SearcharxivSearch

arXiv subjects

Javad Hashemi

Publications and source records attributed to Javad Hashemi.

7 recordsLinked to original sources

Investigating ECG Diagnosis with Ambiguous Labels using Partial Label Learning

Label ambiguity is an inherent and largely unaddressed challenge in real-world electrocardiogram (ECG) diagnosis, arising from overlapping conditions and diagnostic disagreements. However, current ECG models are trained assuming clean and non-ambiguous annotations, limiting both the development and meaningful evaluation of models under real-world conditions. Although Partial Label Learning (PLL) frameworks are designed to learn from ambiguous labels, their effectiveness in medical time-series domains, ECG in particular, remains largely underexplored. We present the first systematic study of PLL methods for ECG diagnosis under both real and controlled ambiguity. First, we adapt nine PLL algorithms to multi-label ECG diagnosis under label ambiguity, and perform detailed evaluations on real clinical settings with multi-annotator diagnostic disagreements. Next, to study PLL effects on ECG in more depth under controlled settings, we introduce a diverse set of clinically motivated synthetic label ambiguities. Our experiments demonstrate that PLL methods vary substantially in robustness across ambiguity types and levels. Moreover, we observe that PLL generally outperforms standard supervised training under label ambiguity, highlighting the value of such frameworks. Through extensive analysis, we identify key limitations of current PLL approaches for clinical settings and outline future directions for developing robust and clinically aligned ambiguity-aware learning frameworks for ECG diagnosis.

cs.LG

Uncertainty-Aware Multi-view Arrhythmia Classification from ECG

We propose a deep neural architecture that performs uncertainty-aware multi-view classification of arrhythmia from ECG. Our method learns two different views (1D and 2D) of single-lead ECG to capture different types of information. We use a fusion technique to reduce the conflict between the different views caused by noise and artifacts in ECG data, thus incorporating uncertainty to obtain stronger final predictions. Our framework contains the following three modules (1) a time-series module to learn the morphological features from ECG; (2) an image-space learning module to learn the spatiotemporal features; and (3) the uncertainty-aware fusion module to fuse the information from the two different views. Experimental results on two real-world datasets demonstrate that our framework not only improves the performance on arrhythmia classification compared to the state-of-the-art but also shows better robustness to noise and artifacts present in ECG.

eess.SP

Dynamic Prototype Rehearsal for Continual ECG Arrhythmia Detection

Continual Learning (CL) methods aim to learn from a sequence of tasks while avoiding the challenge of forgetting previous knowledge. We present DREAM-CL, a novel CL method for ECG arrhythmia detection that introduces dynamic prototype rehearsal memory. DREAM-CL selects representative prototypes by clustering data based on learning behavior during each training session. Within each cluster, we apply a smooth sorting operation that ranks samples by training difficulty, compressing extreme values and removing outliers. The more challenging samples are then chosen as prototypes for the rehearsal memory, ensuring effective knowledge retention across sessions. We evaluate our method on time-incremental, class-incremental, and lead-incremental scenarios using two widely used ECG arrhythmia datasets, Chapman and PTB-XL. The results demonstrate that DREAM-CL outperforms the state-of-the-art in CL for ECG arrhythmia detection. Detailed ablation and sensitivity studies are performed to validate the different design choices of our method.

cs.LG

Subject Representation Learning from EEG using Graph Convolutional Variational Autoencoders

We propose GC-VASE, a graph convolutional-based variational autoencoder that leverages contrastive learning for subject representation learning from EEG data. Our method successfully learns robust subject-specific latent representations using the split-latent space architecture tailored for subject identification. To enhance the model's adaptability to unseen subjects without extensive retraining, we introduce an attention-based adapter network for fine-tuning, which reduces the computational cost of adapting the model to new subjects. Our method significantly outperforms other deep learning approaches, achieving state-of-the-art results with a subject balanced accuracy of 89.81% on the ERP-Core dataset and 70.85% on the SleepEDFx-20 dataset. After subject adaptive fine-tuning using adapters and attention layers, GC-VASE further improves the subject balanced accuracy to 90.31% on ERP-Core. Additionally, we perform a detailed ablation study to highlight the impact of the key components of our method.

eess.SP

In-Distribution and Out-of-Distribution Self-supervised ECG Representation Learning for Arrhythmia Detection

This paper presents a systematic investigation into the effectiveness of Self-Supervised Learning (SSL) methods for Electrocardiogram (ECG) arrhythmia detection. We begin by conducting a novel analysis of the data distributions on three popular ECG-based arrhythmia datasets: PTB-XL, Chapman, and Ribeiro. To the best of our knowledge, our study is the first to quantitatively explore and characterize these distributions in the area. We then perform a comprehensive set of experiments using different augmentations and parameters to evaluate the effectiveness of various SSL methods, namely SimCRL, BYOL, and SwAV, for ECG representation learning, where we observe the best performance achieved by SwAV. Furthermore, our analysis shows that SSL methods achieve highly competitive results to those achieved by supervised state-of-the-art methods. To further assess the performance of these methods on both In-Distribution (ID) and Out-of-Distribution (OOD) ECG data, we conduct cross-dataset training and testing experiments. Our comprehensive experiments show almost identical results when comparing ID and OOD schemes, indicating that SSL techniques can learn highly effective representations that generalize well across different OOD datasets. This finding can have major implications for ECG-based arrhythmia detection. Lastly, to further analyze our results, we perform detailed per-disease studies on the performance of the SSL methods on the three datasets.

cs.LG

Analysis of Augmentations for Contrastive ECG Representation Learning

This paper systematically investigates the effectiveness of various augmentations for contrastive self-supervised learning of electrocardiogram (ECG) signals and identifies the best parameters. The baseline of our proposed self-supervised framework consists of two main parts: the contrastive learning and the downstream task. In the first stage, we train an encoder using a number of augmentations to extract generalizable ECG signal representations. We then freeze the encoder and finetune a few linear layers with different amounts of labelled data for downstream arrhythmia detection. We then experiment with various augmentations techniques and explore a range of parameters. Our experiments are done on PTB-XL, a large and publicly available 12-lead ECG dataset. The results show that applying augmentations in a specific range of complexities works better for self-supervised contrastive learning. For instance, when adding Gaussian noise, a sigma in the range of 0.1 to 0.2 achieves better results, while poor training occurs when the added noise is too small or too large (outside of the specified range). A similar trend is observed with other augmentations, demonstrating the importance of selecting the optimum level of difficulty for the added augmentations, as augmentations that are too simple will not result in effective training, while augmentations that are too difficult will also prevent the model from effective learning of generalized representations. Our work can influence future research on self-supervised contrastive learning on bio-signals and aid in selecting optimum parameters for different augmentations.

eess.SP

Aerosol generation in public restrooms

Aerosolized droplets play a central role in the transmission of various infectious diseases, including Legionnaire's disease, gastroenteritis-causing norovirus, and most recently COVID-19. Respiratory droplets are known to be the most prominent source of transmission for COVID-19, however, alternative routes may exist given the discovery of small numbers of viable viruses in urine and stool samples. Flushing biomatter can lead to the aerosolization of microorganisms, thus, there is a likelihood that bioaerosols generated in public restrooms may pose a concern for the transmission of COVID-19, especially since these areas are relatively confined, experience heavy foot traffic, and may suffer from inadequate ventilation. To quantify the extent of aerosolization, we measure the size and number of droplets generated by flushing toilets and urinals in a public restroom. The results indicate that the particular designs tested in the study generate a large number of droplets in the size range 0.3$μm$ to 3$μm$, which can reach heights of at least 1.52m. Covering the toilet reduced aerosol levels but did not eliminate them completely, suggesting that aerosolized droplets escaped through small gaps between the cover and the seat. In addition to consistent increases in aerosol levels immediately after flushing, there was a notable rise in ambient aerosol levels due to the accumulation of droplets from multiple flushes conducted during the tests. This highlights the need for incorporating adequate ventilation in the design and operation of public spaces, which can help prevent aerosol accumulation in high occupancy areas and mitigate the risk of airborne disease transmission.

physics.flu-dyn