The Hot and Energetic Universe: The Wide Field Imager (WFI) for Athena+

The Wide Field Imager (WFI) is one of the two scientific instruments proposed for the Athena+ X-ray observatory. It will provide imaging in the 0.1-15 keV band over a wide field, simultaneously with spectrally and time-resolved photon counting. The instrument is designed to make optimal use of the grasp (collecting area times solid angle product) provided by the optical design of the Athena+ mirror system (Willingale et al. 2013), by combining a sensitive approx. 40' diameter field of view (baseline; 50' goal) DEPFET detector with a pixel size properly sampling the angular resolution of 5 arc sec on-axis (half energy width).This synthesis makes the WFI a very powerful survey instrument, significantly surpassing currently existing capabilities (Nandra et al. 2013; Aird et al. 2013). In addition, the WFI will provide unprecedented simultaneous high-time resolution and high count rate capabilities for the observation of bright sources with low pile-up and high efficiency. In this paper, we summarize the instrument design, the status of the technology development, and the baseline performance.

astro-ph.IM

New Results on DEPFET Pixel Detectors for Radiation Imaging and High Energy Particle Detection

DEPFET pixel detectors are unique devices in terms of energy and spatial resolution because very low noise (ENC = 2.2e at room temperature) operation can be obtained by implementing the amplifying transistor in the pixel cell itself. Full DEPFET pixel matrices have been built and operated for autoradiographical imaging with imaging resolutions of 4.3 +- 0.8 um at 22 keV. For applications in low energy X-ray astronomy the high energy resolution of DEPFET detectors is attractive. For particle physics, DEPFET pixels are interesting as low material detectors with high spatial resolution. For a Linear Collider detector the readout must be very fast. New readout chips have been designed and produced for the development of a DEPFET module for a pixel detector at the proposed TESLA collider (520x4000 pixels) with 50 MHz line rate and 25 kHz frame rate. The circuitry contains current memory cells and current hit scanners for fast pedestal subtraction and sparsified readout. The imaging performance of DEPFET devices as well as present achievements towards a DEPFET vertex detector for a Linear Collider are presented.

physics.ins-det

A modular PC based silicon microstrip beam telescope with high speed data acquisition

A PC based high speed silicon microstrip beam telescope consisting of several independent modules is presented. Every module contains an AC-coupled double sided silicon microstrip sensor and a complete set of analog and digital signal processing electronics. A digital bus connects the modules with the DAQ PC. A trigger logic unit coordinates the operation of all modules of the telescope. The system architecture allows easy integration of any kind of device under test into the data acquisition chain. Signal digitization, pedestal correction, hit detection and zero suppression are done by hardware inside the modules, so that the amount of data per event is reduced by a factor of 80 compared to conventional readout systems. In combination with a two level data acquisition scheme, this allows event rates up to 7.6 kHz. This is a factor of 40 faster than conventional VME based beam telescopes while comparable analog performance is maintained achieving signal to noise ratios of up to 70:1. The telescope has been tested in the SPS testbeam at CERN. It has been adopted as the reference instrument for testbeam studies for the ATLAS pixel detector development.

physics.ins-det