Searcharxiv⌕ Search

arXiv subjects

James B. R. Battat

Publications and source records attributed to James B. R. Battat.

14 recordsLinked to original sources

Liquid argon purification and purity monitoring: apparatus and first results

We report results from a 13-liter purified liquid argon test stand at Wellesley College in Massachusetts, USA. The system includes a single-pass liquid-phase purification column that can achieve sub-part-per-billion impurity levels. The liquid argon purity is measured with a double-gridded purity monitor to assess the electron lifetime. Measurements demonstrate an O2-equivalent impurity concentration of $0.21 \pm 0.05$ ppb (stable over a 20-hour duration), corresponding to an electron lifetime of 1.6 ms at a drift field of 500 V/cm. This test stand supports ongoing detector R\&D on charge and light readout for liquid argon time projection chambers, such as Q-Pix and other cold electronics systems.

physics.ins-det↗

First operation of a multi-channel Q-Pix prototype: measuring transverse electron diffusion in a gas time projection chamber

We report measurements of the transverse diffusion of electrons in P-10 gas (90% Ar, 10% CH4) in a laboratory-scale time projection chamber (TPC) utilizing a novel pixelated signal capture and digitization technique known as Q-Pix. The Q-Pix method incorporates a precision switched integrating transimpedance amplifier whose output is compared to a threshold voltage. Upon reaching the threshold, a comparator sends a 'reset' signal, initiating a discharge of the integrating capacitor. The time difference between successive resets is inversely proportional to the average current at the pixel in that time interval, and the number of resets is directly proportional to the total collected charge. We developed a 16-channel Q-Pix prototype fabricated from commercial off-the-shelf components and coupled them to 16 concentric annular anode electrodes to measure the spatial extent of the electron swarm that reaches the anode after drifting through the uniform field of the TPC. The swarm is produced at a gold photocathode using pulsed UV light. The measured transverse diffusion agrees with simulations in PyBoltz across a range of operating pressures (200-1500 Torr). These results demonstrate that a Q-Pix readout can successfully reconstruct the ionization topology in a TPC.

hep-ex↗

A clear case for dust obscuration of the lunar retroreflectors

The passive retroreflector arrays placed on the moon by Apollo 11, 14 and 15 astronauts continue to produce valuable Earth-Moon range measurements that enable high-precision tests of gravitational physics, as well as studies of geo- and selenophysics. The optical throughput of these retroreflectors has declined since their deployment, with an additional signal loss at full moon when the reflectors experience direct solar illumination. We show that the loss in return rate can be attributed to the accumulation of a thin layer of lunar dust on the surfaces of the corner cube retroreflectors. First, a careful analysis of the optical link budget for the Apache Point Observatory Lunar Laser-ranging Operation (APOLLO) experiment reveals that the lunar return rate is 15--20 times smaller than predicted, a deficit that can be explained by a reflector dust covering fraction of ${\sim} 50$\%. Second, range measurements taken during a lunar eclipse indicate that the solar illumination of the retroreflectors degrades their throughput by an additional factor of ${\sim}15$. Finally, a numerical simulation of heat transfer in dust-coated reflectors is able to model the resulting thermal lensing effect, in which thermal gradients in the retroreflectors degrade their far-field diffraction pattern. A comparison of this simulation to eclipse measurements finds a dust coverage fraction of ${\sim}50$%. Taken together, the link analysis, eclipse observations and thermal modeling support the claim that the retroreflectors are obscured by lunar dust, with both link budget and simulation independently finding the dust fraction to be $\sim$50%.

astro-ph.IM↗

The Role of Low-energy (< 20 eV) Secondary Electrons in the Extraterrestrial Synthesis of Prebiotic Molecules

We demonstrate for the first time that Galactic cosmic rays with energies as high as 1e10 eV can trigger a cascade of low-energy (< 20 eV) secondary electrons that could be a significant contributor to the interstellar synthesis of prebiotic molecules whose delivery by comets, meteorites, and interplanetary dust particles may have kick-started life on Earth. We explore the relative importance of low-energy (< 20 eV) secondary electrons--agents of radiation chemistry--and low-energy (< 10 eV), non-ionizing photons--instigators of photochemistry. Our calculations indicate fluxes of 100 electrons/cm2/s for low-energy secondary electrons produced within interstellar ices due to incident attenuated Galactic cosmic-ray (CR) protons. Consequently, in certain star-forming regions where internal high-energy radiation sources produce ionization rates that are observed to be a thousand times greater than the typical interstellar Galactic ionization rate, the flux of low-energy secondary electrons should far exceed that of non-ionizing photons. Because reaction cross-sections can be several orders of magnitude larger for electrons than for photons, even in the absence of such enhancement our calculations indicate that secondary low-energy electrons are at least as significant as low-energy (< 10 eV) non-ionizing photons in the interstellar synthesis of prebiotic molecules. Most importantly, our results demonstrate the pressing need for explicitly incorporating low-energy electrons in current and future astrochemical simulations of cosmic ices. Such models are critically important for interpreting James Webb Space Telescope infrared measurements, which are currently being used to probe the origins of life by studying complex organic molecules found in ices near star-forming regions.

astro-ph.HE↗

Demonstrating the Q-Pix front-end using discrete OpAmp and CMOS transistors

Using Commercial Off-The-Shelf (COTS) Operational Amplifiers (OpAmps) and Complementary Metal-Oxide Semiconductor (CMOS) transistors, we present a demonstration of the Q-Pix front-end architecture, a novel readout solution for kiloton-scale Liquid Argon Time Projection Chamber (LArTPC) detectors. The Q-Pix scheme employs a Charge-Integrate/Reset process based on the Least Action principle, enabling pixel-scale self-triggering charge collection and processing, minimizing energy consumption, and maximizing data compression. We examine the architecture's sensitivity, linearity, noise, and other features at the circuit board level and draw comparisons to SPICE simulations. Furthermore, we highlight the resemblance between the Q-Pix front-end and Sigma-Delta modulator, emphasizing that digital data processing techniques for Sigma-Delta can be directly applied to Q-Pix, resulting in enhanced signal-to-noise performance. These insights will inform the development of Q-Pix front-end designs in integrated circuits (IC) and guide data collection and processing for future large-scale LArTPC detectors in neutrino physics and other high-energy physics experiments.

physics.ins-det↗

Fifteen years of millimeter accuracy lunar laser ranging with APOLLO: dataset characterization

We present data from the Apache Point Observatory Lunar Laser-ranging Operation (APOLLO) covering the 15-year span from April 2006 through the end of 2020. APOLLO measures the earth-moon separation by recording the round-trip travel time of photons from the Apache Point Observatory to five retro-reflector arrays on the moon. The APOLLO data set, combined with the 50-year archive of measurements from other lunar laser ranging (LLR) stations, can be used to probe fundamental physics such as gravity and Lorentz symmetry, as well as properties of the moon itself. We show that range measurements performed by APOLLO since 2006 have a median nightly accuracy of 1.7 mm, which is significantly better than other LLR stations.

astro-ph.IM↗

Fifteen years of millimeter accuracy lunar laser ranging with APOLLO: data reduction and calibration

The Apache Point Lunar Laser-ranging Operation (APOLLO) has been collecting lunar range measurements for 15 years at millimeter accuracy. The median nightly range uncertainty since 2006 is 1.7 mm. A recently added Absolute Calibration System (ACS), providing an independent assessment of APOLLO system accuracy and the capability to correct lunar range data, revealed a 0.4% systematic error in the calibration of one piece of hardware that has been present for the entire history of APOLLO. Application of ACS-based timing corrections suggests systematic errors are reduced to < 1 mm, such that overall data accuracy and precision are both 1 mm. This paper describes the processing of APOLLO/ACS data that converts photon-by-photon range measurements into the aggregated normal points that are used for physics analyses. Additionally we present methodologies to estimate timing corrections for range data lacking contemporaneous ACS photons, including range data collected prior to installation of the ACS. We also provide access to the full 15-year archive of APOLLO normal points (2006-04-06 to 2020-12-27).

astro-ph.IM↗

The Planetary Ephemeris Program: Capability, Comparison, and Open Source Availability

We describe for the first time in the scientific literature the Planetary Ephemeris Program (PEP), an open-source general-purpose astrometric data analysis program. We discuss, in particular, the implementation of pulsar timing analysis, which was recently upgraded in PEP to handle more options. This implementation was done independently of other pulsar programs, with minor exceptions that we discuss. We illustrate the implementation of this capability by comparing the post-fit residuals from the analyses of time-of-arrival observations by both PEP and Tempo2. The comparison shows substantial agreement: 22 ns rms differences for 1,065 pulse time-of-arrival measurements for the millisecond pulsar in a binary system, PSR J1909-3744 (pulse period 2.947108 ms; full-width half-maximum of pulse 43 $μ$s) for epochs in the interval from December 2002 to February 2011.

astro-ph.IM↗

Prototype Analog Front-end for Negative-ion Gas and Dual-phase Liquid-Ar TPCs

We report on the recent development of a versatile analog front-end compatible with a negative-ion $μ$-TPC for a directional dark matter search as well as a dual-phase, next-generation $\mathcal{O}$(10~kt) liquid argon TPC to study neutrino oscillations, nucleon decay, and astrophysical neutrinos. Although the operating conditions for negative-ion and liquid argon TPCs are quite different (room temperature \textit{vs.} $\sim$88~K operation, respectively), the readout electronics requirements are similar. Both require a wide-dynamic range up to 1600 fC, and less than 2000--5000 e$^-$ noise for a typical signal of 80 fC with a detector capacitance of $C_{\rm det} \approx 300$~pF. In order to fulfill such challenging requirements, a prototype ASIC was newly designed using 180-nm CMOS technology. Here, we report on the performance of this ASIC, including measurements of shaping time, dynamic range, and equivalent noise charge (ENC). We also demonstrate the first operation of this ASIC on a low-pressure negative-ion $μ$-TPC.

physics.ins-det↗

Reducing DRIFT Backgrounds with a Submicron Aluminized-Mylar Cathode

Background events in the DRIFT-IId dark matter detector, mimicking potential WIMP signals, are predominantly caused by alpha decays on the central cathode in which the alpha particle is completely or partially absorbed by the cathode material. We installed a 0.9 micron thick aluminized-mylar cathode as a way to reduce the probability of producing these backgrounds. We study three generations of cathode (wire, thin-film, and radiologically clean thin-film) with a focus on the ratio of background events to alpha decays. Two independent methods of measuring the absolute alpha decay rate are used to ensure an accurate result, and agree to within $10\%$. Using alpha range spectroscopy, we measure the radiologically cleanest cathode version to have a contamination of $3.3\pm0.1$ ppt $^{234}$U and $73\pm2$ ppb $^{238}$U. This cathode reduces the probability of producing an RPR from an alpha decay by a factor of $70\pm20$ compared to the original stainless steel wire cathode. First results are presented from a texturized version of the cathode, intended to be even more transparent to alpha particles. These efforts, along with other background reduction measures, have resulted in a drop in the observed background rate from 500/day to 1/day. With the recent implementation of full-volume fiducialization, these remaining background events are identified, allowing for background-free operation.

physics.ins-det↗

Understanding Current Signals Induced by Drifting Electrons

Consider an electron drifting in a gas toward a collection electrode. A common misconception is that the electron produces a detectable signal only upon arrival at the electrode. In fact, the situation is quite the opposite. The electron induces a detectable current in the electrode as soon as it starts moving through the gas. This induced current vanishes when the electron arrives at the plate. To illustrate this phenomenon experimentally, we use a gas-filled parallel plate ionization chamber and a collimated $^{241}$Am alpha source, which produces a track of a fixed number of ionization electrons at a constant distance from the collection electrode. We find that the detected signal from the ionization chamber grows with the electron drift distance, as predicted by the model of charge induction, and in conflict with the idea that electrons are detectable upon arrival at the collection plate.

physics.ins-det↗

Solar system constraints on the Dvali-Gabadadze-Porrati braneworld theory of gravity

A number of proposals have been put forward to account for the observed accelerating expansion of the Universe through modifications of gravity. One specific scenario, Dvali-Gabadadze-Porrati (DGP) gravity, gives rise to a potentially observable anomaly in the solar system: all planets would exhibit a common anomalous precession, dw/dt, in excess of the prediction of General Relativity. We have used the Planetary Ephemeris Program (PEP) along with planetary radar and radio tracking data to set a constraint of |dw/dt| < 0.02 arcseconds per century on the presence of any such common precession. This sensitivity falls short of that needed to detect the estimated universal precession of |dw/dt| = 5e-4 arcseconds per century expected in the DGP scenario. We discuss the fact that ranging data between objects that orbit in a common plane cannot constrain the DGP scenario. It is only through the relative inclinations of the planetary orbital planes that solar system ranging data have sensitivity to the DGP-like effect of universal precession. In addition, we illustrate the importance of performing a numerical evaluation of the sensitivity of the data set and model to any perturbative precession.

gr-qc↗

Testing for Lorentz Violation: Constraints on Standard-Model Extension Parameters via Lunar Laser Ranging

We present constraints on violations of Lorentz Invariance based on Lunar Laser Ranging (LLR) data. LLR measures the Earth-Moon separation by timing the round-trip travel of light between the two bodies, and is currently accurate to a few centimeters (parts in $10^{11}$ of the total distance). By analyzing archival LLR data under the Standard-Model Extension (SME) framework, we derived six observational constraints on dimensionless SME parameters that describe potential Lorentz-violation. We found no evidence for Lorentz violation at the $10^{-6}$ to $10^{-11}$ level in these parameters.

gr-qc↗

The First Lunar Ranging Constraints on Gravity Sector SME Parameters

We present the first constraints on pure-gravity sector Standard-Model Extension (SME) parameters using Lunar Laser Ranging (LLR). LLR measures the round trip travel time of light between the Earth and the Moon. With 34+ years of LLR data, we have constrained six independent linear combinations of SME parameters at the level of $10^{-6}$ to $10^{-11}$. There is no evidence for Lorentz violation in the LLR dataset.

gr-qc↗