SearcharxivSearch

arXiv subjects

Jason P. Y. Cheung

Publications and source records attributed to Jason P. Y. Cheung.

4 recordsLinked to original sources

Error Correction in Radiology Reports: A Knowledge Distillation-Based Multi-Stage Framework

The increasing complexity and workload of clinical radiology leads to inevitable oversights and mistakes in their use as diagnostic tools, causing delayed treatments and sometimes life-threatening harm to patients. While large language models (LLMs) have shown remarkable progress in many tasks, their utilities in detecting and correcting errors in radiology reporting are limited. This paper proposes a novel dual-knowledge infusion framework that enhances LLMs' capability for radiology report proofreading through systematic integration of medical expertise. Specifically, the knowledge infusion combines medical knowledge graph distillation (MKGD) with external knowledge retrieval (EXKR), enabling an effective automated approach in tackling mistakes in radiology reporting. By decomposing the complex proofreading task into three specialized stages of detection, localization, and correction, our method mirrors the systematic review process employed by expert radiologists, ensuring both precision and clinical interpretability. To perform a robust, clinically relevant evaluation, a comprehensive benchmark is also proposed using real-world radiology reports with real-world error patterns, including speech recognition confusions, terminology ambiguities, and template-related inconsistencies. Extensive evaluations across multiple LLM architectures demonstrate substantial improvements of our approach: up to 31.56% increase in error detection accuracy and 37.4% reduction in processing time. Human evaluation by radiologists confirms superior clinical relevance and factual consistency compared to existing approaches.

cs.CL

A Dual-Feature Extractor Framework for Accurate Back Depth and Spine Morphology Estimation from Monocular RGB Images

Scoliosis is a prevalent condition that impacts both physical health and appearance, with adolescent idiopathic scoliosis (AIS) being the most common form. Currently, the main AIS assessment tool, X-rays, poses significant limitations, including radiation exposure and limited accessibility in poor and remote areas. To address this problem, the current solutions are using RGB images to analyze spine morphology. However, RGB images are highly susceptible to environmental factors, such as lighting conditions, compromising model stability and generalizability. Therefore, in this study, we propose a novel pipeline to accurately estimate the depth information of the unclothed back, compensating for the limitations of 2D information, and then estimate spine morphology by integrating both depth and surface information. To capture the subtle depth variations of the back surface with precision, we design an adaptive multiscale feature learning network named Grid-Aware Multiscale Adaptive Network (GAMA-Net). This model uses dual encoders to extract both patch-level and global features, which are then interacted by the Patch-Based Hybrid Attention (PBHA) module. The Adaptive Multiscale Feature Fusion (AMFF) module is used to dynamically fuse information in the decoder. As a result, our depth estimation model achieves remarkable accuracy across three different evaluation metrics, with scores of nearly 78.2%, 93.6%, and 97.5%, respectively. To further validate the effectiveness of the predicted depth, we integrate both surface and depth information for spine morphology estimation. This integrated approach enhances the accuracy of spine curve generation, achieving an impressive performance of up to 97%.

eess.IV

EUFormer: Learning Driven 3D Spine Deformity Assessment with Orthogonal Optical Images

In clinical settings, the screening, diagnosis, and monitoring of adolescent idiopathic scoliosis (AIS) typically involve physical or radiographic examinations. However, physical examinations are subjective, while radiographic examinations expose patients to harmful radiation. Consequently, we propose a pipeline that can accurately determine scoliosis severity. This pipeline utilizes posteroanterior (PA) and lateral (LAT) RGB images as input to generate spine curve maps, which are then used to reconstruct the three-dimensional (3D) spine curve for AIS severity grading. To generate the 2D spine curves accurately and efficiently, we further propose an Efficient U-shape transFormer (EUFormer) as the generator. It can efficiently utilize the learned feature across channels, therefore producing consecutive spine curves from both PA and LAT views. Experimental results demonstrate superior performance of EUFormer on spine curve generation against other classical U-shape models. This finding demonstrates that the proposed method for grading the severity of AIS, based on a 3D spine curve, is more accurate when compared to using a 2D spine curve.

cs.GR

Chain-of-Though (CoT) prompting strategies for medical error detection and correction

This paper describes our submission to the MEDIQA-CORR 2024 shared task for automatically detecting and correcting medical errors in clinical notes. We report results for three methods of few-shot In-Context Learning (ICL) augmented with Chain-of-Thought (CoT) and reason prompts using a large language model (LLM). In the first method, we manually analyse a subset of train and validation dataset to infer three CoT prompts by examining error types in the clinical notes. In the second method, we utilise the training dataset to prompt the LLM to deduce reasons about their correctness or incorrectness. The constructed CoTs and reasons are then augmented with ICL examples to solve the tasks of error detection, span identification, and error correction. Finally, we combine the two methods using a rule-based ensemble method. Across the three sub-tasks, our ensemble method achieves a ranking of 3rd for both sub-task 1 and 2, while securing 7th place in sub-task 3 among all submissions.

cs.CL