SearcharxivSearch

arXiv subjects

J. W. Ko

Publications and source records attributed to J. W. Ko.

4 recordsLinked to original sources

Search for $K_L \!\to\! π^0 ν\overlineν$ and $K_L \!\to\! π^0 X^0$ Decays at the J-PARC KOTO Experiment

A search for the rare decay $K_L \!\to\! π^0 ν\overlineν$ was performed. With the data collected in 2015, corresponding to $2.2 \times 10^{19}$ protons on target, a single event sensitivity of $( 1.30 \pm 0.01_{\rm stat} \pm 0.14_{\rm syst} ) \times 10^{-9}$ was achieved and no candidate events were observed. We set an upper limit of $3.0 \times 10^{-9}$ for the branching fraction of $K_L \!\to\! π^0 ν\overlineν$ at the 90% confidence level (C.L.), which improved the previous limit by almost an order of magnitude. An upper limit for $K_L \!\to\! π^0 X^0$ was also set as $2.4 \times 10^{-9}$ at the 90% C.L., where $X^0$ is an invisible boson with a mass of $135~{\rm MeV}/c^2$.

hep-ex

A new search for the $K_{L} \to π^0 ν\overlineν$ and $K_{L} \to π^{0} X^{0}$ decays

We searched for the $CP$-violating rare decay of neutral kaon, $K_{L} \to π^0 ν\overlineν$, in data from the first 100 hours of physics running in 2013 of the J-PARC KOTO experiment. One candidate event was observed while $0.34\pm0.16$ background events were expected. We set an upper limit of $5.1\times10^{-8}$ for the branching fraction at the 90\% confidence level (C.L.). An upper limit of $3.7\times10^{-8}$ at the 90\% C.L. for the $K_{L} \to π^{0} X^{0}$decay was also set for the first time, where $X^{0}$ is an invisible particle with a mass of 135 MeV/$c^{2}$.

hep-ex

Long-lived neutral-kaon flux measurement for the KOTO experiment

The KOTO ($K^0$ at Tokai) experiment aims to observe the CP-violating rare decay $K_L \rightarrow π^0 ν\barν$ by using a long-lived neutral-kaon beam produced by the 30 GeV proton beam at the Japan Proton Accelerator Research Complex. The $K_L$ flux is an essential parameter for the measurement of the branching fraction. Three $K_L$ neutral decay modes, $K_L \rightarrow 3π^0$, $K_L \rightarrow 2π^0$, and $K_L \rightarrow 2γ$ were used to measure the $K_L$ flux in the beam line in the 2013 KOTO engineering run. A Monte Carlo simulation was used to estimate the detector acceptance for these decays. Agreement was found between the simulation model and the experimental data, and the remaining systematic uncertainty was estimated at the 1.4\% level. The $K_L$ flux was measured as $(4.183 \pm 0.017_{\mathrm{stat.}} \pm 0.059_{\mathrm{sys.}}) \times 10^7$ $K_L$ per $2\times 10^{14}$ protons on a 66-mm-long Au target.

physics.ins-det

Source Counts at 15 microns from the AKARI NEP Survey

We present galaxy counts at 15 microns using the Japanese AKARI satellite's NEP-deep and NEP-wide legacy surveys at the North Ecliptic Pole. The total number of sources detected are approximately 6700 and 10,700 down to limiting fluxes of 117 and 250 microJy (5 sigma) for the NEP-deep and NEP-wide survey respectively. We construct the Euclidean normalized differential source counts for both data sets (assuming 80 percent completeness levels of 200 and 270 microJy respectively) to produce the widest and deepest contiguous survey at 15 microns to date covering the entire flux range from the deepest to shallowest surveys made with the Infrared Space Observatory (ISO) over areas sufficiently significant to overcome cosmic variance, detecting six times as many sources as the largest survey carried out with ISO.We compare the results from AKARI with the previous surveys with ISO at the same wavelength and the Spitzer observations at 16 microns using the peek-up camera on its IRS instrument. The AKARI source counts are consistent with other results to date reproducing the steep evolutionary rise at fluxes less than a milliJansky and super-Euclidean slopes. We find the the AKARI source counts show a slight excess at fluxes fainter than 200 microJanskys which is not predicted by previous source count models at 15 microns. However, we caution that at this level we may be suffering from the effects of source confusion in our data. At brighter fluxes greater than a milliJansky, the NEP-wide survey source counts agree with the Northern ISO-ELAIS field results, resolving the discrepancy of the bright end calibration in the ISO 15 micron source counts.

astro-ph.CO