SearcharxivSearch

arXiv subjects

Jeffrey Bradley

Publications and source records attributed to Jeffrey Bradley.

3 recordsLinked to original sources

A novel inverse algorithm to solve IPO-IMPT of proton FLASH therapy with sparse filters

Purpose:The recently proposed IPO-IMPT framework allows simultaneous optimization of dose, dose rate, and LET for FLASH treatment planning. Finding solutions to IPO-IMPT is difficult due to computational intensiveness. Nevertheless, an inverse solution that simultaneously specifies the geometry of a sparse filter and weights of a proton intensity map is desirable for both clinical and preclinical applications. Such solutions can reduce effective biological dose to organs at risk in cancer patients as well as reduce the number of animal irradiations needed to derive extra biological dose models in preclinical studies. Methods:Unlike our initial forward heuristic, this inverse IPO-IMPT solution includes simultaneous optimization of sparse range compensation, sparse range modulation, and spot intensity. The daunting computational tasks vital to this endeavor were resolved iteratively with a distributed computing framework to enable Simultaneous Intensity and Energy Modulation and Compensation (SIEMAC). SIEMAC was demonstrated on a human lung cancer patient and a minipig. Results:SIEMAC improves maps of spot intensities and patient-field-specific sparse range compensators and range modulators. For the lung cancer patient, at our max nozzle current of 300 nA, dose rate coverage above 100 Gy/s increased from 57% to 96% in the lung and from 93% to 100% in the heart, and LET coverage above 4 keV/um dropped from 68% to 9% in the lung and from 26% to <1% in the heart. For a simple minipig plan, the FWHM of the dose, dose rate, and LET distributions decreased by 30%, 1.6%, and 57%, respectively, again with similar target dose coverage, thus reducing uncertainty in these quantities for preclinical studies. Conclusion:The inverse solution to IPO-IMPT demonstrated the capability to simultaneously modulate sub-spot proton energy and intensity distributions for clinical and preclinical studies.

physics.med-ph

Deep learning-based Fast Volumetric Image Generation for Image-guided Proton FLASH Radiotherapy

Proton FLASH therapy leverages ultra-high dose-rate radiation to enhance the sparing of organs at risk without compromising tumor control probability. To prepare for the delivery of high doses to targets, we aim to develop a deep learning-based image-guide framework to enable fast volumetric image reconstruction for accurate target localization before FLSAH beam delivery. The proposed framework comprises four modules, including orthogonal kV x-ray projection acquisition, DL-based volumetric image generation, image quality analyses, and water equivalent thickness evaluation. We investigated volumetric image reconstruction using four kV projection pairs with different source angles. Thirty lung patients were identified from the institutional database, and each patient contains a four-dimensional computed tomography dataset with ten respiratory phases. The retrospective patient study indicated that the proposed framework could reconstruct patient volumetric anatomy, including tumors and organs at risk from orthogonal x-ray projections. Considering all evaluation metrics, the kV projections with source angles of 135 and 225 degrees yielded the optimal volumetric images. The proposed framework has been demonstrated to reconstruct volumetric images with accurate lesion locations from two orthogonal x-ray projections. The embedded WET module can be used to detect potential proton beam-specific patient anatomy variations. The framework can deliver fast volumetric image generation and can potentially guide treatment delivery systems for proton FLASH therapy.

physics.med-ph

An Integrated Biological Optimization framework for proton SBRT FLASH treatment planning allows dose, dose rate, and LET optimization using patient-specific ridge filters

Purpose: Patient-specific ridge filters can modulate proton energy to obtain a conformal dose. We describe a new framework for optimization of filter design and spot maps to meet the unique demands of FLASH radiotherapy. We demonstrate an Integrated Biological Optimization IMPT (IBO-IMPT) approach for optimization of dose, dose-averaged dose rate (DADR), and dose-averaged LET (LETd). Methods: We developed inverse planning software to design patient-specific ridge filters that spread the Bragg peak from a fixed-energy, 250 MeV beam to a proximal beam-specific planning target volume. The software optimizes patient-specific ridge filter and uses a Monte Carlo calculation engine, based on Geant4, to provide dose and LET influence matrices. Plan optimization, using matRAD, accommodates the IBO-IMPT objective function considering dose, dose rate, and LET simultaneously with minimum MU constraints. The framework enables design of both regularly spaced and sparse-optimized ridge filters, which allow faster delivery and selective LET optimization. Volume distributions and histograms for dose, DADR, and LETd are compared using evaluation structures specific to the heart and lung. Results: We used IBO-IMPT to design ridge filters for a central lung tumor patient. The IBO-IMPT framework selectively spared heart and lung by reducing LET and increasing dose rate, relative to IMPT planning. Sparse-optimized ridge filters were superior to regularly spaced ridge filters in dose rate. Together, these innovations substantially increased the DADR in the heart and lung while maintaining good target coverage. The volume that received a FLASH dose rate of higher 40 Gy/second increased by 31% for heart and 50% for lung. Conclusion: This proof-of-concept study demonstrates the feasibility of using an IBO-IMPT framework to accomplish proton FLASH SBPT, accounting for dose, DADR, and LETd simultaneously.