SearcharxivSearch

arXiv subjects

Jayasai Rajagopal

Publications and source records attributed to Jayasai Rajagopal.

4 recordsLinked to original sources

Task-Based CT Protocol Optimization Using Reinforcement Learning and Virtual Imaging Trials

Protocol optimization in computed tomography (CT) aims to improve diagnostic image quality while reducing radiation dose, but the interdependence of acquisition and reconstruction parameters makes exhaustive testing impractical. We propose a virtual imaging trial framework with reinforcement learning for efficient CT protocol optimization. Sixty-three computational human models with liver lesions were imaged using a validated CT simulator across 468 combinations of acquisition and reconstruction parameters, including tube voltage, tube current, reconstruction kernel, slice thickness, and pixel size. The optimization objective balanced liver lesion detectability, quantified by detectability index d-prime, against radiation dose. A Proximal Policy Optimization agent was trained and conditioned on patient-specific CT localizer embeddings derived from a pretrained vision transformer. On held-out patients, evaluating only 8 protocols per patient, about 2% of exhaustive testing, recovered 98.2% of the exhaustive-search oracle objective. With no patient-specific simulation, surrogate scoring alone achieved 89.7% recovery. Conditioning on the localizer improved zero-simulation recovery by 10.7 percentage points over the localizer-blind policy (paired 95% CI 2.9-19.5; p=0.02). These results show that the proposed framework can substantially reduce exhaustive protocol testing while enabling task-based, dose-aware protocol selection before the diagnostic scan.

cs.CV

Efficient Computing for Medical Image Acquisition and Reconstruction

Medical imaging systems such as CT, MRI, PET, and SPECT do not directly acquire images. Instead, they measure physical signals that encode anatomical or physiological information, and image reconstruction recovers the underlying image by solving an inverse problem. Although these imaging modalities are governed by different imaging physics, they share a common computational framework that naturally connects medical physics, linear algebra, probability, numerical optimization, and efficient computing. As medical imaging systems acquire increasingly large and higher-dimensional datasets, image reconstruction has become one of the primary computational bottlenecks in modern medical imaging. Advanced reconstruction methods, including analytical reconstruction, iterative optimization, and statistical model-based reconstruction, substantially improve image quality while reducing radiation dose or scan time, but at significantly increased computational cost. Efficient computing has therefore become essential for achieving clinically practical reconstruction times. This chapter presents a unified computational perspective on medical image acquisition and reconstruction across CT, MRI, PET, and SPECT. It first reviews the imaging physics and data acquisition process for each modality and derives a generalized mathematical framework for image reconstruction. Building on this framework, the chapter discusses analytical, iterative, and statistical reconstruction methods together with their computational characteristics. Finally, it examines efficient computing considerations, including optimization algorithms, physics-aware forward operators, memory-efficient implementations, and parallel computing strategies. Together, these topics demonstrate how the integration of imaging physics, mathematical modeling, and efficient computing enables accurate and scalable medical image reconstruction.

eess.IV

MASC: Metal-Aware Sampling and Correction via Reinforcement Learning for Accelerated MRI

Metal implants in MRI cause severe artifacts that degrade image quality and hinder clinical diagnosis. Traditional approaches address metal artifact reduction (MAR) and accelerated MRI acquisition as separate problems. We propose MASC, a unified reinforcement learning framework that jointly optimizes metal-aware k-space sampling and artifact correction for accelerated MRI. To enable supervised training, we construct a paired MRI dataset using physics-based simulation, generating k-space data and reconstructions for phantoms with and without metal implants. This paired dataset provides simulated 3D MRI scans with and without metal implants, where each metal-corrupted sample has an exactly matched clean reference, enabling direct supervision for both artifact reduction and acquisition policy learning. We formulate active MRI acquisition as a sequential decision-making problem, where an artifact-aware Proximal Policy Optimization (PPO) agent learns to select k-space phase-encoding lines under a limited acquisition budget. The agent operates on undersampled reconstructions processed through a U-Net-based MAR network, learning patterns that maximize reconstruction quality. We further propose an end-to-end training scheme where the acquisition policy learns to select k-space lines that best support artifact removal while the MAR network simultaneously adapts to the resulting undersampling patterns. Experiments demonstrate that MASC's learned policies outperform conventional sampling strategies, and end-to-end training improves performance compared to using a frozen pre-trained MAR network, validating the benefit of joint optimization. Cross-dataset experiments on FastMRI with physics-based artifact simulation further confirm generalization to realistic clinical MRI data. The code and models of MASC have been made publicly available: https://github.com/hrlblab/masc

cs.CV

Reinforcement Learning-Based Optimization of CT Acquisition and Reconstruction Parameters Through Virtual Imaging Trials

Protocol optimization is critical in Computed Tomography (CT) to achieve high diagnostic image quality while minimizing radiation dose. However, due to the complex interdependencies among CT acquisition and reconstruction parameters, traditional optimization methods rely on exhaustive testing of combinations of these parameters, which is often impractical. This study introduces a novel methodology that combines virtual imaging tools with reinforcement learning to optimize CT protocols more efficiently. Human models with liver lesions were imaged using a validated CT simulator and reconstructed with a novel CT reconstruction toolkit. The optimization parameter space included tube voltage, tube current, reconstruction kernel, slice thickness, and pixel size. The optimization process was performed using a Proximal Policy Optimization (PPO) agent, which was trained to maximize an image quality objective, specifically the detectability index (d') of liver lesions in the reconstructed images. Optimization performance was compared against an exhaustive search performed on a supercomputer. The proposed reinforcement learning approach achieved the global maximum d' across test cases while requiring 79.7% fewer steps than the exhaustive search, demonstrating both accuracy and computational efficiency. The proposed framework is flexible and can accommodate various image quality objectives. The findings highlight the potential of integrating virtual imaging tools with reinforcement learning for CT protocol management.

cs.LG