Comparative Evaluation of Transition Mechanisms for Adaptive Droop Gains in Parallel Grid-Forming Inverters

Uncertainty in standalone microgrid operation usually originates from mismatches between power references and forecasts. These deviations are compensated by grid-forming controlled units, which distribute the required power contribution based on their droop gains. To introduce an additional degree of flexibility, it is possible to treat droop gains as decision variables to redistribute active-power contributions according to system-level objectives. However, directly applying updated droop gain references from a supervisory layer to the primary controllers can introduce power and frequency transients. This paper investigates transition mechanisms for applying scheduled active-power droop gain changes during operation. Hard switching, rate-limited transition, first-order IIR low-pass filtering, and cubic as well as quintic S-curve transitions are compared experimentally on two parallel 15 kW grid-forming inverter units. The results show that shaping the droop gain trajectory significantly reduces transient deviations compared to hard switching. In the considered case study, the S-curve transitions provide the strongest transient mitigation, reducing the active-power overshoot from 632.7 W to approximately 115 W and limiting the frequency overshoot to about 0.003 Hz.

eess.SY

Experimental Characterisation of Distributed Reactive Power Sharing under Communication-Induced Stress in Parallel Grid-Forming Inverters

Synchronisation of parallel grid-forming inverters is crucial for stable operation of future power systems. This includes accurate and robust reactive power sharing under realistic operating conditions such as impedance mismatch and communication constraints. In this work, reactive power sharing by virtue of a distributed control law is investigated under line impedance mismatch. Furthermore, robustness and transient behaviour of the proposed approach are experimentally evaluated under communication-induced stressors including a fixed 3% packet loss and communication delays ranging from 50 ms to 100 ms, artificially introduced through a software-defined overlay. The study is conducted in a low-voltage laboratory-scale microgrid comprising two parallel grid-forming inverters, an AC load, and a grid-following battery system acting as a reactive power injector. The results show reactive power sharing convergence up to 90 ms communication delay, with a stability boundary between 90 ms and 100 ms, which decreases with increasing integral gain.

eess.SY