SearcharxivSearch

arXiv subjects

J. Volk

Publications and source records attributed to J. Volk.

14 recordsLinked to original sources

Picosecond Femtojoule Resistive Switching in Nanoscale VO$_{2}$ Memristors

Beyond-Moore computing technologies are expected to provide a sustainable alternative to the von Neumann approach not only due to their down-scaling potential but also via exploiting device-level functional complexity at the lowest possible energy consumption. The dynamics of the Mott transition in correlated electron oxides, such as vanadium dioxide, has been identified as a rich and reliable source of such functional complexity. However, its full potential in high-speed and low-power operation has been largely unexplored. We fabricated nanoscale VO$_{2}$ devices embedded in a broad-band test circuit to study the speed and energy limitations of their resistive switching operation. Our picosecond time-resolution, real-time resistive switching experiments and numerical simulations demonstrate that tunable low-resistance states can be set by the application of 20~ps long, $<$1.7~V amplitude voltage pulses at 15~ps incubation times and switching energies starting from a few femtojoule. Moreover, we demonstrate that at nanometer-scale device sizes not only the electric field induced insulator-to-metal transition, but also the thermal conduction limited metal-to-insulator transition can take place at timescales of 100's of picoseconds. These orders of magnitude breakthroughs open the route to the design of high-speed and low-power dynamical circuits for a plethora of neuromorphic computing applications from pattern recognition to numerical optimization.

cond-mat.mes-hall

Optical-microwave pump-probe studies of electronic properties in novel materials

Combined microwave-optical pump-probe methods are emerging to study the quantum state of spin qubit centers and the charge dynamics in semiconductors. A major hindrance is the limited bandwidth of microwave irradiation/detection circuitry which could be overcome with the use of broadband coplanar waveguides (CPW). We present the development and performance characterization of two spectrometers: an optically detected magnetic resonance spectrometer (ODMR) and a microwave detected photoconductivity measurement. In the first method light serves as detection and microwaves excite the investigated medium, while in the second the roles are interchanged. The performance is demonstrated by measuring ODMR maps on the nitrogen-vacancy center in diamond and time resolved photoconductivity in p-doped silicon. The results demonstrate both an efficient coupling of the microwave irradiation to the samples as well as an excellent sensitivity for minute changes in sample conductivity.

physics.app-ph

Ultrafast sensing of photoconductivity decay using microwave resonators

Microwave reflectance probed photoconductivity (or $μ$-PCD) measurement represents a contactless and non-invasive method to characterize impurity content in semiconductors. Major drawbacks of the method include a difficult separation of reflectance due to dielectric and conduction effects and that the $μ$-PCD signal is prohibitively weak for highly conducting samples. Both of these limitations could be tackled with the use of microwave resonators due to the well-known sensitivity of resonator parameters to minute changes in the material properties combined with a null measurement. A general misconception is that time resolution of resonator measurements is limited beyond their bandwidth by the readout electronics response time. While it is true for conventional resonator measurements, such as those employing a frequency sweep, we present a time-resolved resonator parameter readout method which overcomes these limitations and allows measurement of complex material parameters and to enhance $μ$-PCD signals with the ultimate time resolution limit being the resonator time constant. This is achieved by detecting the transient response of microwave resonators on the timescale of a few 100 ns \emph{during} the $μ$-PCD decay signal. The method employs a high-stability oscillator working with a fixed frequency which results in a stable and highly accurate measurement.

physics.app-ph

RF system for the MICE demonstration of ionization cooling

Muon accelerators offer an attractive option for a range of future particle physics experiments. They can enable high energy (TeV+) high energy lepton colliders whilst mitigating the difficulty of synchrotron losses, and can provide intense beams of neutrinos for fundamental physics experiments investigating the physics of flavor. The method of production of muon beams results in high beam emittance which must be reduced for efficient acceleration. Conventional emittance control schemes take too long, given the very short (2.2 microsecond) rest lifetime of the muon. Ionisation cooling offers a much faster approach to reducing particle emittance, and the international MICE collaboration aims to demonstrate this technique for the first time. This paper will present the MICE RF system and its role in the context of the overall experiment.

physics.acc-ph

Hydrostatic Level Sensors as High Precision Ground Motion Instrumentation for Tevatron and Other Energy Frontier Accelerators

Particle accelerators pushed the limits of our knowledge in search of the answers to most fundamental questions about micro-world and our Universe. In these pursuits, accelerators progressed to higher and higher energies and particle beam intensities as well as increasingly smaller and smaller beam sizes. As the result, modern existing and planned energy frontier accelerators demand very tight tolerances on alignment and stability of their elements: magnets, accelerating cavities, vacuum chambers, etc. In this article we describe the instruments developed for and used in such accelerators as Fermilab's Tevatron (FNAL, Batavia, IL USA) and for the studies toward an International Linear Collider (ILC). The instrumentation includes Hydrostatic Level Sensors (HLS) for very low frequency measurements. We present design features of the sensors, outline their technical parameters, describe test and calibration procedures and discuss different regimes of operation. Experimental results of the ground motion measurements with these detectors will be presented in subsequent paper.

physics.acc-ph

Study of the rare hyperon decay Omega \to Xi π^+ π^-

We report a new measurement of the decay Ω^- \to Ξ^- π^+ π^- with 76 events and a first observation of the decay Ω^+ \to Ξ^+ π^+ π^- with 24 events, yielding a combined branching ratio (3.74 ^{+0.67}_{-0.56}) \times 10^{-4}. This represents a factor 25 increase in statistics over the best previous measurement. No evidence is seen for CP violation, with B(Ω^- \to Ξ^- π^+ π^-)=4.04^{+0.83}_{-0.71} \times 10^{-4} and B(Ω^+ \to Ξ^+ π^+ π^-)=3.15^{+1.12}_{-0.89} \times 10^{-4}. Contrary to theoretical expectation, we see little evidence for the decays Ω^- \to Ξ_{1530}^{*0} π^- and Ω^+ \to Ξ_{1530}^{*0} π^+ and place a 90% C.L. upper limit on the combined branching ratio B(Ω^-(Ω^+) \to Ξ^{*0}_{1530}(Ξ^{*0}_{1530}) π^\mp)<7.0 \times 10^{-5}.

hep-ex

Search for the Lepton-Number-Violating Decay $Ξ^- \to p μ^- μ^-$

A sensitive search for the lepton-number-violating decay $Ξ^-\to p μ^-μ^-$ has been performed using a sample of $\sim10^9$ $Ξ^-$ hyperons produced in 800 GeV/$c$ $p$-Cu collisions. We obtain $\mathcal{B}(Ξ^-\to p μ^-μ^-)< 4.0\times 10^{-8}$ at 90% confidence, improving on the best previous limit by four orders of magnitude.

hep-ex

Observation of Parity Violation in the Omega-minus -> Lambda + K-minus Decay

The alpha decay parameter in the process Omega-minus -> Lambda + K-minus has been measured from a sample of 4.50 million unpolarized Omega-minus decays recorded by the HyperCP (E871) experiment at Fermilab and found to be [1.78 +/- 0.19(stat) +/- 0.16(syst)]{\times}10^{-2}. This is the first unambiguous evidence for a nonzero alpha decay parameter, and hence parity violation, in the Omega-minus -> Lambda + K-minus decay.

hep-ex

delta S = 2 nonleptonic hyperon decays

A sensitive search for the rare decays Ω^- \to Λπ^- and Ξ^0 \to p π^- has been performed using data from the 1997 run of the HyperCP (Fermilab E871) experiment. Limits on other such processes do not exclude the possibility of observable rates for |ΔS| = 2 nonleptonic hyperon decays, provided the decays occur through parity-odd operators. We obtain the branching-fraction limits B(Ω^- \to Λπ^-)< 2.9 x 10^{-6} and B(Ξ^0 \to p π^-)< 8.2 x 10^{-6}, both at 90% confidence level.

hep-ex

Measurement of the Alpha Asymmetry Parameter for the Omega- to Lambda K- Decay

We have measured the alpha parameter of the Omega- to Lambda K- decay using data collected with the HyperCP spectrometer during the 1997 fixed-target run at Fermilab. Analyzing a sample of 0.96 million Omega- to Lambda K^-, Lambda to p pi- decays, we obtain alpha_Omega*alpha_Lambda = [1.33+/-0.33(stat)+/-0.52(syst)] x 10^{-2}. With the accepted value of alpha_Lambda, alpha_Omega is found to be [2.07+/-0.51(stat)+/-0.81(syst)] x 10^{-2}.

hep-ex

Evidence for the Decay Sigma+ -> p mu+ mu-

We report the first evidence for the decay Sigma+ -> p mu+ mu- from data taken by the HyperCP experiment(E871) at Fermilab. Based on three observed events, the branching ratio is B(Sigma+ -> p,mu+,mu-) = [8.6 +6.6,-5.4(stat) +/-5.5(syst)] x 10**-8. The narrow range of dimuon masses may indicate that the decay proceeds via a neutral intermediate state, Sigma+ -> p P0, P0 -> mu+ mu-, with a P0 mass of 214.3 +/- 0.5 MeV/c**2 and branching ratio B(Sigma+ -> p P0; P0 -> mu+ mu-) = [3.1 +2.4,-1.(stat) +/-1.5(syst)] x 10**-8.

hep-ex

Search for CP Violation in Charged-Xi and Lambda Hyperon Decays

We have compared the proton and antiproton angular distributions in 117 million Xi-minus -> Lambda + pi-minus -> proton + pi-minus + pi-minus and 41 million anti-Xi-minus -> anti-Lamba + pi-plus -> antiproton + pi-plus + pi-plus decays using a subset of the data from the HyperCP experiment (E871) at Fermilab. We find no evidence of CP violation, with the direct-CP-violating parameter $A_{ΞΛ} = \frac{α_Ξα_Λ - \barα_Ξ\barα_Λ}{α_Ξα_Λ + \barα_Ξ\barα_Λ} = [0.0+/-5.1(stat)+/-4.4(syst)]{\times}10^{-4}$.

hep-ex

High Statistics Search for the Theta+(1.54) Pentaquark State

We have searched for Theta+(1.54) -> K0,p decays using data from the 1999 run of the HyperCP experiment at Fermilab. We see no evidence for a narrow peak in the K0,p mass distribution near 1.54 GeV/c among 106,000 K0,p candidates, and obtain an upper limit for the fraction of Theta+(1.54) to K0,p candidates of <0.3% at 90% confidence.

hep-ex

HyperCP: A high-rate spectrometer for the study of charged hyperon and kaon decays

The HyperCP experiment (Fermilab E871) was designed to search for rare phenomena in the decays of charged strange particles, in particular CP violation in $Ξ$ and $Λ$ hyperon decays with a sensitivity of $10^{-4}$. Intense charged secondary beams were produced by 800 GeV/c protons and momentum-selected by a magnetic channel. Decay products were detected in a large-acceptance, high-rate magnetic spectrometer using multiwire proportional chambers, trigger hodoscopes, a hadronic calorimeter, and a muon-detection system. Nearly identical acceptances and efficiencies for hyperons and antihyperons decaying within an evacuated volume were achieved by reversing the polarities of the channel and spectrometer magnets. A high-rate data-acquisition system enabled 231 billion events to be recorded in twelve months of data-taking.

hep-ex