SearcharxivSearch

arXiv subjects

J. Vicha

Publications and source records attributed to J. Vicha.

6 recordsLinked to original sources

Analysis of commissioning data from SST-1M : A Prototype of Single-Mirror Small Size Telescope

SST-1M is a prototype of a single-mirror Small Size Telescope developed by a consortium of institutes from Poland, Switzerland and the Czech Republic. With a wide field of view of 9 degrees, SST-1Ms are designed to detect gamma-rays in the energy range between 1 and 300 TeV. The design of the SST-1M follows the Davies-Cotton concept, with a 9.42m2 multi-segment mirror. SST-1M is equipped with DigiCam camera, which features a fully digital readout and trigger system using 250 MHz ADC, and a compact Photo-Detector Plane (PDP) composed of 1296 pixels, each made of a hexagonal light guide coupled to silicone photomultipliers (SiPM). Two SST-1M telescopes are currently being commissioned at the Ondrejov Observatory in the Czech Republic, where they are successfully observing Cerenkov events in stereo. This contribution will present an overview of calibration strategies and performance evaluation based on data collected at the observatory.

astro-ph.IM

On the Combined Analysis of Muon Shower Size and Depth of Shower Maximum

The mass composition of ultra-high energy cosmic rays can be studied from the distributions of the depth of shower maximum and/or the muon shower size. Here, we study the dependence of the mean muon shower size on the depth of shower maximum in detail. Air showers induced by protons and iron nuclei were simulated with two models of hadronic interactions already tuned with LHC data (run I-II). The generated air showers were combined to obtain various types of mass composition of the primary beam. We investigated the shape of the functional dependence of the mean muon shower size on the depth of shower maximum and its dependency on the composition mixture. Fitting this dependence we can derive the primary fractions and the muon rescaling factor with a statistical uncertainty at a level of few percent. The difference between the reconstructed primary fractions is below 20% when different models are considered. The difference in the muon shower size between the two models was observed to be around 6%.

astro-ph.IM

Data Processing at the Pierre Auger Observatory

Cosmic-ray particles with ultra-high energies (above $10^{18}$ eV) are studied through the properties of extensive air showers which they initiate in the atmosphere. The Pierre Auger Observatory detects these showers with unprecedented exposure and precision and the collected data are processed via dedicated software codes. Monte Carlo simulations of extensive air showers are very computationally expensive, especially at the highest energies and calculations are performed on the GRID for this purpose. The processing of measured and simulated data is described, together with a brief list of physics results which have been achieved.

astro-ph.IM

Signal Attenuation Curve for Different Surface Detector Arrays

Modern cosmic ray experiments consisting of large array of particle detectors measure the signals of electromagnetic or muon components or their combination. The correction for an amount of atmosphere passed is applied to the surface detector signal before its conversion to the shower energy. Either Monte Carlo based approach assuming certain composition of primaries or indirect estimation using real data and assuming isotropy of arrival directions can be used. Toy surface arrays of different sensitivities to electromagnetic and muon components are assumed in MC simulations to study effects imposed on attenuation curves for varying composition or possible high energy anisotropy. The possible sensitivity of the attenuation curve to the mass composition is also tested for different array types focusing on a future apparatus that can separate muon and electromagnetic component signals.

astro-ph.HE

On the methods to determine signal attenuation curve for different surface arrays

Large surface arrays of current cosmic ray experiments measure the signals of electromagnetic or muonic components or their combination. The correction to the zenith angle (the attenuation curve) has to be taken into account before the signal is converted to the shower energy. Either Monte Carlo simulations or indirect estimation using collected data (Constant Intensity Cut method) can be used. However, the assumptions of composition or isotropy used for the determination of the attenuation curve can still influence the final physics results such as the energy spectrum, or modify anisotropy searches and composition analysis. Using simplified Toy Monte Carlo with an output from CORSIKA simulations we try to find several examples of what kind of effects can be caused by the methods of inferring the attenuation curve. Surface arrays of different sensitivities to electromagnetic and muonic components were considered.

astro-ph.HE

Testing chemical composition of highest energy comic rays

We study basic characteristics of distributions of the depths of shower maximum in air showers caused by cosmic rays with the highest energies. The consistency between their average values and widths, and their energy dependences are discussed within a simple phenomenological model of shower development independently of assumptions about detailed features of high--energy interactions. It is shown that reliable information on primary species can be derived within a partition method. We present examples demonstrating implications for the changes in mass composition of primary cosmic rays.

astro-ph.HE