SearcharxivSearch

arXiv subjects

J. Ullom

Publications and source records attributed to J. Ullom.

18 recordsLinked to original sources

The SPT-3G+ receiver design

We present the thermo-mechanical design of the cryostat and camera optics for SPT-3G+, a new receiver being developed for the South Pole Telescope (SPT). The receiver consists of 14 detector arrays of 90/150 GHz dichroic polarization-sensitive pixels, totaling 24,080 transition-edge sensor detectors. Each detector array lies at the end of an optics tube, each approximately 240 mm in diameter and 772 mm in length, which are arranged in a hexagonal close-packed configuration to achieve a 4 degree diameter field of view. Each optics tube contains four anti-reflection coated lenses fabricated from different materials (alumina, silicon, and nylon) that are designed to also provide infrared filtering that reduces the radiative loading on the cryogenic stages. The optics and detectors are cooled by a combination of a pulse tube cooler for the 40 K and 4 K stages, and a dilution refrigerator for the 1 K and 100 mK stages. Thermal modeling predicts the heat load to be less than 26 W and 1 W for the 40 K and 4 K stages, respectively. The 1,550 kg cryostat has a 1.1 meter diameter at the vacuum window, which is located near the telescope Gregorian focus, and 1.75 meters in height and length. Fabrication of the cryostat will begin in 2026, with installation on the SPT scheduled for the 2028-29 austral summer, ahead of the 2029 winter observing season.

astro-ph.IM

SPT-3G+: A Cosmic Microwave Background Experiment for the South Pole Telescope

SPT-3G+ is the next survey receiver planned to be installed in early 2029 on the 10-meter South Pole Telescope (SPT). This new receiver will feature 6,020 polarization-sensitive dichroic pixels with transition-edge sensors observing in frequency bands centered at 90 GHz and 150 GHz. The 24,080 detectors in the SPT-3G+ receiver will be cooled to 100 mK by a dilution refrigerator and read out using microwave SQUID multiplexing. The optical design of the receiver enables a 4 degree diameter field of view, which is broken up into 14 individual optics tubes each containing cryogenic alumina, silicon, and nylon lenses. These technology choices will allow the SPT-3G+ receiver to improve on the mapping speed of the currently operating SPT-3G receiver by nearly an order of magnitude. Once deployed, the SPT-3G+ receiver will observe for 6-years an area overlapping with the BICEP survey to achieve a combined (90 GHz and 150 GHz) CMB map depth of 0.5 uK-arcmin. Data from these observations will be used to create unprecedentedly deep CMB lensing maps, discover new galaxy clusters, and detect astrophysical transients. The lensing map produced by SPT-3G+ will be used to remove or "delens" foreground B modes, where large-scale structure gravitationally lenses the CMB and converts E modes into B-mode polarization, with the goal of revealing inflationary B modes. Together with data from the BICEP Array as part of the South Pole Observatory, SPT-3G+ data will be used to constrain the tensor-to-scalar ratio $r$ with a goal of achieving a measurement of $\sigma(r) = 0.001$

astro-ph.CO

Demonstration of a 1820 channel multiplexer for transition-edge sensor bolometers

The scalability of most transition-edge sensor arrays is limited by the multiplexing technology which combines their signals over a reduced number of wires and amplifiers. In this Letter, we present and demonstrate a multiplexer design optimized for transition-edge sensor bolometers with 1820 sensors per readout unit, a factor of two more than the previous state-of-the-art. The design is optimized for cosmic microwave background imaging applications, and it builds on previous microwave superconducting quantum interference device multiplexers by doubling the available readout bandwidth to the full 4-8 GHz octave. Evaluating the key performance metrics of yield, sensitivity, and crosstalk through laboratory testing, we find an end-to-end operable detector yield of 78%, a typical nearest-neighbor crosstalk amplitude of ~0.4%, and a median white noise level of 83 pA/rtHz due to the multiplexer, corresponding to an estimated contribution of 4% to the total system noise for a ground-based cosmic microwave background telescope. Additionally, we identify a possible path toward reducing resonator loss for future designs with reduced noise. We expect these developments to alleviate the system complexity, cryogenic requirements, and cost of future large arrays of low temperature detectors.

physics.ins-det

Kinetic Inductance Traveling Wave Parametric Amplifiers Near the Quantum Limit: Methodology and Characterization

We present a detailed simulation and design framework for realizing traveling wave parametric amplifiers (TWPAs) using the nonlinear kinetic inductance of disordered superconductors -- in our case niobium-titanium-nitride (NbTiN). These kinetic inductance TWPAs (KITs) operate via three-wave mixing (3WM) to achieve high broadband gain and near-quantum-limited (nQL) noise. Representative fabricated devices -- realized using an inverted microstrip (IMS), dispersion-engineered, artificial transmission line -- demonstrate power gains above 25 dB, bandwidths beyond 3 GHz, and achieve ultimate system noise levels of 1.1 quanta even when operated with no magnetic shielding. These performance metrics are competitive with state-of-the-art Josephson-junction-based TWPAs but involve simpler fabrication and able to providing three orders of magnitude higher dynamic range ($IIP_1 = -68$ dBm, $IIP_3 = -55$ dBm), and high magnetic field resilience -- making KITs an attractive technology for highly multiplexed readout of quantum information and superconducting detector systems.

quant-ph

Noise limits for dc SQUID readout of high-$Q$ resonators below 300 MHz

We present the limits on noise for the readout of cryogenic high-$Q$ resonators using dc Superconducting Quantum Interference Devices (SQUIDs) below 300 MHz. This analysis uses realized first-stage SQUIDs (previously published), whose performance is well described by Tesche-Clarke (TC) theory, coupled directly to the resonators. We also present data from a prototype second-stage dc SQUID array designed to couple to this first-stage SQUID as a follow-on amplifier with high system bandwidth. This analysis is the first full consideration of dc SQUID noise performance referred to a high-$Q$ resonator over this frequency range, and is presented relative to the standard quantum limit. We include imprecision, backaction, and backaction-imprecision noise correlations from TC theory, the noise contributed by the second-stage SQUIDs, wiring, and preamplifiers, and optimizations for both on-resonance measurements and off-resonance scan sensitivity. This architecture has modern relevance due to the increased interest in axion searches and the requirements of the DMRadio-m$^3$ axion search, which will use dc SQUIDs in this frequency range.

quant-ph

In-Flight Performance of Spider's 280 GHz Receivers

SPIDER is a balloon-borne instrument designed to map the cosmic microwave background at degree-angular scales in the presence of Galactic foregrounds. SPIDER has mapped a large sky area in the Southern Hemisphere using more than 2000 transition-edge sensors (TESs) during two NASA Long Duration Balloon flights above the Antarctic continent. During its first flight in January 2015, SPIDER observed in the 95 GHz and 150 GHz frequency bands, setting constraints on the B-mode signature of primordial gravitational waves. Its second flight in the 2022-2023 season added new receivers at 280 GHz, each using an array of TESs coupled to the sky through feedhorns formed from stacks of silicon wafers. These receivers are optimized to produce deep maps of polarized Galactic dust emission over a large sky area, providing a unique data set with lasting value to the field. We describe the instrument's performance during SPIDER's second flight, focusing on the performance of the 280 GHz receivers. We include details on the flight, in-band optical loading at float, and an early analysis of detector noise.

astro-ph.IM

Decay Energy Spectrometry for Improved Nuclear Material Analysis at the IAEA NML

Decay energy spectrometry (DES) is a novel radiometric technique for high-precision analysis of nuclear materials. DES employs the unique thermal detection physics of cryogenic microcalorimeters with ultra-high energy resolution and 100$\%$ detection efficiency to accomplish high precision decay energy measurements. Low-activity nuclear samples of 1 Bq or less, and without chemical separation, are used to provide elemental and isotopic compositions in a single measurement. Isotopic ratio precisions of 1 ppm - 1,000 ppm (isotope dependent), which is close to that of the mass spectrometry, have been demonstrated in 12-hour DES measurements of ~5 Bq samples of certified reference materials of uranium (U) and plutonium (Pu). DES has very different systematic biases and uncertainties, as well as different sensitivities to nuclides, compared to mass-spectrometry techniques. Therefore, the accuracy and confidence of nuclear material assays can be improved by combining this new technique with existing mass-spectrometry techniques. Commercial-level DES techniques and equipment are being developed for the implementation of DES at the Nuclear Material Laboratory (NML) of International Atomic Energy Agency (IAEA) to provide complementary measurements to the existing technologies. The paper describes details of DES measurement methods, as well as DES precision and accuracy to U and Pu standard sources to discuss its capability in analysis of nuclear safeguards samples.

physics.ins-det

Kinetic inductance traveling wave amplifier designs for practical microwave readout applications

A Kinetic Inductance Traveling Wave amplifier (KIT) utilizes the nonlinear kinetic inductance of superconducting films, particularly Niobium Titanium Nitride (NbTiN), for parametric amplification. These amplifiers achieve remarkable performance in terms of gain, bandwidth, compression power, and frequently approach the quantum limit for noise. However, most KIT demonstrations have been isolated from practical device readout systems. Using a KIT as the first amplifier in the readout chain of an unoptimized microwave SQUID multiplexer coupled to a transition-edge sensor microcalorimeter we see an initial improvement in the flux noise. One challenge in KIT integration is the considerable microwave pump power required to drive the non-linearity. To address this, we have initiated efforts to reduce the pump power by using thinner NbTiN films and an inverted microstrip transmission line design. In this article, we present the new transmission line design, fabrication procedure, and initial device characterization -- including gain and added noise. These devices exhibit over 10 dB of gain with a 3 dB bandwidth of approximately 5.5-7.25 GHz, a maximum practical gain of 12 dB and typical gain ripple under 4 dB peak-to-peak. We observe an appreciable impedance mismatch in the NbTiN transmission line, which is likely the source of the majority of the gain ripple. Finally we perform an initial noise characterization and demonstrate system-added noise of three quanta or less over nearly the entire 3 dB bandwidth.

quant-ph

Design and pre-flight performance of SPIDER 280 GHz receivers

In this work we describe upgrades to the Spider balloon-borne telescope in preparation for its second flight, currently planned for December 2021. The Spider instrument is optimized to search for a primordial B-mode polarization signature in the cosmic microwave background at degree angular scales. During its first flight in 2015, Spider mapped ~10% of the sky at 95 and 150 GHz. The payload for the second Antarctic flight will incorporate three new 280 GHz receivers alongside three refurbished 95- and 150 GHz receivers from Spider's first flight. In this work we discuss the design and characterization of these new receivers, which employ over 1500 feedhorn-coupled transition-edge sensors. We describe pre-flight laboratory measurements of detector properties, and the optical performance of completed receivers. These receivers will map a wide area of the sky at 280 GHz, providing new information on polarized Galactic dust emission that will help to separate it from the cosmological signal.

astro-ph.IM

Status of the HOLMES Experiment to Directly Measure the Neutrino Mass

The assessment of neutrino absolute mass scale is still a crucial challenge in today particle physics and cosmology. Beta or electron capture spectrum end-point study is currently the only experimental method which can provide a model independent measurement of the absolute scale of neutrino mass. HOLMES is an experiment funded by the European Research Council to directly measure the neutrino mass. HOLMES will perform a calorimetric measurement of the energy released in the electron capture decay of the artificial isotope $^{163}$Ho. In a calorimetric measurement the energy released in the decay process is entirely contained into the detector, except for the fraction taken away by the neutrino. This approach eliminates both the issues related to the use of an external source and the systematic uncertainties arising from decays on excited final states. The most suitable detectors for this type of measurement are low temperature thermal detectors, where all the energy released into an absorber is converted into a temperature increase that can be measured by a sensitive thermometer directly coupled with the absorber. This measurement was originally proposed in 1982 by A. De Rujula and M. Lusignoli, but only in the last decade the technological progress in detectors development has allowed to design a sensitive experiment. HOLMES plans to deploy a large array of low temperature microcalorimeters with implanted $^{163}$Ho nuclei. In this contribution we outline the HOLMES project with its physics reach and technical challenges, along with its status and perspectives.

physics.ins-det

SLAC Microresonator Radio Frequency (SMuRF) Electronics for Read Out of Frequency-Division-Multiplexed Cryogenic Sensors

Large arrays of cryogenic sensors for various imaging applications ranging across x-ray, gamma-ray, Cosmic Microwave Background (CMB), mm/sub-mm, as well as particle detection increasingly rely on superconducting microresonators for high multiplexing factors. These microresonators take the form of microwave SQUIDs that couple to Transition-Edge Sensors (TES) or Microwave Kinetic Inductance Detectors (MKIDs). In principle, such arrays can be read out with vastly scalable software-defined radio using suitable FPGAs, ADCs and DACs. In this work, we share plans and show initial results for SLAC Microresonator Radio Frequency (SMuRF) electronics, a next-generation control and readout system for superconducting microresonators. SMuRF electronics are unique in their implementation of specialized algorithms for closed-loop tone tracking, which consists of fast feedback and feedforward to each resonator's excitation parameters based on transmission measurements. Closed-loop tone tracking enables improved system linearity, a significant increase in sensor count per readout line, and the possibility of overcoupled resonator designs for enhanced dynamic range. Low-bandwidth prototype electronics were used to demonstrate closed-loop tone tracking on twelve 300-kHz-wide microwave SQUID resonators, spaced at $\sim$6 MHz with center frequencies $\sim$5-6 GHz. We achieve multi-kHz tracking bandwidth and demonstrate that the noise floor of the electronics is subdominant to the noise intrinsic in the multiplexer.

astro-ph.IM

Measurement of optical constants of TiN and TiN/Ti/TiN multilayer films for microwave kinetic inductance photon-number-resolving detectors

We deposit thin titanium-nitride (TiN) and TiN/Ti/TiN multilayer films on sapphire substrates and measure the reflectance and transmittance in the wavelength range from 400 nm to 2000 nm using a spectrophotometer. The optical constants (complex refractive indices), including the refractive index n and the extinction coefficient k, have been derived. With the extracted refractive indices, we propose an optical stack structure using low-loss amorphous Si (a-Si) anti-reflective coating and a backside aluminum (Al) reflecting mirror, which can in theory achieve 100% photon absorption at 1550 nm. The proposed optical design shows great promise in enhancing the optical efficiency of TiN-based microwave kinetic inductance photon-number-resolving detectors.

physics.optics

280 GHz Focal Plane Unit Design and Characterization for the SPIDER-2 Suborbital Polarimeter

We describe the construction and characterization of the 280 GHz bolometric focal plane units (FPUs) to be deployed on the second flight of the balloon-borne SPIDER instrument. These FPUs are vital to SPIDER's primary science goal of detecting or placing an upper limit on the amplitude of the primordial gravitational wave signature in the cosmic microwave background (CMB) by constraining the B-mode contamination in the CMB from Galactic dust emission. Each 280 GHz focal plane contains a 16 x 16 grid of corrugated silicon feedhorns coupled to an array of aluminum-manganese transition-edge sensor (TES) bolometers fabricated on 150 mm diameter substrates. In total, the three 280 GHz FPUs contain 1,530 polarization sensitive bolometers (765 spatial pixels) optimized for the low loading environment in flight and read out by time-division SQUID multiplexing. In this paper we describe the mechanical, thermal, and magnetic shielding architecture of the focal planes and present cryogenic measurements which characterize yield and the uniformity of several bolometer parameters. The assembled FPUs have high yields, with one array as high as 95% including defects from wiring and readout. We demonstrate high uniformity in device parameters, finding the median saturation power for each TES array to be ~3 pW at 300 mK with a less than 6% variation across each array at one standard deviation. These focal planes will be deployed alongside the 95 and 150 GHz telescopes in the SPIDER-2 instrument, slated to fly from McMurdo Station in Antarctica in December 2018.

astro-ph.IM

Counting Near Infrared Photons with Microwave Kinetic Inductance Detectors

We demonstrate photon counting at 1550 nm wavelength using microwave kinetic inductance detectors (MKIDs) made from TiN/Ti/TiN trilayer films with superconducting transition temperature Tc ~ 1.4 K. The detectors have a lumped-element design with a large interdigitated capacitor (IDC) covered by aluminum and inductive photon absorbers whose volume ranges from 0.4 um^3 to 20 um^3. We find that the energy resolution improves as the absorber volume is reduced. We have achieved an energy resolution of 0.22 eV and resolved up to 7 photons per pulse, both greatly improved from previously reported results at 1550 nm wavelength using MKIDs. Further improvements are possible by optimizing the optical coupling to maximize photon absorption into the inductive absorber.

physics.ins-det

Measuring the electron neutrino mass with improved sensitivity: the HOLMES experiment

HOLMES is a new experiment aiming at directly measuring the neutrino mass with a sensitivity below 2 eV. HOLMES will perform a calorimetric measurement of the energy released in the decay of $^{163}$Ho. The calorimetric measurement eliminates systematic uncertainties arising from the use of external beta sources, as in experiments with spectrometers. This measurement was proposed in 1982 by A. De Rujula and M. Lusignoli, but only recently the detector technological progress has allowed to design a sensitive experiment. HOLMES will deploy a large array of low temperature microcalorimeters with implanted $^{163}$Ho nuclei. HOLMES, besides being an important step forward in the direct neutrino mass measurement with a calorimetric approach, will also establish the potential of this approach to extend the sensitivity down to 0.1 eV and lower. In its final configuration HOLMES will collect about $3\cdot 10^{13}$ decays with 1000 detectors characterized by an instrumental energy resolution of the order of few eV and a time resolution of few microseconds. To embed the $^{163}$Ho into the gold absorbers a custom mass separator ion implanter is being developed. The detectors used for the HOLMES experiment will be Mo/Cu bilayers TESs (Transition Edge Sensors) on SiN$_x$ membrane with gold absorbers. Microwave multiplexed rf-SQUIDs are the best available technique to read out large array of such detectors. An extensive R&D activity is in progress in order to maximize the multiplexing factor while preserving the performances of the individual detectors. The current activities are focused on the the single detector performances optimization and on the $^{163}$Ho isotope production and embedding. A preliminary measurement of a sub-array of $4\times 16$ detectors is planned late in 2017. In this contribution we present the HOLMES project with its technical challenges, its status and perspectives.

physics.ins-det

Algorithms for Identification of Nearly-Coincident Events in Calorimetric Sensors

For experiments with high arrival rates, reliable identification of nearly-coincident events can be crucial. For calorimetric measurements to directly measure the neutrino mass such as HOLMES, unidentified pulse pile-ups are expected to be a leading source of experimental error. Although Wiener filtering can be used to recognize pile-up, it suffers errors due to pulse-shape variation from detector nonlinearity, readout dependence on sub-sample arrival times, and stability issues from the ill-posed deconvolution problem of recovering Dirac delta-functions from smooth data. Due to these factors, we have developed a processing method that exploits singular value decomposition to (1) separate single-pulse records from piled-up records in training data and (2) construct a model of single-pulse records that accounts for varying pulse shape with amplitude, arrival time, and baseline level, suitable for detecting nearly-coincident events. We show that the resulting processing advances can reduce the required performance specifications of the detectors and readout system or, equivalently, enable larger sensor arrays and better constraints on the neutrino mass.

physics.data-an

HOLMES - The Electron Capture Decay of 163Ho to Measure the Electron Neutrino Mass with sub-eV sensitivity

The European Research Council has recently funded HOLMES, a new experiment to directly measure the neutrino mass. HOLMES will perform a calorimetric measurement of the energy released in the decay of 163Ho. The calorimetric measurement eliminates systematic uncertainties arising from the use of external beta sources, as in experiments with beta spectrometers. This measurement was proposed in 1982 by A. De Rujula and M. Lusignoli, but only recently the detector technological progress allowed to design a sensitive experiment. HOLMES will deploy a large array of low temperature microcalorimeters with implanted 163Ho nuclei. The resulting mass sensitivity will be as low as 0.4 eV. HOLMES will be an important step forward in the direct neutrino mass measurement with a calorimetric approach as an alternative to spectrometry. It will also establish the potential of this approach to extend the sensitivity down to 0.1 eV. We outline here the project with its technical challenges and perspectives.

physics.ins-det

Transition-Edge Sensors for Particle Induced X-ray Emission Measurements

In this paper we present a new measurement setup, where a transitionedge sensor detector array is used to detect X-rays in particle induced X-ray emission measurements with a 2 MeV proton beam. Transition-edge sensors offer orders of magnitude improvement in energy resolution compared to conventional silicon or germanium detectors, making it possible to recognize spectral lines in materials analysis that have previously been impossible to resolve, and to get chemical information from the elements. Our sensors are cooled to the operation temperature (65 mK) with a cryogen-free adiabatic demagnetization refrigerator, which houses a specially designed X-ray snout that has a vacuum tight window to couple in the radiation. For the best pixel, the measured instrumental energy resolution was 3.06 eV full width at half maximum at 5.9 keV.We discuss the current status of the project, benefits of transition-edge sensors when used in particle induced X-ray emission spectroscopy, and the results from the first measurements.

physics.ins-det