SearcharxivSearch

arXiv subjects

J. W. Chapman

Publications and source records attributed to J. W. Chapman.

13 recordsLinked to original sources

Design of a Time-to-Digital Converter ASIC and a mini-DAQ system for the Phase-2 Upgrade of the ATLAS Monitored Drift Tube detector

We present the second prototype of a time-to-digital (TDC) ASIC for the upgrade of the ATLAS Monitored Drift Tube (MDT) detector for High-Luminosity LHC operations. Compared to the first prototype, triple modular redundancy has been implemented for the configuration and flow control logic. The total power consumption is increased by less than 10 mW while achieving the same time resolution and channel uniformity. A mini-DAQ system has been built to verify the front-end electronics chain with the new prototype together with other ASICs and boards in triggered mode. Cosmic ray tests with a small-diameter MDT chamber indicate that the configuration and data transmission of the readout electronics perform well. It is expected that this prototype design will be used in the final production.

physics.ins-det

Design and performance of a TDC ASIC for the upgrade of the ATLAS Monitored Drift Tube detector

We present the prototype of a time-to-digital (TDC) ASIC for the upgrade of the ATLAS Monitored Drift Tube (MDT) detector for high-luminosity LHC operation. This ASIC is based on a previously submitted demonstrator ASIC designed for timing performance evaluation, and includes all features necessary for the various operation modes, as well as the migration to the TSMC 130 nm CMOS technology. We present the TDC design with the emphasis on added features and performance optimization. Tests of the timing performance demonstrate that this ASIC meets the design specifications. The TDC has a bin size of about 780 ps, and a timing bin variations within 40 ps for all 24 channels with leading and trailing edge digitization, while the power consumption has been limited to 250 mW, corresponding to a consumption of about 5.2 mW per edge measurement.

physics.ins-det

Operation and performance of microhexcavity pixel detector in gas discharge and avalanche mode

The Microhexcavity Panel ( muHex) is a novel gaseous micropattern particle detector comprised of a dense array of close-packed hexagonal pixels, each operating as an independent detection unit for ionizing radiation. It is a second generation detector derived from plasma panel detectors and microcavity detectors. The muHex is under development to be deployed as a scalable, fast timing (ns) and hermetically sealed gaseous tracking detector with high rate ( > 100 KHz/cm^2 ) capability. The devices reported here were fabricated as 16 x 16 pixel arrays of 2 mm edge-to-edge, 1 mm deep hexagonal cells embedded in a thin, 1.4 mm glass-ceramic wafer. Cell walls are metalized cathodes, connected to high voltage bus lines through conductive vias. Anodes are small, 457 micron diameter metal discs screen printed on the upper substrate. The detectors are filled with an operating gas to near 1 atm and then closed with a shut-off valve. They have been operated in both avalanche mode and gas discharge devices, producing mV to volt level signals with about 1 to 3 ns rise times. Operation in discharge mode is enabled by high impedance quench resistors on the high voltage bus at each pixel site. Results indicate that each individual pixel behaves as an isolated detection unit with high single pixel intrinsic efficiency to both beta's from radioactive sources and to cosmic ray muons. Continuous avalanche mode operation over several days at hit rates over 300 KHz/cm^2 with no gas flow have been observed. Measurements of pixel isolation, timing response, efficiency, hit rate and rate stability are reported.

physics.ins-det

Design of a Trigger Data Serializer ASIC for the Upgrade of the ATLAS Forward Muon Spectrometer

The small-strip Thin Gap Chamber (sTGC) will be used for both triggering and precision tracking purposes in the upgrade of the ATLAS forward muon spectrometer. Both sTGC pad and strip detectors are readout by a Trigger Data Serializer (TDS) ASIC in the trigger path. This ASIC has two operation modes to prepare trigger data from pad and strip detectors respectively. The pad mode (pad-TDS) collects the firing status for up to 104 pads from one detector layer and transmits the data at 4.8 Gbps to the pad trigger extractor every 25 ns. The pad trigger extractor collects pad-TDS data from eight detector layers and defines a region of interest along the path of a muon candidate. In the strip mode (strip-TDS), the deposited charges from up to 128 strips are buffered, time-stamped, and a trigger matching procedure is performed to read out strips underneath the region of interest. The strip-TDS output is also transmitted at 4.8 Gbps to the following FPGA processing circuits. Details about the ASIC design and test results are presented in this paper.

physics.ins-det

FPGA Implementation of a Fixed Latency Scheme in a Signal Packet Router for the Upgrade of ATLAS Forward Muon Trigger Electronics

We propose a new fixed latency scheme for Xilinx gigabit transceivers that will be used in the upgrade of the ATLAS forward muon spectrometer at the Large Hadron Collider. The fixed latency scheme is implemented in a 4.8 Gbps link between a frontend data serializer ASIC and a packet router. To achieve fixed latency, we use IO delay and dedicated carry in resources in a Xilinx FPGA, while minimally relying on the embedded features of the FPGA transceivers. The scheme is protocol independent and can be adapted to FPGA from other vendors with similar resources. This paper presents a detailed implementation of the fixed latency scheme, as well as simulations of the real environment in the ATLAS forward muon region.

physics.ins-det

Characterization of a Serializer ASIC chip for the upgrade of the ATLAS muon detector

We report on the design of a serializer ASIC to be used in the ATLAS forward muon detector for trigger data transmission. We discuss the performance of a prototype chip covering power dissipation, latency and stable operating line rate. Tests show that the serializer is capable of running at least at 5.76 Gbps with a bit error ratio below 1x10^{-15}, and a power consumption of 200 mW running at 4.8 Gbps. The latency between the start of loading 30 bits into the serializer to the transmission of the first bit from the serializer is measured to be about 6 ns.

physics.ins-det

First results with a microcavity plasma panel detector

A new type of gaseous micropattern particle detector based on a closed-cell microcavity plasma panel sensor is reported. The first device was fabricated with 1 x 1 x 2 mm cells. It has shown very clean signals of 0.6 to 2.5 volt amplitude, fast rise time of approximately 2 ns and FWHM of about 2 ns with very uniform signal shapes across all pixels. From initial measurements with beta particles from a radioactive source, a maximum pixel efficiency of greater than 95% is calculated, for operation of the detector over a 100V wide span of high voltages (HV). Over this same HV range, the background rate per pixel was measured to be 3 to 4 orders of magnitude lower than the rate with the cell illuminated by the beta source. Pixel-to-pixel count rate uniformity is within 3% and stable within 3% for many days. The time resolution is 2.4 ns, and a very low cell-to-cell crosstalk has been measured between cells separated by 2 mm.

physics.ins-det

Development of a plasma panel radiation detector

This article reports on the development and experimental results of commercial plasma display panels adapted for their potential use as micropattern gas radiation detectors. The plasma panel sensors (PPS) design an materials include glass substrates, metal electrodes and inert gas mixtures which provide a physically robust, hermetically-sealed device. Plasma display panels used as detectors were tested with cosmic ray muons, beta rays and gamma rays, protons and thermal neutrons. The results demonstrated rise times and time resolution of a few nanoseconds, as well as sub-millimeter spatial resolution compatible with the pixel pitch.

physics.ins-det

Plasma panel-based radiation detectors

The plasma panel sensor (PPS) is a gaseous micropattern radiation detector under current development. It has many operational and fabrication principles common to plasma display panels. It comprises a dense matrix of small, gas plasma discharge cells within a hermetically sealed panel. As in plasma display panels, it uses nonreactive, intrinsically radiation-hard materials such as glass substrates, refractory metal electrodes, and mostly inert gas mixtures. We are developing these devices primarily as thin, low-mass detectors with gas gaps from a few hundred microns to a few millimeters. The PPS is a high gain, inherently digital device with the potential for fast response times, fine position resolution (<50-mm RMS) and low cost. In this paper, we report on prototype PPS experimental results in detecting betas, protons, and cosmic muons, and we extrapolate on the PPS potential for applications including the detection of alphas, heavy ions at low-to-medium energy, thermal neutrons, and X-rays.

physics.ins-det

Plasma Panel Sensors for Particle and Beam Detection

The plasma panel sensor (PPS) is an inherently digital, high gain, novel variant of micropattern gas detectors inspired by many operational and fabrication principles common to plasma display panels (PDPs). The PPS is comprised of a dense array of small, plasma discharge, gas cells within a hermetically-sealed glass panel, and is assembled from non-reactive, intrinsically radiation-hard materials such as glass substrates, metal electrodes and mostly inert gas mixtures. We are developing the technology to fabricate these devices with very low mass and small thickness, using gas gaps of at least a few hundred micrometers. Our tests with these devices demonstrate a spatial resolution of about 1 mm. We intend to make PPS devices with much smaller cells and the potential for much finer position resolutions. Our PPS tests also show response times of several nanoseconds. We report here our results in detecting betas, cosmic-ray muons, and our first proton beam tests.

physics.ins-det

Studies on fast triggering and high precision tracking with Resistive Plate Chambers

We report on studies of fast triggering and high-precision tracking using Resistive Plate Chambers (RPCs). Two beam tests were carried out with the 180 GeV muon beam at CERN using RPCs with gas gaps of 1.00 or 1.15 mm and equipped with readout strips with 1.27 mm pitch. This is the first beam test of RPCs with fine-pitch readout strips that explores simultaneously precision tracking and triggering capabilities. RPC signals were acquired with precision timing and charge integrating readout electronics at both ends of the strips. The time resolution was measured to be better than 600 ps and the average spatial resolution was found to be 220 um using charge information and 287 um using timing information. The dual-ended readout allows the determination of the average and the difference of the signal arrival times. The average time was found to be independent of the incident particle position along the strip and is useful for triggering purposes. The time difference yielded a determination of the hit position with a precision of 7.5 mm along the strip. These results demonstrate the feasibility using RPCs for fast and high-resolution triggering and tracking.

physics.ins-det

Development of a plasma panel radiation detector: recent progress and key issues

A radiation detector based on plasma display panel technology, which is the principal component of plasma television displays is presented. Plasma Panel Sensor (PPS) technology is a variant of micropattern gas radiation detectors. The PPS is conceived as an array of sealed plasma discharge gas cells which can be used for fast response (O(5ns) per pixel), high spatial resolution detection (pixel pitch can be less than 100 micrometer) of ionizing and minimum ionizing particles. The PPS is assembled from non-reactive, intrinsically radiation-hard materials: glass substrates, metal electrodes and inert gas mixtures. We report on the PPS development program, including simulations and design and the first laboratory studies which demonstrate the usage of plasma display panels in measurements of cosmic ray muons, as well as the expansion of experimental results on the detection of betas from radioactive sources.

physics.ins-det