Searcharxiv⌕ Search

arXiv subjects

Jawed Nawabi

Publications and source records attributed to Jawed Nawabi.

6 recordsLinked to original sources

Weight-Space Programming for Medical Imaging: Do We Still Need Training Data?

Can a large language model (LLM) write the parameters of a medical image classifier from medical knowledge alone, without any training data? Such classifiers normally require labelled images, which are costly and often unavailable. We investigate this question through weight-space programming (WSP), in which an LLM writes or adapts the weights and biases of a neural network directly, without optimisation on training data. Claude Opus 5.5 and GPT-6 Astra each generate the parameters of a small LeNet-style CNN in a single reply, without tool use and without access to any image. We compare these networks against zero-shot MedSigLIP and against the same architecture trained on labels using the Adam optimiser, across 7 classification tasks in four modalities: chest X-ray, breast ultrasound and abdominal CT (all from MedMNIST), and pelvic MRI (SynthUterus). The LLM-written networks perform above chance on all six MedMNIST tasks, with a mean test AUC of 0.719 for Opus and 0.711 for Astra. Both models outperform MedSigLIP on 5 of 6 tasks while using more than 10,000 times fewer parameters. However, the same network trained with Adam on only 256 labelled images achieves a higher AUC on every MedMNIST task (mean AUC 0.828). On SynthUterus, Opus attains an AUC of 0.764, whereas Astra falls below chance (AUC 0.136) owing to a systematic error. These results show that LLMs can write functional medical classifiers, but that they do not yet replace training data. We release the protocol, logs and all generated weights at https://github.com/MaximilianLindholz/weight-space-programming-medical.

cs.CV↗

Safeguarding Agentic AI in Radiology Workflows: A Multimodel Evaluation of Rule-based and Large Language Model-based Verification

Purpose: To estimate how often tool-using large language model (LLM) agents record clinically relevant false or unsupported information in simulated radiology documentation and how much safeguards applied before each action reduce these errors. Materials and Methods: In this simulation study (October 2026), 48 synthetic, radiologist-reviewed base scenarios covered finding communication, tumor board preparation and follow-up management. Forty-three also had a misleading-information variant (91 variants). Six LLM agents (Claude Sonnet 5.5, GPT-6.1-Sol, GLM-5.3, MiniMax M3, Gemma-4-31B, Qwen3.8-27B) completed each variant with permissions only, deterministic rules, and rules plus a locally run LLM checker (1638 episodes). The primary outcome was at least one executed high-severity violation per episode. Risk differences were estimated per agent at base-scenario level and, exploratorily, pooled across agents, with analyses of document access and blocks. Results: With permissions only, 7.3%-27.1% of episodes had a high-severity violation (pooled across agents, 19.4%). Pooled, it was 16.7% with rules (-2.8 percentage points; 95% CI: -6.1, 0.5) and 13.2% with rules plus the LLM checker (-6.2; 95% CI: -9.5, -3.0). Adding the LLM checker to rules changed it by -3.5 (95% CI: -6.3, -0.7). No difference between agents was detected (P = .43), and task success did not decrease detectably. In misleading variants, agents opened the altered document in 83% of episodes regardless of error, and 58% of erroneous statements cited it. Most blocked actions (64%-68%) would not have caused a violation and were returned for revision. Conclusion: Layered safeguards reduced but did not prevent high-severity errors. Errors after misleading information reflected misjudged rather than missed information.

cs.AI↗

From Adult Renal Masses to Pediatric Wilms Tumors: Evaluating Cross-Domain Generalization of Kidney Lesion Segmentation on MRI

Deep learning segmentation models for pediatric oncology are often trained on small, single-center cohorts, whereas much larger datasets exist for adult diseases, such as kidney cancer. Whether models trained on adult renal lesions generalize to pediatric Wilms tumors remains unclear. We trained a segmentation model on single-sequence T1- or T2-weighted adult kidney MRI and evaluated it on a held-out adult test set and a pediatric Wilms tumor cohort, where it was compared with a pediatric-specific nnU-Net. Segmentation performance was quantified using the Dice similarity coefficient (DSC) and 95th-percentile Hausdorff distance. On the adult test set, the model achieved a median DSC of 0.86 for renal lesions. On the pediatric cohort, the adult-trained model achieved a median DSC of 0.85 compared with 0.90 for the pediatric-specific model. Despite differences in age, anatomy, and tumor type, the adult-trained model showed promising performance on pediatric Wilms tumors, with only a modest difference in median DSC compared with the pediatric-specific model. However, non-inferiority could not be shown, highlighting the value of pediatric training data. In future work, a fine-tuning strategy could be explored.

cs.CV↗

Autonomous Structuring of Radiology Reports Across Modalities at Archive Scale Using an Open-Weight Large Language Model

Purpose: To develop and evaluate an open-weight large language model (LLM) pipeline that converts an entire archive of free-text radiology reports into structured reports without human oversight. Materials and Methods: In this retrospective study, a pipeline with 150 hierarchically organized templates was developed at one center and tested at a second center on reports from 2010 to 2025. The open-weight model gpt-oss-120B selects the template in three constrained-decoding steps and fills it on one local graphics processing unit. Template selection was scored against expert labels on 914 randomly sampled reports of five modalities, structuring quality on 920 radiography and CT reports corrected field by field by five residents. The pipeline then processed the complete archive of the second center. Proportions are reported with Wilson 95% confidence intervals (CIs). Results: An optimal template set was selected for 74.4% of reports (680 of 914; 95% CI: 71.5%, 77.1%) and an appropriate set for 82.3% (752 of 914; 95% CI: 79.7%, 84.6%), 87.7% for single-region and 54.1% for multi-region reports. Macro semantic textual similarity between output and corrected reference was 0.95 for radiography and 0.97 for CT, residents left 88.7% of 24,638 fields unchanged, and unsupported content was flagged in 1.0% and 1.5% of reports. Of 2,186,982 archive reports, 96.5% received structured output, 2,401,544 structured reports, at 1,258 reports per hour on one graphics processing unit. Conclusion: An open-weight LLM pipeline structured a complete multimodality report archive without human oversight with high content fidelity. Multi-region reports remained the main source of template errors.

cs.AI↗

Robust Renal Mass Segmentation on CT: A Validation Study of an AI-Based Framework

Renal mass segmentation has important potential to enhance the clinical workflow, especially in settings requiring quantitative assessments. Kidney volume could serve as an important biomarker for renal diseases, with changes in volume correlating directly with kidney function. Currently, clinical practice often relies on subjective visual assessment for evaluating kidney size and kidney lesions, including tumors and cysts, which are typically staged based on diameter, volume, and anatomical location. To support a more objective and reproducible approach, this research aims to develop a robust, thoroughly validated renal mass segmentation algorithm, named Renal-Net. We employ publicly available training datasets and leverage the state-of-the-art medical image segmentation framework nnU-Net. Validation is conducted using both proprietary and public test datasets, with segmentation performance quantified by Dice coefficient and the 95th percentile Hausdorff distance. Furthermore, we analyze robustness across subgroups based on patient sex, age, CT contrast phases, and tumor histologic subtypes. Our findings demonstrate that our segmentation algorithm, trained exclusively on publicly available data, generalizes effectively to external test sets and outperforms existing state-of-the-art models across all tested datasets. Subgroup analyses reveal consistent high performance, indicating strong robustness and reliability. The developed algorithm and associated code are publicly accessible at https://github.com/DIAGNijmegen/oncology-kidney-abnormality-segmentation.

cs.CV↗

Benchmarking Foundation Models for Renal Lesion Stratification in CT

The rapid proliferation of open-source medical foundation models (FMs) raises a practical question: how well do their pre-trained representations transfer to clinically relevant but data-scarce classification tasks? Particularly in CT-based renal lesion classification, a push toward greater generalizability would be meaningful, as the field is constrained by inherently limited training data. We addressed this through a benchmark of three medical FMs on this specific task. This six-class problem spans common entities like cysts and clear cell renal cell carcinoma, alongside rare subtypes. Using a frozen feature-probing protocol, we compared FM embeddings against a handcrafted radiomics classifier and a 3D ResNet-50 trained from scratch. Models were trained on a composite dataset of 2,854 lesions and evaluated on an external test set of 234 lesions from The Cancer Imaging Archive. Our results reveal two key findings. First, FM performance (AUC 0.70-0.77) matched the from-scratch ResNet (AUC 0.72) while drastically reducing hardware demand, requiring only seconds on a CPU after feature extraction. However, the conventional radiomics baseline significantly outperformed all deep learning approaches, achieving an AUC of 0.88 (all p $\leq$ 0.002). This suggests that current generalist FM embeddings do not yet capture the fine-grained texture and shape heterogeneity driving histological subtype discrimination. Despite their potential in data-scarce settings, medical FMs did not surpass established models for renal lesion stratification, leaving radiomics as the current state-of-the-art.

cs.CV↗