Back with Weight: Revisiting Very Heavy Ions for Precision Radiotherapy

Accelerated charged particles offer significant physical advantages over X-rays in radiotherapy. In addition to their superior depth-dose distribution, heavy ions provide notable biological benefits compared to protons. Specifically, at therapeutic energies, very heavy ions are expected to exhibit high relative biological effectiveness and a low oxygen enhancement ratio, making them potentially ideal for treating radioresistant tumors. Over fifty years ago, the Lawrence Berkeley Laboratory started a clinical trial to treat cancer patients with particles ranging from helium to argon. However, treatments with ions of atomic number greater than 10 proved highly toxic to normal tissue. Most patients were ultimately treated with helium ions, whose biological effects closely resemble those of protons. In recent years, novel strategies have emerged that can reduce normal tissue toxicity in radiotherapy while preserving tumor control. These advancements open the possibility of revisiting the clinical use of heavier ions. In this paper, we propose that neon ions may serve as an effective modality for treating resistant, hypoxic tumors. Their associated toxicity may be mitigated by employing approaches such as ultra-high dose rate (FLASH) or spatially fractionated radiotherapy. Current plans and prospects for the clinical application of neon ions will be discussed.

physics.med-ph

Multi-Institutional Audit of FLASH and Conventional Dosimetry with a 3D-Printed Anatomically Realistic Mouse Phantom

We conducted a multi-institutional audit of dosimetric variability between FLASH and conventional dose rate (CONV) electron irradiations by using an anatomically realistic 3D-printed mouse phantom. A CT scan of a live mouse was used to create a 3D model of bony anatomy, lungs, and soft tissue. A dual-nozzle 3D printer was used to print the mouse phantom using acrylonitrile butadiene styrene ($~1.02 g/cm^3$) and polylactic acid ($~1.24 g/cm^3$) simultaneously to simulate soft tissue and bone densities, respectively. The lungs were printed separately using lightweight polylactic acid ($~0.64 g/cm^3$). Hounsfield units (HU) and densities were compared with the reference CT scan of the live mouse. Print-to-print reproducibility of the phantom was assessed. Three institutions were each provided a phantom, and each institution performed two replicates of irradiations at selected mouse anatomic regions. The average dose difference between FLASH and CONV dose distributions and deviation from the prescribed dose were measured with radiochromic film. Compared to the reference CT scan, CT scans of the phantom demonstrated mass density differences of $0.10 g/cm^3$ for bone, $0.12 g/cm^3$ for lung, and $0.03 g/cm^3$ for soft tissue regions. Between phantoms, the difference in HU for soft tissue and bone was <10 HU from print to print. Lung exhibited the most variation (54 HU) but minimally affected dose distribution (<0.5% dose differences between phantoms). The mean difference between FLASH and CONV from the first replicate to the second decreased from 4.3% to 1.2%, and the mean difference from the prescribed dose decreased from 3.6% to 2.5% for CONV and 6.4% to 2.7% for FLASH. The framework presented here is promising for credentialing of multi-institutional studies of FLASH preclinical research to maximize the reproducibility of biological findings.

physics.med-ph

Does FLASH deplete Oxygen? Experimental Evaluation for Photons, Protons and Carbon Ions

Purpose: To investigate experimentally, if FLASH irradiation depletes oxygen within water for different radiation types such as photons, protons and carbon ions. Methods: This study presents measurements of the oxygen consumption in sealed, 3D printed water phantoms during irradiation with X-rays, protons and carbon ions at varying dose rates up to 340 Gy/s. The oxygen measurement was performed using an optical sensor allowing for non-invasive measurements. Results: Oxygen consumption in water only depends on dose, dose rate and linear energy transfer (LET) of the irradiation. The total amount of oxygen depleted per 10 Gy was found to be 0.04 - 0.18 % atm for 225 kV photons, 0.04 - 0.25 % atm for 224 MeV protons and 0.09 - 0.17 % atm for carbon ions. consumption depends on dose rate by an inverse power law and saturates for higher dose rates because of self-interactions of radicals. Higher dose rates yield lower oxygen consumption. No total depletion of oxygen was found for clinical doses. Conclusions: FLASH irradiation does consume oxygen, but not enough to deplete all the oxygen present. For higher dose rates, less oxygen was consumed than at standard radiotherapy dose rates. No total depletion was found for any of the analyzed radiation types for 10 Gy dose delivery using FLASH.

physics.med-ph