SearcharxivSearch

arXiv subjects

Jake Barralet

Publications and source records attributed to Jake Barralet.

2 recordsLinked to original sources

Neural Minimum-Distance Estimation for Collision-Aware Operation of Multi-Arm Laparoscopy Surgical Robots Through Learning-from-Simulation

This study presents an integrated framework for enhancing the safety and operational efficiency of robotic arms in laparoscopic surgery by addressing minimum distance estimation between multi-arm manipulators and the associated collision-aware warning. By combining analytical modeling, real time simulation, and machine learning, the framework offers a robust solution for ensuring safe robotic operations. An analytical model was developed to estimate the minimum distances between robotic arms based on their joint configurations, offering theoretical calculations that serve as both a validation tool and a benchmark. To complement this, a 3D simulation environment was created to model two 7 DOF Kinova robotic arms (Kinova inc., Boisbriand, QC, Canada), generating a diverse dataset of configurations for distance estimation and collision warning. Using these insights, a deep residual neural network model was trained with joint configurations as inputs. On the held out validation set, the model achieves R2 = 0.940, RMSE = 42.0 mm, MAE = 28.7 mm, and a near zero mean bias, demonstrating strong predictive accuracy and consistent generalization across the workspace. The framework is intended as an early collision warning layer, where a warning is triggered when the predicted inter-arm distance falls below a 0.2 m threshold, which corresponds to a surface to surface clearance of approximately 50 mm given the Kinova Gen3 (Kinova inc., Boisbriand, QC, Canada) cross sectional radius. This work demonstrates the effectiveness of combining analytical modeling with machine learning to enhance the precision and reliability of multi-arm robotic systems.

cs.RO

Learning-based Force Sensing and Impedance Matching for Safe Haptic Feedback in Robot-assisted Laparoscopic Surgery

Integrating accurate haptic feedback into robot-assisted minimally invasive surgery (RAMIS) remains challenging due to difficulties in precise force rendering and ensuring system safety during teleoperation. We present a Nonlinear Impedance Matching Approach (NIMA) that extends our previously validated Impedance Matching Approach (IMA) by incorporating nonlinear dynamics to accurately model and render complex tool-tissue interactions in real-time. NIMA achieves a mean absolute error of 0.01 (std 0.02 N), representing a 95% reduction compared to IMA. Additionally, NIMA eliminates haptic "kickback" by ensuring zero force is applied to the user's hand when they release the handle, enhancing both patient safety and operator comfort. By accounting for nonlinearities in tool-tissue interactions, NIMA significantly improves force fidelity, responsiveness, and precision across various surgical conditions, advancing haptic feedback systems for reliable robot-assisted surgical procedures.

cs.RO