Inverter Output Impedance Estimation in Power Networks: A Variable Direction Forgetting Recursive-Least-Square Algorithm Based Approach

As inverter-based loads and energy sources become increasingly prevalent, accurate estimation of line impedance between inverters and the grid is essential for optimizing performance and enhancing control strategies. This paper presents a non-invasive method for estimating output-line impedance using measurements local to the inverter. It provides a specific method for signal conditioning of signals measured at the inverter, which makes the measured data better suited to estimation algorithms. An algorithm based on the Variable Direction Forgetting Recursive Least Squares (VDF-RLS) method is introduced, which leverages these conditioned signals for precise impedance estimation. The signal conditioning process transforms measurements into the direct-quadrature (dq) coordinate frame, where the rotating frame frequency is determined to facilitate a simpler and more accurate estimation. This frequency is implemented using a secondary Phase-Locked Loop (PLL) to attenuate grid voltage measurement variations. By isolating the variation-sensitive q-axis and relying solely on the less sensitive d-axis, the method further minimizes the impact of variations. The VDF-RLS estimation method achieves rapid adaptation while ensuring stability in the absence of persistent excitation by selectively discarding outdated data during updates. Proposed conditioning and estimation methods are non-invasive; estimations are solely done using measured outputs, and no signal is injected into the power network. Simulation results demonstrate a significant improvement in impedance estimation stability, particularly in low-excitation conditions, where the VDF-RLS method achieves more than three time lower error compared to existing approaches such as constant forgetting RLS and the Kalman filter.

eess.SY

Multi-Mode Inverters: A Unified Control Design for Grid-Forming, Grid-Following, and Beyond

We present a novel, integrated control framework designed to achieve seamless transitions among a spectrum of inverter operation modes. The operation spectrum includes grid-forming (GFM), grid-following (GFL), static synchronous compensator (STATCOM), energy storage system (ESS), and voltage source inverter (VSI). The proposed control architecture offers guarantees of stability, robustness, and performance regardless of the specific mode. The core concept involves establishing a unified algebraic structure for the feedback control system, where different modes are defined by the magnitude of closed-loop signals. As we demonstrate, this approach results in a two-dimensional continuum of operation modes and enables transition trajectories between operation modes by dynamically adjusting closed-loop variables towards corresponding setpoints. Stability, robustness, and fundamental limitation analyses are provided for the closed-loop system across any mode, as well as during transitions between modes. This design facilitates stable and enhanced on-grid integration, even during GFM operation and weak grid conditions. Ultimately, we demonstrate the key attributes of the proposed framework through simulations and experiments, showcasing its seamless transition in on-grid operation, functionality in islanded mode, and robustness to line impedance uncertainty.

eess.SY

Control Designs for Critical-Continegency Responsible Grid-Following Inverters and Seamless Transitions To and From Grid-Forming Modes

This article introduces two control frameworks: one for Grid-Following (GFL) inverters aiding Grid-Forming (GFM) inverters in voltage regulation during large contingency events and optimizing power transactions under normal conditions; and another for seamless transitions between grid-tied and grid-isolated setups, managing voltage transient characteristics. In microgrids, GFM inverters regulate voltage, while GFL inverters handle power transactions. The proposed GFL control detects abrupt load/generation changes, adjusting power transactions using local storage to support GFM inverters during contingencies. Additionally, a transition control ensures smooth GFL-GFM shifts, reducing power and voltage fluctuations. Simulation results validate improved voltage regulation during contingencies and enhanced power tracking during slow changes, alongside minimized transient overshoot.

eess.SY

Enhanced Grid Following Inverter (E-GFL): A Unified Control Framework for Stiff and Weak Grids

This paper presents an extensive framework focused on the control design, along with stability and performance analysis, of Grid-Following Inverters (GFL). It aims to ensure their effective operation under both stiff and weak grid conditions. The proposed framework leverages the coupled algebraic structure of the transmission line dynamics in the $dq$ frame to express and then mitigate the effect of coupled dynamics on the GFL inverter's stability and performance. Additionally, we simplify the coupled multi-input, multi-output (MIMO) closed-loop system of the GFL into two separate single-input, single-output (2-SISO) closed-loops for easier analysis and control design. We present the stability, robust stability, and performance of the original GFL MIMO closed-loop system through our proposed 2-SISO closed-loop framework. This approach simplifies both the control design and its analysis. Our framework effectively achieves grid synchronization and active damping of filter resonance via feedback control. This eliminates the need for separate phase-locked loop (PLL) and virtual impedance subsystems. We also utilize the Bode sensitivity integral to define the limits of GFL closed-loop stability margin and performance. These fundamental limits reveal the necessary trade-offs between various performance goals, including reference tracking, closed-loop bandwidth, robust synchronization, and the ability to withstand grid disturbances. Finally, we demonstrate the merits of our proposed framework through detailed simulations and experiments. These showcase its effectiveness in handling challenging scenarios, such as asymmetric grid faults, low voltage operation, and the balance between harmonic rejection and resonance suppression.

eess.SY

Control Design for Inverters: Beyond Steady-State Droop Laws

This paper presents a novel control structure and control synthesis method for regulating the output voltage/frequency and power injection of DC-AC inverters. The traditional droop method offers attractive solution to achieve compromise between clashing power and voltage/frequency regulation objectives. However, it relies on use of nonlinear power variables through slow outer control loop. In this paper we formulate the traditional droop method as a feedback control problem based on static power-flow equations and show how neglecting the dynamics of inverter and transmission line restricts the attainable closed-loop bandwidth and stability and robustness margin. Then we introduce a mapping between power variables and current in $dq$ frame under given PLL condition, allowing for replacing the fast acting current variables as a proxy for power. Consequently, we present a novel control structure and control synthesis method based on disturbance rejection framework, and demonstrate inherent droop like characteristics in underlying dynamics for special cases of resistive and inductive line. Moreover, we generalize the proposed control synthesis procedure to include a generalized complex line dynamical model and introduce concept of hybrid-sourced-intverter. Finally, we validate higher bandwidth and better transient performance of our proposed design through experimental validation.