Searcharxiv⌕ Search

arXiv subjects

James Hays-Wehle

Publications and source records attributed to James Hays-Wehle.

6 recordsLinked to original sources

Optimization of an Optical Testbed for Characterization of EXCLAIM u-Spec Integrated Spectrometers

We describe a testbed to characterize the optical response of compact superconducting on-chip spectrometers in development for the Experiment for Cryogenic Large-Aperture Intensity Mapping (EXCLAIM) mission. EXCLAIM is a balloonborne far-infrared experiment to probe the CO and CII emission lines in galaxies from redshift 3.5 to the present. The spectrometer, called u-Spec, comprises a diffraction grating on a silicon chip coupled to kinetic inductance detectors (KIDs) read out via a single microwave feedline. We use a prototype spectrometer for EXCLAIM to demonstrate our ability to characterize the spectrometers spectral response using a photomixer source. We utilize an on-chip reference detector to normalize relative to spectral structure from the off-chip optics and a silicon etalon to calibrate the absolute frequency.

astro-ph.IM↗

Optical Characterization & Testbed Development for μ-Spec Integrated Spectrometers

This paper describes a cryogenic optical testbed developed to characterize u-Spec spectrometers in a dedicated dilution refrigerator (DR) system. u-Spec is a far-infrared integrated spectrometer that is an analog to a Rowland-type grating spectrometer. It employs a single-crystal silicon substrate with niobium microstrip lines and aluminum kinetic inductance detectors (KIDs). Current designs with a resolution of 512 are in fabrication for the EXCLAIM (Experiment for Cryogenic Large Aperture Intensity Mapping) balloon mission. The primary spectrometer performance and design parameters are efficiency, NEP, inter-channel isolation, spectral resolution, and frequency response for each channel. Here we present the development and design of an optical characterization facility and preliminary validation of that facility with earlier prototype R=64 devices. We have conducted and describe initial optical measurements of R = 64 devices using a swept photomixer line source. We also discuss the test plan for optical characterization of the EXCLAIM R = 512 u-Spec devices in this new testbed.

astro-ph.IM↗

Overview and status of EXCLAIM, the experiment for cryogenic large-aperture intensity mapping

The EXperiment for Cryogenic Large-Aperture Intensity Mapping (EXCLAIM) is a balloon-borne far-infrared telescope that will survey star formation history over cosmological time scales to improve our understanding of why the star formation rate declined at redshift z < 2, despite continued clustering of dark matter. Specifically,EXCLAIM will map the emission of redshifted carbon monoxide and singly-ionized carbon lines in windows over a redshift range 0 < z < 3.5, following an innovative approach known as intensity mapping. Intensity mapping measures the statistics of brightness fluctuations of cumulative line emissions instead of detecting individual galaxies, thus enabling a blind, complete census of the emitting gas. To detect this emission unambiguously, EXCLAIM will cross-correlate with a spectroscopic galaxy catalog. The EXCLAIM mission uses a cryogenic design to cool the telescope optics to approximately 1.7 K. The telescope features a 90-cm primary mirror to probe spatial scales on the sky from the linear regime up to shot noise-dominated scales. The telescope optical elements couple to six μ-Spec spectrometer modules, operating over a 420-540 GHz frequency band with a spectral resolution of 512 and featuring microwave kinetic inductance detectors. A Radio Frequency System-on-Chip (RFSoC) reads out the detectors in the baseline design. The cryogenic telescope and the sensitive detectors allow EXCLAIM to reach high sensitivity in spectral windows of low emission in the upper atmosphere. Here, an overview of the mission design and development status since the start of the EXCLAIM project in early 2019 is presented.

astro-ph.IM↗

SOFIA - HIRMES: Looking forward to the HIgh-Resolution Mid-infrarEd Spectrometer

The HIgh-Resolution Mid-infrarEd Spectrometer (HIRMES) is the 3rd Generation Instrument for the Stratospheric Observatory For Infrared Astronomy (SOFIA), currently in development at the NASA Goddard Space Flight Center (GSFC), and due for commissioning in 2019. By combining direct-detection Transition Edge Sensor (TES) bolometer arrays, grating-dispersive spectroscopy, and a host of Fabry-Perot tunable filters, HIRMES will provide the ability for High Resolution (R~100,000), Mid-Resolution (R~10,000), and Low-Resolution (R~600) slit-spectroscopy, and 2D Spectral Imaging (R~2000 at selected wavelengths) over the 25 - 122 μm mid-far infrared waveband. The driving science application is the evolution of proto-planetary systems via measurements of water-vapor, water-ice, deuterated hydrogen (HD), and neutral oxygen lines. However, HIRMES has been designed to be as flexible as possible to cover a wide range of science cases that fall within its phase-space, all whilst reaching sensitivities and observing powers not yet seen thus far on SOFIA, providing unique observing capabilities which will remain unmatched for decades.

astro-ph.IM↗

Microstructure analysis of bismuth absorbers for transition-edge sensor X-ray microcalorimeters

Transition-edge sensors (TESs) as microcalorimeters offer high resolving power, owning to their sharp response and low operating temperature. In the hard X-ray regime and above, the demand for high quantum-efficiency requires the use of absorbers. Bismuth (Bi), owing to its low heat carrier density and high X-ray stopping power, has been widely used as an absorber material for TESs. However, distinct spectral responses have been observed for Bi absorbers deposited via evaporation versus electroplating. Evaporated Bi absorbers are widely observed to have a non-Gaussian tail on the low energy side of measured spectra. In this study, we fabricated Bi absorbers via these two methods, and performed microstructure analysis using scanning electron microscopy (SEM) and X-ray diffraction microscopy. The two types of material showed the same crystallographic structure, but the grain size of the evaporated Bi was about 40 times smaller than that of the electroplated Bi. This distinction in grain size is likely to be the cause of their different spectral responses.

physics.ins-det↗

Eliminating the non-Gaussian spectral response of X-ray absorbers for transition-edge sensors

Transition-edge sensors (TES) as microcalorimeters for high-energy-resolution X-ray spectroscopy are often fabricated with an absorber made of materials with high Z (for X-ray stopping power) and low heat capacity (for high resolving power). Bismuth represents one of the most compelling options. TESs with evaporated bismuth absorbers have shown spectra with undesirable and unexplained low-energy tails. We have developed TESs with electroplated bismuth absorbers over a gold layer that are not afflicted by this problem and that retain the other positive aspects of this material. To better understand these phenomena, we have studied a series of TESs with gold, gold/evaporated bismuth, and gold/electroplated bismuth absorbers, fabricated on the same die with identical thermal coupling. We show that bismuth morphology is linked to the spectral response of X-ray TES microcalorimeters.

physics.ins-det↗