SearcharxivSearch

arXiv subjects

Jaron Grigat

Publications and source records attributed to Jaron Grigat.

6 recordsLinked to original sources

Doberman: a modular and distributed slow control system for small- to medium-scale experiments

We present Doberman (Detector OBsERving and Monitoring ApplicatioN), a lightweight, modular, and open-source slow control system designed for small-to medium-scale physics experiments. Doberman addresses the gap between heavyweight industrial SCADA frameworks and ad hoc laboratory solutions by providing a flexible software architecture that supports heterogeneous instrumentation, distributed deployment, automated control, and robust alarm handling. The web-based graphical user interface Doberview provides live and continuously updated visualization, configuration, and control of the entire experiment, supporting both routine operation and rapid response to exceptional conditions. Doberman has been deployed and validated in multiple experimental setups, ranging from a remotely operated underground gamma-ray spectrometer to a large, highly instrumented liquid xenon test facility with several hundred monitored quantities. Doberman and Doberview are released under permissive open-source licenses, and the software, documentation, and example device integrations are publicly available.

physics.ins-det

Operating a large-diameter dual-phase liquid xenon TPC in the unshielded PANCAKE facility

Future liquid-xenon (LXe) based observatories for rare processes, such as XLZD, require testing of large components and sub-assemblies in cryogenic liquid or gaseous xenon environments. Here we present results from the stable operation of a shallow dual-phase LXe TPC with an inner diameter of 133.4\,cm and a height of 3.1\,cm in the unshielded PANCAKE platform, without underground suppression of cosmic-ray backgrounds. A total of 340\,kg of xenon was used in the experiment, of which 127\,kg constituted the active TPC mass. Measurements of the LXe purity-dependent electron lifetime and the electron drift velocity in LXe demonstrate that sensitive measurements to characterize the TPC performance are possible in a high-background environment, even with a very basic PMT-based light detection system. Improving this will straightforwardly reduce the TPC threshold, which was observed to be around 15\,keV for electronic recoils in TPC operation.

physics.ins-det

PANCAKE: a large-diameter cryogenic test platform with a flat floor for next generation multi-tonne liquid xenon detectors

The PANCAKE facility is the world's largest liquid xenon test platform. Inside its cryostat with an internal diameter of 2.75 m, components for the next generation of liquid xenon experiments, such as DARWIN or XLZD, will be tested at their full scale. This is essential to ensure their successful operation. This work describes the facility, including its cryostat, cooling systems, xenon handling infrastructure, and its monitoring and instrumentation. The inner vessel has a flat floor, which allows the full diameter to be used with a modest amount of xenon. This is a novel approach for such a large cryostat and is of interest for future large-scale experiments, where a standard torispherical head would require tonnes of additional xenon. Our current xenon inventory of 400 kg allows a liquid depth of about 2 cm in the inner cryostat vessel. We also describe the commissioning of the facility, which is now ready for component testing.

physics.ins-det

The XeBRA platform for liquid xenon time projection chamber development

XeBRA is a flexible cryogenic platform designed to perform research and development for liquid xenon detectors searching for rare events. Its extra-large outer cryostat makes it possible to install a wide variety of detector designs. We present the system, including its cryogenic, gas handling, data acquisition and slow control subsystems. Two dual phase time projection chambers with sensitive masses at the 1 kg scale have so far been operated in XeBRA. Using data from these, we determine the field-dependence of the electron drift velocity in liquid xenon. We also measure the relative charge and light yields for 41.5 keV energy deposits from Kr-83m with electric drift fields between 50 V/cm and 677 V/cm.

physics.ins-det

Reduction of $^{222}$Rn-induced Backgrounds in a Hermetic Dual-Phase Xenon Time Projection Chamber

The continuous emanation of $^{222}$Rn from detector surfaces causes the dominant background in current liquid xenon time projection chambers (TPCs) searching for dark matter. A significant reduction is required for the next generation of detectors which are aiming to reach the neutrino floor, such as DARWIN. $^{222}$Rn-induced back\-grounds can be reduced using a hermetic TPC, in which the sensitive target volume is mechanically separated from the rest of the detector containing the majority of Rn-emanating surfaces. We present a hermetic TPC that mainly follows the well-established design of leading xenon TPCs and has been operated successfully over a period of several weeks. By scaling up the results achieved to the DARWIN-scale, we show that the hermetic TPC concept can reduce the $^{222}$Rn concentration to the required level, even with imperfect separation of the volumes.

physics.ins-det

GeMSE: a Low-Background Facility for Gamma-Spectrometry at Moderate Rock Overburden

The GeMSE (Germanium Material and meteorite Screening Experiment) facility operates a low-background HPGe crystal in an underground laboratory with a moderate rock overburden of 620$\,$m.w.e. in Switzerland. It has been optimized for continuous remote operation. A multi-layer passive shielding, a muon veto, and a boil-off nitrogen purge line inside the measurement cavity minimize the instrument's background rate, which decreased by 33% to (164$\pm$2)$\,$counts/day (100-2700$\,$keV) after five years of underground operation. This agrees with the prediction based on the expected decay of short-lived isotopes. A fit to the known background components, modeled via a precise simulation of the detector, shows that the GeMSE background is now muon-dominated. We also present updates towards a more accurate detection efficiency calculation for the screened samples: the thickness of the crystal's outer dead-layer is precisely determined and the efficiency can now be easily calculated for any sample geometry. The advantage of this feature is showcased via the determination of the $^{40}$K content in the screening of a complex-shaped object: a banana.

physics.ins-det