SearcharxivSearch

arXiv subjects

J. W. Choi

Publications and source records attributed to J. W. Choi.

6 recordsLinked to original sources

First results from the search for an excess of $\barν_{e}$ events in JSNS$^2$

The JSNS$^2$ (J-PARC Sterile Neutrino Search at the J-PARC Spallation Neutron Source) experiment at the Material and Life Science Facility (MLF) of J-PARC is designed to directly test an excess on $\barν_{e}$ events which was indicated by LSND (Liquid Scintillator Neutrino Detector). The combination of a short-pulsed proton beam and a gadolinium-loaded liquid scintillator provides an excellent signal-to-noise ratio. In this article, we report the first results of a direct test based on data collected in 2022. After applying all event selection criteria, two events are observed, consistent with the expected background of 2.3$\pm$0.4 events. No excess of $\barν_e$ events are seen in this report, however the expected number of events due to LSND anomaly is 1.1$\pm$0.5, thus this result is not yet conclusive. Data taking has been ongoing since 2021 and will continue in future runs. In addition, a new far detector has recently been constructed for the second phase experiment, JSNS$^2$-II, marking an important milestone toward forthcoming measurements.

hep-ex

First Measurement of Missing Energy Due to Nuclear Effects in Monoenergetic Neutrino Charged Current Interactions

We present the first measurement of the missing energy due to nuclear effects in monoenergetic, muon neutrino charged-current interactions on carbon, originating from $K^+ \rightarrow μ^+ ν_μ$ decay at rest ($E_{ν_μ}=235.5$ MeV), performed with the J-PARC Sterile Neutrino Search at the J-PARC Spallation Neutron Source liquid scintillator based experiment. Toward characterizing the neutrino interaction, ostensibly $ν_μn \rightarrow μ^- p$ or $ν_μ$$^{12}\mathrm{C}$ $\rightarrow μ^-$$^{12}\mathrm{N}$, we define the missing energy as the energy transferred to the nucleus ($ω$) minus the kinetic energy of the outgoing proton(s), $E_{m} \equivω-\sum T_p$, and relate this to visible energy in the detector, $E_{m}=E_{ν_μ} (235.5 \mathrm{MeV})-m_μ(105.7 \mathrm{MeV}) + [m_n-m_p (1.3 \mathrm{MeV})] - E_{\mathrm{vis}}$. The missing energy, which is naively expected to be zero in the absence of nuclear effects (e.g. nucleon separation energy, Fermi momenta, and final-state interactions), is uniquely sensitive to many aspects of the interaction, and has previously been inaccessible with neutrinos. The shape-only, differential cross section measurement reported, based on a $(77\pm3)$% pure double-coincidence kaon decay-at-rest signal (621 total events), provides detailed insight into neutrino-nucleus interactions, allowing even the nuclear orbital shell of the struck nucleon to be inferred. The measurement provides an important benchmark for models and event generators at hundreds of MeV neutrino energies, characterized by the difficult-to-model transition region between neutrino-nucleus and neutrino-nucleon scattering, and relevant for applications in nuclear physics, neutrino oscillation measurements,and Type-II supernova studies.

hep-ex

The JSNS^2 Detector

The JSNS^2 (J-PARC Sterile Neutrino Search at J-PARC Spallation Neutron Source) experiment aims to search for oscillations involving a sterile neutrino in the eV^2 mass-splitting range. The experiment will search for the appearance of electron antineutrinos oscillated from muon antineutrinos. The electron antineutrinos are detected via the inverse beta decay process using a liquid scintillator detector. A 1MW beam of 3 GeV protons incident on a spallation neutron target produces an intense and pulsed neutrino source from pion, muon, and kaon decay at rest. The JSNS^2 detector is located 24 m away from the neutrino source and began operation from June 2020. The detector contains 17 tonnes of gadolinium (Gd) loaded liquid scintillator (LS) in an acrylic vessel, as a neutrino target. It is surrounded by 31 tonnes of unloaded LS in a stainless steel tank. Optical photons produced in LS are viewed by 120 R7081 Hamamatsu 10-inch Photomultiplier Tubes (PMTs). In this paper, we describe the JSNS^2 detector design, construction, and operation.

physics.ins-det

Slow control and monitoring system at the JSNS$^{2}$

The JSNS$^2$ experiment is aimed to search for sterile neutrino oscillations using a neutrino beam from muon decays at rest. The JSNS$^2$ detector contains 17 tons of 0.1\% gadolinium (Gd) loaded liquid scintillator (LS) as a neutrino target. Detector construction was completed in the spring of 2020. A slow control and monitoring system (SCMS) was implemented for reliable control and quick monitoring of the detector operational status and environmental conditions. It issues an alarm if any of the monitored parameters exceed a preset acceptable range. The SCMS monitors the high voltage (HV) of the photomultiplier tubes (PMTs), the LS level in the detector, possible LS overflow and leakage, the temperature and air pressure in the detector, the humidity of the experimental hall, and the LS flow rate during filling and extraction. An initial 10 days of data-taking with a neutrino beam was done following a successful commissioning of the detector and SCMS in June 2020. In this paper, we present a description of the assembly and installation of the SCMS and its performance.

physics.ins-det

Proposal: JSNS$^2$-II

This article describes the goal and expected sensitivity of the JSNS$^2$-II experiment at J-PARC Materials and Life Science Experimental Facility (MLF). The JSNS$^2$-II experiment is the second phase of the JSNS$^2$ experiment (J-PARC Sterile Neutrino Search at J-PARC Spallation Neutron Source) with two detectors which are located in 24 m (an existing detector) and 48 m (new one) baselines to improve the sensitivity of the search for sterile neutrinos, especially in the low $Δm^2$ region, which has been indicated by the global fit of the appearance mode. The new second detector has a similar structure as the existing JSNS$^2$ detector, which is already working. To compensate for the reduction of the neutrino flux due to the distance from the mercury target, the target mass of the Gd-loaded liquid scintillator which is the Linear AlkylBenzene (LAB) based liquid scintillator inside the acrylic vessel is 35 tons. To keep the same photo-coverage of the detector as the first detector, we will surround the acrylic vessel with 240 PMTs. With this experimental setup and 5 years (times 1 MW beam power) exposure, the sensitivity of the JSNS$^2$-II is significantly improved compared to the current JSNS$^2$, especially in the low $Δm^2$ oscillation parameter region. The JSNS$^2$-II can also confirm or refute the most of the oscillation parameters' space preferred by the previous experiments with 3 sigma C.L.. Considering these situations and world wide status of the sterile neutrino searches, we are eager to start the data taking with the two detector configuration from 2023. The fund to build the second detector was already secured.

hep-ex

Efficient Soft-Input Soft-Output Tree Detection Via an Improved Path Metric

Tree detection techniques are often used to reduce the complexity of a posteriori probability (APP) detection in high dimensional multi-antenna wireless communication systems. In this paper, we introduce an efficient soft-input soft-output tree detection algorithm that employs a new type of look-ahead path metric in the computation of its branch pruning (or sorting). While conventional path metrics depend only on symbols on a visited path, the new path metric accounts for unvisited parts of the tree in advance through an unconstrained linear estimator and adds a bias term that reflects the contribution of as-yet undecided symbols. By applying the linear estimate-based look-ahead path metric to an M-algorithm that selects the best M paths for each level of the tree we develop a new soft-input soft-output tree detector, called an improved soft-input soft-output M-algorithm (ISS-MA). Based on an analysis of the probability of correct path loss, we show that the improved path metric offers substantial performance gain over the conventional path metric. We also demonstrate through simulations that the ISS-MA provides a better performance-complexity trade-off than existing soft-input soft-output detection algorithms.

cs.IT