SearcharxivSearch

arXiv subjects

James J. Lah

Publications and source records attributed to James J. Lah.

7 recordsLinked to original sources

XAI-Refine: An Automated Explanation-Knowledge Loop for Brain-Age Prediction

Brain-age prediction models are commonly evaluated by predictive accuracy, yet accurate predictions alone do not establish that a model relies on reproducible or neurobiologically supported mechanisms. Post-hoc explanation methods can expose these mechanisms, but existing workflows typically stop at diagnosis or require correction targets to be specified before model analysis. We propose XAI-Refine, an automated explanation-knowledge loop for brain-age prediction from resting-state functional connectivity. At each iteration, XAI-Refine consolidates complementary post-hoc analyses across repeated training runs into reliable, structured model explanations. It converts each reliable explanation into a neutral neurobiological question, retrieves and verifies relevant literature, and compiles the verified evidence into an admissible set in the same typed explanation space. The target for refinement is defined as the minimal projection of the current model explanation onto the admissible set induced by applicable verified knowledge. This revised explanation is then translated into a differentiable constraint while preserving the originating model variable, measurement operator, and applicable scope. Candidate updates are promoted only when multi-seed validation confirms target-directed explanatory movement, predictive performance remains within a prespecified guardrail, and non-target explanatory drift remains bounded. Experiments on functional-connectivity-based brain-age prediction evaluate predictive performance, explanation reliability, literature alignment, and target-specific model revision, illustrating a structured route from post-hoc analysis to evidence-guided model refinement.

cs.LG

Laplace-Mixture Dipole Inversion for Quantitative Susceptibility Mapping

Purpose: To develop an automatic dipole inversion method for quantitative susceptibility mapping (QSM) that preserves fine anatomical structures without the need for manual regularization-parameter tuning. Theory: The original approximate message passing with parameter estimation (AMP-PE) framework models image gradients with a single Laplace prior, which does not fully capture the heavy-tailed gradient distribution of brain susceptibility maps. This prior mismatch can lead to over-regularization and blocky reconstructions. We address this limitation by modeling the gradients with a two-component Laplace mixture prior. Methods: We propose a Laplace-Mixture Dipole Inversion (LAMDI) method by incorporating a two-component Laplace mixture prior into the AMP-PE framework with automatic parameter estimation. LAMDI was evaluated on a public in vivo dataset. Its performance was compared with FANSI, MEDI, and AMP-PE with a single-Laplace prior (AMP-PE-L1) under both standard default and reference-tuned settings. Results: On a public multi-orientation QSM dataset, LAMDI achieved NRMSE and SSIM comparable to AMP-PE-L1 while substantially reducing HFEN, suggesting improved preservation of high-frequency anatomical detail. Under reference-based tuning, FANSI and MEDI achieved the best performance for some metrics, but LAMDI remained competitive without requiring reference maps or manual regularization tuning. Conclusion: LAMDI provides an effective and automatic parameter-estimation alternative for QSM dipole inversion by combining competitive reconstruction accuracy with improved preservation of fine anatomical detail.

eess.IV

Atlas-free Brain Network Transformer

Current atlas-based approaches to brain network analysis rely heavily on standardized anatomical or connectivity-driven brain atlases. However, these fixed atlases often introduce significant limitations, such as spatial misalignment across individuals, functional heterogeneity within predefined regions, and atlas-selection biases, collectively undermining the reliability and interpretability of the derived brain networks. To address these challenges, we propose a novel atlas-free brain network transformer (atlas-free BNT) that leverages individualized brain parcellations derived directly from subject-specific resting-state fMRI data. Our approach computes ROI-to-voxel connectivity features in a standardized voxel-based feature space, which are subsequently processed using the BNT architecture to produce comparable subject-level embeddings. Experimental evaluations on sex classification and brain-connectome age prediction tasks demonstrate that our atlas-free BNT consistently outperforms state-of-the-art atlas-based methods, including elastic net, BrainGNN, Graphormer and the original BNT. Our atlas-free approach significantly improves the precision, robustness, and generalizability of brain network analyses. This advancement holds great potential to enhance neuroimaging biomarkers and clinical diagnostic tools for personalized precision medicine. Reproducible code is available at https://github.com/shuai-huang/atlas_free_bnt

q-bio.NC

Model-based T1, T2* and Proton Density Mapping Using a Bayesian Approach with Parameter Estimation and Complementary Undersampling Patterns

Purpose: To achieve automatic hyperparameter estimation for the joint recovery of quantitative MR images, we propose a Bayesian formulation of the reconstruction problem that incorporates the signal model. Additionally, we investigate the use of complementary undersampling patterns to determine optimal undersampling schemes for quantitative MRI. Theory: We introduce a novel nonlinear approximate message passing framework, referred to as ``AMP-PE'', that enables the simultaneous recovery of distribution parameters and quantitative maps. Methods: We employed the variable flip angle multi-echo (VFA-ME) method to acquire measurements. Both retrospective and prospective undersampling approaches were utilized to obtain Fourier measurements using variable-density and Poisson-disk patterns. Furthermore, we extensively explored various undersampling schemes, incorporating complementary patterns across different flip angles and/or echo times. Results: AMP-PE adopts a model-based joint recovery strategy, it outperforms the $l_1$-norm minimization approach that follows a decoupled recovery strategy. A comparison with an existing joint-recovery approach further demonstrates the advantageous outcomes of AMP-PE. For quantitative $T_1$ mapping using VFA-ME, employing identical k-space sampling patterns across different echo times produced the best performance. Whereas for $T_2^*$ and proton density mappings, using complementary sampling patterns across different flip angles yielded the best performance. Conclusion: AMP-PE is equipped with built-in parameter estimation, and works naturally in clinical settings with varying acquisition protocols and scanners. It also achieves improved performance by combining information from the MR signal model and the sparse prior on images.

eess.IV

Robust Quantitative Susceptibility Mapping via Approximate Message Passing with Parameter Estimation

Purpose: For quantitative susceptibility mapping (QSM), the lack of ground-truth in clinical settings makes it challenging to determine suitable parameters for the dipole inversion. We propose a probabilistic Bayesian approach for QSM with built-in parameter estimation, and incorporate the nonlinear formulation of the dipole inversion to achieve a robust recovery of the susceptibility maps. Theory: From a Bayesian perspective, the image wavelet coefficients are approximately sparse and modelled by the Laplace distribution. The measurement noise is modelled by a Gaussian-mixture distribution with two components, where the second component is used to model the noise outliers. Through probabilistic inference, the susceptibility map and distribution parameters can be jointly recovered using approximate message passing (AMP). Methods: We compare our proposed AMP with built-in parameter estimation (AMP-PE) to the state-of-the-art L1-QSM, FANSI and MEDI approaches on the simulated and in vivo datasets, and perform experiments to explore the optimal settings of AMP-PE. Reproducible code is available at https://github.com/EmoryCN2L/QSM_AMP_PE Results: On the simulated Sim2Snr1 dataset, AMP-PE achieved the lowest NRMSE, DFCM and the highest SSIM, while MEDI achieved the lowest HFEN. On the in vivo datasets, AMP-PE is robust and successfully recovers the susceptibility maps using the estimated parameters, whereas L1-QSM, FANSI and MEDI typically require additional visual fine-tuning to select or double-check working parameters. Conclusion: AMP-PE provides automatic and adaptive parameter estimation for QSM and avoids the subjectivity from the visual fine-tuning step, making it an excellent choice for the clinical setting.

eess.IV

A Probabilistic Bayesian Approach to Recover $R_2^*$ map and Phase Images for Quantitative Susceptibility Mapping

Purpose: Undersampling is used to reduce the scan time for high-resolution 3D magnetic resonance imaging. In order to achieve better image quality and avoid manual parameter tuning, we propose a probabilistic Bayesian approach to recover $R_2^*$ map and phase images for quantitative susceptibility mapping (QSM), while allowing automatic parameter estimation from undersampled data. Theory: Sparse prior on the wavelet coefficients of images is interpreted from a Bayesian perspective as sparsity-promoting distribution. A novel nonlinear approximate message passing (AMP) framework that incorporates a mono-exponential decay model is proposed. The parameters are treated as unknown variables and jointly estimated with image wavelet coefficients. Results: The proposed AMP with parameter estimation (AMP-PE) approach successfully recovers $R_2^*$ maps and phase images for QSM across various undersampling rates. It is more computationally efficient, and performs better than the state-of-the-art $l_1$-norm regularization (L1) approach in general, except a few cases where the L1 approach performs as well as AMP-PE. Conclusion: AMP-PE achieves better performance by drawing information from both the sparse prior and the mono-exponential decay model. It does not require parameter tuning, and works with a clinical, prospective undersampling scheme where parameter tuning is often impossible or difficult due to the lack of ground-truth image.

eess.IV

Fast Nonconvex $T_2^*$ Mapping Using ADMM

Magnetic resonance (MR)-$T_2^*$ mapping is widely used to study hemorrhage, calcification and iron deposition in various clinical applications, it provides a direct and precise mapping of desired contrast in the tissue. However, the long acquisition time required by conventional 3D high-resolution $T_2^*$ mapping method causes discomfort to patients and introduces motion artifacts to reconstructed images, which limits its wider applicability. In this paper we address this issue by performing $T_2^*$ mapping from undersampled data using compressive sensing (CS). We formulate the reconstruction as a nonconvex problem that can be decomposed into two subproblems. They can be solved either separately via the standard approach or jointly via the alternating direction method of multipliers (ADMM). Compared to previous CS-based approaches that only apply sparse regularization on the spin density $\boldsymbol X_0$ and the relaxation rate $\boldsymbol R_2^*$, our formulation enforces additional sparse priors on the $T_2^*$-weighted images at multiple echoes to improve the reconstruction performance. We performed convergence analysis of the proposed algorithm, evaluated its performance on in vivo data, and studied the effects of different sampling schemes. Experimental results showed that the proposed joint-recovery approach generally outperforms the state-of-the-art method, especially in the low-sampling rate regime, making it a preferred choice to perform fast 3D $T_2^*$ mapping in practice. The framework adopted in this work can be easily extended to other problems arising from MR or other imaging modalities with non-linearly coupled variables.

eess.IV