The Effect of Negation on CLIP in Medical Imaging: Limitations of Contrastive Language-Image Pretraining

Large vision-language models like CLIP are increasingly used in medical imaging tasks due to their ability to align images and text without the need for extensive labeled data. This makes them particularly useful for applications like image retrieval, report generation, and classification in clinical settings. A potential issue to this approach is that CLIP-based models often under perform when interpreting negated phrases, which is especially problematic in the context of medical diagnosing. In this study, we evaluate the Stanford AIMI CheXagent model on its ability to correctly retrieve chest X-ray images using prompts with and without negation. The goal of this project is to understand where this model fails and then use it as a base model to improve its retrieval accuracy by fine tuning methods outlined in previous work. Results from this study show improvement in handling of negation in the CLIP model with a slight decrease in accuracy of positive prompt evaluation. Alongside retrieval accuracy, we examined internal model behavior through token attribution, t-SNE projection, and attention-head ablation to better characterize how each fine tuning approach reshaped the text encoders representation of negated clinical language. Through this work, we hope to better understand the internal behavior of CLIP and improve its handling of negation using clinically relevant language for improving its reliability in medical AI devices.

cs.LG

Comparative Study of RF Heating in Deep Brain Stimulation Devices During MRI at 1.5 T and 0.55 T: Challenging the Assumption of Safety at Low Field Strengths

Purpose: Low-field MRI has been assumed to be implant-friendly based on limited studies. However, RF-induced heating due to an implant is a complex resonance phenomenon, highly dependent on the implant's configurations and the applied RF frequencies. This study aims to evaluate the RF heating of DBS implants during MRI at low-field strengths compared to higher field 1.5 T MRI. Methods: A commercial deep brain stimulation (DBS) implant was used in full system as well as lead only configurations to evaluate and compare RF heating during MR imaging at 0.55 T and 1.5 T. The transfer function of the device at both configurations was measured and validated at each of the frequencies, which was then used for the in vivo prediction of RF heating for realistic DBS configurations at head, chest and abdomen imaging landmarks. Results: For the lead only case, the RF heating due to the DBS was substantially smaller during imaging at 0.55 T compared to that at 1.5 T. However, for the full DBS system (longer implant), the RF heating at 0.55 T was comparable to and for some cases even higher than that at 1.5 T, reaching a level that poses risk of tissue damage in patients. Conclusions: While RF heating generally tends to be lower at low-field MRI, the case with longer implanted leads demands extra caution, due to the higher possibility of matching resonant condition at low-field-strength frequencies. Thus, specific risk evaluation for each implant and configuration is required rather than assuming that lower field strength imaging is safer.

physics.med-ph

Open-bore vertical MRI scanners generate significantly less RF heating around deep brain stimulation leads compared to horizontal scanners

Objectives Studies that assess magnetic resonance imaging (MRI) induced radiofrequency (RF) heating of the tissue in the presence of an active electronic implant are mostly performed in horizontal, closed-bore scanners. Vertical, open-bore MRI systems have a 90° rotated magnet and generate a fundamentally different RF field distribution in the body, yet little is known about the RF heating of deep brain stimulation (DBS) systems in this class of scanners. Here, we investigated whether RF heating of DBS devices was significantly different in a vertical, open-bore MRI scanner compared to a horizontal, closed-bore MRI scanner. Materials and Methods In this phantom study, RF heating around the lead of a commercial DBS system implanted in an anthropomorphic phantom was evaluated in a 1.2 T vertical open-bore scanner (Oasis, Fujifilm Healthcare) and a 1.5 T horizontal closed-bore scanner (Aera, Siemens Healthineers). DBS devices were implanted following 30 realistic lead trajectories. Electromagnetic simulations were performed to assess the specific absorption rate (SAR) of RF energy around leads with different internal structures. Results When controlling for B1+rms, temperature increase around the lead-tip was significantly lower at the vertical scanner compared to the horizontal scanner (p-value=9.1x10-7). Electromagnetic simulations demonstrated up to a 14-fold reduction in the maximum 0.1g-averaged SAR deposited in the tissue surrounding the lead-tip in a vertical scanner compared to a horizontal scanner for leads with straight and helical internal wires. Conclusions RF experiments and electromagnetic simulations demonstrated consistently lower RF heating and power deposition around the DBS lead-tip at the vertical scanner compared to the horizontal scanner. Our simulation results suggest that this trend in heating may potentially extend to leads from other manufacturers.

physics.med-ph