Evaluation of Silicon-Based Photon-Counting CT for Coronary Stenosis Quantification with Realistic Coronary Artery Phantoms

Objective: To quantify the impact of high-resolution deep silicon photon-counting CT (dSi-PCCT) on coronary stenosis quantification in anatomically realistic calcified coronary artery phantoms using Micro-CT as ground truth. Methods: Twelve vessel sections representing four calcification geometries (Type I-IV) and three luminal iodine concentrations (10, 15, and 20 mg/mL) were scanned under static conditions using energy-integrating detector CT (EID-CT), dSi-PCCT, and Micro-CT. Images were registered to Micro-CT and segmented using an automated threshold-based pipeline. The primary analysis compared longitudinal profiles of Micro-CT-referenced percent area stenosis and segmented vessel area. A secondary analysis evaluated ellipse-derived percent area stenosis and percent vessel-area deviation at the maximum-calcification cross-section. Results: dSi-PCCT reduced whole-profile mean absolute error in Micro-CT-referenced percent area stenosis from 3.10% with EID-CT to 1.62% (p=0.027) and reduced segmented vessel-area error from 0.55 to 0.31 mm2 (p=0.001). In the secondary analysis, absolute deviations in ellipse-derived percent area stenosis ranged from 0.1% to 6.5% for dSi-PCCT and from 0.8% to 24.2% for EID-CT (p<0.001). Mean absolute differences in percent vessel-area deviation from Micro-CT were also lower with dSi-PCCT than with EID-CT (15.0% vs 26.6%, p<0.001). Conclusion: Under static, resolution-optimized conditions, dSi-PCCT improved task-based coronary stenosis quantification and vessel delineation relative to EID-CT, supporting further evaluation in dynamic phantoms and clinical CCTA.

physics.med-ph

Coronary Atherosclerotic Plaque Characterization with Photon-counting CT: a Simulation-based Feasibility Study

Recent development of photon-counting CT (PCCT) brings great opportunities for plaque characterization with much-improved spatial resolution and spectral imaging capability. While existing coronary plaque PCCT imaging results are based on detectors made of CZT or CdTe materials, deep-silicon photon-counting detectors have unique performance characteristics and promise distinct imaging capabilities. In this work, we report a systematic simulation study of a deep-silicon PCCT scanner with a new clinically-relevant digital plaque phantom with realistic geometrical parameters and chemical compositions. This work investigates the effects of spatial resolution, noise, motion artifacts, radiation dose, and spectral characterization. Our simulation results suggest that the deep-silicon PCCT design provides adequate spatial resolution for visualizing a necrotic core and quantitation of key plaque features. Advanced denoising techniques and aggressive bowtie filter designs can keep image noise to acceptable levels at this resolution while keeping radiation dose comparable to that of a conventional CT scan. The ultrahigh resolution of PCCT also means an elevated sensitivity to motion artifacts. It is found that a tolerance of less than 0.4 mm residual movement range requires the application of accurate motion correction methods for best plaque imaging quality with PCCT.

physics.med-ph