SearcharxivSearch

arXiv subjects

J. Voigt

Publications and source records attributed to J. Voigt.

At least 19 recordsLinked to original sources

Proposal for a new spectrometer at ESS: Njord and Remora

Many of the most interesting scientific subjects are also the hardest to study with neutrons. Metal-organic frameworks, organic superconductors, quantum magnets, pressure-tuned materials, are systems where the relevant signals are weak, the samples are tiny, or the experiments need extreme sample environments such as pressure cells and high-field cryomagnets. Existing instruments often run into practical limits before the science is exhausted. For some questions the samples are simply too small; for others, the signal is buried in background or the required measurement time becomes prohibitive. This is both a scientific opportunity and a challenge for the European neutron scattering community. We present Njord and Remora as a paired instrument concept for the European Spallation Source (ESS). The proposal focuses on two linked problems: important science cases are being limited by neutron flux and sample geometry, and the community also needs more beamtime. Njord addresses the first by pushing the available brightness into a tightly focused beam, while Remora uses the remaining spectral window to add a complementary spectrometer on the same beamport.

physics.ins-det

Generating a highly uniform magnetic field inside the magnetically shielded room of the n2EDM experiment

We present a coil system designed to generate a highly uniform magnetic field for the n2EDM experiment at the Paul Scherrer Institute. It consists of a main $B_0$ coil and a set of auxiliary coils mounted on a cubic structure with a side length of 273 cm, inside a large magnetically shielded room (MSR). We have assembled this system and characerized its performances with a mapping robot. The apparatus is able to generate a 1 $μ$ T vertical field with a relative root mean square deviation $σ$ ($B_z$)/$B_z$ = 3 $\times$ $10^{-5}$ over the volume of interest, a cylinder of radius 40 cm and height 30 cm. This level of uniformity overcomes the n2EDM requirements, allowing a measurement of the neutron Electric Dipole Moment with a sensitivity better than 1 $\times$ $10^{-27}$ ecm.

physics.ins-det

Achieving ultra-low and -uniform residual magnetic fields in a very large magnetically shielded room for fundamental physics experiments

High-precision searches for an electric dipole moment of the neutron (nEDM) require stable and uniform magnetic field environments. We present the recent achievements of degaussing and equilibrating the magnetically shielded room (MSR) for the n2EDM experiment at the Paul Scherrer Institute. We present the final degaussing configuration that will be used for n2EDM after numerous studies. The optimized procedure results in a residual magnetic field that has been reduced by a factor of two. The ultra-low field is achieved with the full magnetic-field-coil system, and a large vacuum vessel installed, both in the MSR. In the inner volume of ~1.4 m^3, the field is now more uniform and below 300 pT. In addition, the procedure is faster and dissipates less heat into the magnetic environment, which in turn, reduces its thermal relaxation time from 12 h down to ~1.5 h.

physics.ins-det

The design of the n2EDM experiment

We present the design of a next-generation experiment, n2EDM, currently under construction at the ultracold neutron source at the Paul Scherrer Institute (PSI) with the aim of carrying out a high-precision search for an electric dipole moment of the neutron. The project builds on experience gained with the previous apparatus operated at PSI until 2017, and is expected to deliver an order of magnitude better sensitivity with provision for further substantial improvements. An overview is given of the experimental method and setup, the sensitivity requirements for the apparatus are derived, and its technical design is described.

physics.ins-det

Revisiting $^{129}$Xe electric dipole moment measurements applying a new global phase fitting approach

By measuring the nuclear magnetic spin precession frequencies of polarized $^{129}$Xe and $^{3}$He, a new upper limit on the $^{129}$Xe atomic electric dipole moment (EDM) $ d_\mathrm{A} (^{129}\mathrm{Xe})$ was reported in Phys. Rev. Lett. 123, 143003 (2019). Here, we propose a new evaluation method based on global phase fitting (GPF) for analyzing the continuous phase development of the $^{3}$He-$^{129}$Xe comagnetometer signal. The Cramer-Rao Lower Bound on the $^{129}$Xe EDM for the GPF method is theoretically derived and shows the potential benefit of our new approach. The robustness of the GPF method is verified with Monte-Carlo studies. By optimizing the analysis parameters and adding data that could not be analyzed with the former method, we obtain a result of $d_\mathrm{A} (^{129}\mathrm{Xe}) = 1.1 \pm 3.6~\mathrm{(stat)} \pm 2.0~\mathrm{(syst)} \times 10^{-28}~ e~\mathrm{cm}$ in an unblinded analysis. For the systematic uncertainty analyses, we adopted all methods from the aforementioned PRL publication except the comagnetometer phase drift, which can be omitted using the GPF method. The updated null result can be interpreted as a new upper limit of $| d_\mathrm{A} (^{129}\mathrm{Xe}) | < 8.3 \times 10^{-28}~e~\mathrm{cm}$ at the 95\% C.L.

physics.atom-ph

Surface resonance of the (2$\times$1) reconstructed lanthanum hexaboride (001)-cleavage plane: a combined STM and DFT study

We performed a combined study of the (001)-cleavage plane of lanthanum hexaboride (LaB$_\text{6}$) using scanning tunneling microscopy (STM) and density functional theory (DFT). Experimentally, we found a (2$\times$1) reconstructed surface on a local scale. The reconstruction is only short-range ordered and tends to order perpendicularly to step edges. At larger distances from surface steps, the reconstruction evolves to a labyrinth-like pattern. These findings are supported by low-energy electron diffraction (LEED) experiments. Slab calculations within the framework of DFT shows that the atomic structure consists of parallel lanthanum chains on top of boron octahedra. Scanning tunneling spectroscopy (STS) shows a prominent spectral feature at -0.6 eV. Using DFT, we identify this structure as a surface resonance of the (2$\times$1) reconstructed LaB$_\text{6}$ (100)-surface which is dominated by boron dangling bond-states and lanthanum d-states.

cond-mat.mes-hall

Measurement of the permanent electric dipole moment of the neutron

We present the result of an experiment to measure the electric dipole moment (EDM) of the neutron at the Paul Scherrer Institute using Ramsey's method of separated oscillating magnetic fields with ultracold neutrons (UCN). Our measurement stands in the long history of EDM experiments probing physics violating time reversal invariance. The salient features of this experiment were the use of a Hg-199 co-magnetometer and an array of optically pumped cesium vapor magnetometers to cancel and correct for magnetic field changes. The statistical analysis was performed on blinded datasets by two separate groups while the estimation of systematic effects profited from an unprecedented knowledge of the magnetic field. The measured value of the neutron EDM is $d_{\rm n} = (0.0\pm1.1_{\rm stat}\pm0.2_{\rm sys})\times10^{-26}e\,{\rm cm}$.

hep-ex

New Limit on the Permanent Electric Dipole Moment of $^{129}$Xe using $^{3}$He Comagnetometry and SQUID Detection

We report results of a new technique to measure the electric dipole moment of $^{129}$Xe with $^3$He comagnetometry. Both species are polarized using spin-exchange optical pumping, transferred to a measurement cell, and transported into a magnetically shielded room, where SQUID magnetometers detect free precession in applied electric and magnetic fields. The result from a one week measurement campaign in 2017 and a 2.5 week campaign in 2018, combined with detailed study of systematic effects, is $d_A(^{129}\mathrm{Xe}) = (1.4 \pm 6.6_\mathrm{stat} \pm 2.0_\mathrm{syst})\times10^{-28}~e\,\mathrm{cm}$. This corresponds to an upper limit of $|d_A(^{129}\mathrm{Xe})| < 1.4 \times 10^{-27} ~e\,\mathrm{cm}~(95\%~\mathrm{CL})$, a factor of five more sensitive than the limit set in 2001.

physics.atom-ph

The n2EDM experiment at the Paul Scherrer Institute

We present the new spectrometer for the neutron electric dipole moment (nEDM) search at the Paul Scherrer Institute (PSI), called n2EDM. The setup is at room temperature in vacuum using ultracold neutrons. n2EDM features a large UCN double storage chamber design with neutron transport adapted to the PSI UCN source. The design builds on experience gained from the previous apparatus operated at PSI until 2017. An order of magnitude increase in sensitivity is calculated for the new baseline setup based on scalable results from the previous apparatus, and the UCN source performance achieved in 2016.

physics.ins-det

A new measurement of the permanent electric dipole moment of $^{129}$Xe using $^{3}$He comagnetometry and SQUID detection

We describe a new technique to measure the EDM of $^{129}$Xe with $^3$He comagnetometry. Both species are polarized using spin-exchange optical pumping, transferred to a measurement cell, and transported into a magnetically shielded room, where SQUID magnetometers detect free precession in applied electric and magnetic fields. The result of a one week run combined with a detailed study of systematic effects is $d_A(^{129}\mathrm{Xe}) = (0.26 \pm 2.33_\mathrm{stat} \pm 0.72_\mathrm{syst})\times10^{-27}~e\,\mathrm{cm}$. This corresponds to an upper limit of $|d_A(^{129}\mathrm{Xe})| < 4.81\times 10^{-27} ~e\,\mathrm{cm}~(95\%~\mathrm{CL})$, a factor of 1.4 more sensitive than the previous limit.

physics.atom-ph

nEDM experiment at PSI: data-taking strategy and sensitivity of the dataset

We report on the strategy used to optimize the sensitivity of our search for a neutron electric dipole moment at the Paul Scherrer Institute. Measurements were made upon ultracold neutrons stored within a single chamber at the heart of our apparatus. A mercury cohabiting magnetometer together with an array of cesium magnetometers were used to monitor the magnetic field, which was controlled and shaped by a series of precision field coils. In addition to details of the setup itself, we describe the chosen path to realize an appropriate balance between achieving the highest statistical sensitivity alongside the necessary control on systematic effects. The resulting irreducible sensitivity is better than 1*10-26 ecm. This contribution summarizes in a single coherent picture the results of the most recent publications of the collaboration.

physics.ins-det

Perturbations of Positive Semigroups on AM-Spaces

We consider positive perturbations of positive semigroups on AM-spaces and prove a result which is the dual counterpart of a famous perturbation result of Desch in AL-spaces. As an application we consider unbounded perturbations of the shift semigroup.

math.FA

Design and performance of an absolute $^3$He/Cs magnetometer

We report on the design and performance of a highly sensitive combined $^3$He/Cs magnetometer for the absolute measurement of magnetic fields. The magnetometer relies on the magnetometric detection of the free spin precession of nuclear spin polarized $^3$He gas by optically pumped cesium magnetometers. We plan to deploy this type of combined magnetometer in an experiment searching for a permanent electric dipole moment of ultracold neutrons at the Paul Scherrer Institute (Switzerland). A prototype magnetometer was built at the University of Fribourg (Switzerland) and tested at Physikalisch-Technische Bundesanstalt (Berlin, Germany). We demonstrate that the combined magnetometer allows Cramér-Rao- limited field determinations with recording times in the range of $\sim 500\mathrm{s}$, measurements above $500\mathrm{s}$ being limited by the stability of the applied magnetic field. % With a $100\mathrm{s}$ recording time we were able to perform an absolute measurement of a magnetic field of $\approx1\mathrm{μT}$ with a standard uncertainty of $ΔB\sim60\mathrm{fT}$, corresponding to $ΔB/B<$6$\times$10$^{-8}$.

physics.atom-ph

A large-scale magnetic shield with 10^6 damping at mHz frequencies

We present a magnetically shielded environment with a damping factor larger than one million at the mHz frequency regime and an extremely low field and gradient over an extended volume. This extraordinary shielding performance represents an improvement of the state of the art in damping the difficult regime of very low-frequency distortions by more than an order of magnitude. This technology enables a new generation of high precision measurements in fundamental physics and metrology, including searches for new physics far beyond the reach of accelerator-based experiments. We discuss the technical realization of the shield with its improvements in design.

physics.ins-det

Constraining interactions mediated by axion-like particles with ultracold neutrons

We report a new limit on a possible short range spin-dependent interaction from the precise measurement of the ratio of Larmor precession frequencies of stored ultracold neutrons and $^{199}$Hg atoms confined in the same volume. The measurement was performed in a $\sim$1$μ$ T vertical magnetic holding field with the apparatus searching for a permanent electric dipole moment of the neutron at the Paul Scherrer Institute. A possible coupling between freely precessing polarized neutron spins and unpolarized nucleons of the wall material can be investigated by searching for a tiny change of the precession frequencies of neutron and mercury spins. Such a frequency change can be interpreted as a consequence of a short range spin-dependent interaction that could possibly be mediated by axions or axion-like particles. The interaction strength is proportional to the CP violating product of scalar and pseudoscalar coupling constants $g_Sg_P$. Our result confirms limits from complementary experiments with spin-polarized nuclei in a model-independent way. Limits from other neutron experiments are improved by up to two orders of magnitude in the interaction range of $10^{-6}<λ<10^{-4}$ m.

hep-ex

A measurement of the neutron to 199Hg magnetic moment ratio

The neutron gyromagnetic ratio has been measured relative to that of the 199Hg atom with an uncertainty of 0.8 ppm. We employed an apparatus where ultracold neutrons and mercury atoms are stored in the same volume and report the result $γ_{\rm n}/γ_{\rm Hg} = 3.8424574(30)$.

nucl-ex

Dynamic stabilization of the magnetic field surrounding the neutron electric dipole moment spectrometer at the Paul Scherrer Institute

The Surrounding Field Compensation (SFC) system described in this work is installed around the four-layer Mu-metal magnetic shield of the neutron electric dipole moment spectrometer located at the Paul Scherrer Institute. The SFC system reduces the DC component of the external magnetic field by a factor of about 20. Within a control volume of approximately 2.5m x 2.5m x 3m disturbances of the magnetic field are attenuated by factors of 5 to 50 at a bandwidth from $10^{-3}$ Hz up to 0.5 Hz, which corresponds to integration times longer than several hundreds of seconds and represent the important timescale for the nEDM measurement. These shielding factors apply to random environmental noise from arbitrary sources. This is achieved via a proportional-integral feedback stabilization system that includes a regularized pseudoinverse matrix of proportionality factors which correlates magnetic field changes at all sensor positions to current changes in the SFC coils.

physics.ins-det

A magnetically shielded room with ultra low residual field and gradient

A versatile and portable magnetically shielded room with a field of (700 \pm 200) pT within a central volume of 1m x 1m x 1m and a field gradient less than 300 pT/m is described. This performance represents more than a hundred-fold improvement of the state of the art for a two-layer magnetic shield and provides an environment suitable for a next generation of precision experiments in fundamental physics at low energies; in particular, searches for electric dipole moments of fundamental systems and tests of Lorentz-invariance based on spin-precession experiments. Studies of the residual fields and their sources enable improved design of future ultra-low gradient environments and experimental apparatus.