electron temperature Te mostly because of unresolved dielectronic satellites. With temperatures estimated from GOES X-ray emission, the observed G ratios agree fairly well with those calculated from CHIANTI and other data. With a two-component emission measure, better agreement is achieved. Some S XV and S XVI lines blend with the Ar lines, the effect of which occurs at temperatures greater than 8MK, allowing the S/Ar abundance ratio to be determined. This is found to agree with coronal values. A nonthermal contribution is indicated for some spectra in the repeating-pulse flare of 2003 February 6.

astro-ph↗