SearcharxivSearch

arXiv subjects

Jeffrey H. Lang

Publications and source records attributed to Jeffrey H. Lang.

9 recordsLinked to original sources

Macro-Scale Electrostatic Origami Motor

Origami structures have been an active area of research due to their high volume-to-mass ratio, packability, and shape adaptability. Previously-developed actuated foldable structures have either embedded linear actuators into the structure, or have attached non-folding rotary motors to the exterior structure. Further, in prior work, actuators directly embedded in the structure of folding media all contributed to linear or folding motion, not to continuous rotary motion. On the macro-scale there has not yet been a folding continuous rotary actuator. This paper details the development and testing of the first macro-scale origami rotary motor that can be folded flat, and then unfurled to operate. Using corona discharge for torque production, the prototype motor achieved an expansion ratio of over 3.8:1, reached a top speed of 1720 rpm when driven at -30 kV, and exhibited a maximum motor torque over 0.25 mNm with an active component torque density of 0.11 Nm/kg.

cs.RO

Modeling and Design Optimization of a Linear Motor with Halbach Array for Semiconductor Manufacturing Technology

This paper presents analytical modeling and design of a high-acceleration, low-vibration slotless double-sided linear motor with an arbitrary Halbach array for lithography machines used in semiconductor manufacturing technology. Amperian current and magnetic charge models of permanent magnets are integrated into a hybrid approach to develop comprehensive analytical modeling. Unlike conventional methods that treat magnets as sources for Poisson's equations, the solution is reduced to Laplace's equations, with magnets being represented as boundary conditions. The magnetic fields and potentials within distinct regions, along with machine quantities such as shear stress, force-angle characteristics, torque profile, attraction force, misalignment force, and back-EMF, are derived, comprehensively analyzed, and compared to FEM results for accuracy validation. In addition, two models based on Poisson's equations in terms of scalar and vector potentials are derived, compared, and analyzed. Finally, design optimization and sensitivity analysis of a linear stage for lithography applications are discussed.

eess.SY

An Actuator with Magnetic Restoration, Part I: Electromechanical Model and Identification

Electromechanical models are crucial in the design and control of motors and actuators. Modeling, identification, drive, and current control loop of a limited-rotation actuator with magnetic restoration is presented. New nonlinear and linearized electromechanical models are developed for the design of the drive as well as small and large signal controls of the actuator. To attain a higher accuracy and an efficient design, and the eddy-currents in the laminations and magnet are modeled. This involves analytically solving 1-D and 2-D diffusion equations, leading to the derivation of a lumped-element circuit for system-level analyses, such as control system design. Additionally, the study analyzes and incorporates the impact of pre-sliding friction. The actuator is prototyped, and the paper delves into the identification of the model, presenting a procedure for parameter extraction. A close agreement is observed between the results obtained from the model, finite element analysis, and experimental results. The superiority of the proposed model over previous approaches is highlighted. Part II of the paper is dedicated to the drive circuit, the current control, as well as linear and nonlinear position control system designs.

eess.SY

An Actuator with Magnetic Restoration, Part II: Drive Circuit and Control Loops

In part II, an op-amp-based drive is proposed and designed. Subsequently, a very accurate model for the drive circuit and the current loop is developed as a simulation platform, while its simplified version is derived, tailored for efficient design purposes. Through a comprehensive evaluation, the accuracy and efficacy of both the actuator and drive circuit modeling is scrutinized, showcasing their superiorities over existing approaches. The importance of eddy current modeling is underscored. Also, the effectiveness of the designed current loop and its practical trade-offs are engineered and discussed. Then, three DSP-based position control techniques are implemented: pole placement with voltage drive, pole placement with current drive, and nonlinear control with feed linearization. Both full-order and reduced-order observers are leveraged to estimate the unmeasured states. The performance of control designs across various applications are evaluated through indices such as rise time, overshoot, steady-state error, and large-signal tracking in the step response as well as bandwidth, robustness, phase margin, sensitivity, disturbance rejection, and noise rejection in the frequency domain. The distinctive features of implemented control strategy are compared, offering a nuanced discussion of their respective advantages and drawbacks, shedding light on their potential applications.

eess.SY

An Implantable Piezofilm Middle Ear Microphone: Performance in Human Cadaveric Temporal Bones

Purpose: One of the major reasons that totally implantable cochlear microphones are not readily available is the lack of good implantable microphones. An implantable microphone has the potential to provide a range of benefits over external microphones for cochlear implant users including the filtering ability of the outer ear, cosmetics, and usability in all situations. This paper presents results from experiments in human cadaveric ears of a piezofilm microphone concept under development as a possible component of a future implantable microphone system for use with cochlear implants. This microphone is referred to here as a drum microphone (DrumMic) that senses the robust and predictable motion of the umbo, the tip of the malleus. Methods: The performance was measured of five DrumMics inserted in four different human cadaveric temporal bones. Sensitivity, linearity, bandwidth, and equivalent input noise were measured during these experiments using a sound stimulus and measurement setup. Results: The sensitivity of the DrumMics was found to be tightly clustered across different microphones and ears despite differences in umbo and middle ear anatomy. The DrumMics were shown to behave linearly across a large dynamic range (46 dB SPL to 100 dB SPL) across a wide bandwidth (100 Hz to 8 kHz). The equivalent input noise (0.1-10 kHz) of the DrumMic and amplifier referenced to the ear canal was measured to be 54 dB SPL and estimated to be 46 dB SPL after accounting for the pressure gain of the outer ear. Conclusion: The results demonstrate that the DrumMic behaves robustly across ears and fabrication. The equivalent input noise performance was shown to approach that of commercial hearing aid microphones. To advance this demonstration of the DrumMic concept to a future prototype implantable in humans, work on encapsulation, biocompatibility, connectorization will be required.

eess.AS

The UmboMic: A PVDF Cantilever Microphone

Objective: We present the "UmboMic," a prototype piezoelectric cantilever microphone designed for future use with totally-implantable cochlear implants. Methods: The UmboMic sensor is made from polyvinylidene difluoride (PVDF) because of its low Young's modulus and biocompatibility. The sensor is designed to fit in the middle ear and measure the motion of the underside of the eardrum at the umbo. To maximize its performance, we developed a low noise charge amplifier in tandem with the UmboMic sensor. This paper presents the performance of the UmboMic sensor and amplifier in fresh cadaveric human temporal bones. Results: When tested in human temporal bones, the UmboMic apparatus achieves an equivalent input noise of 32.3 dB SPL over the frequency range 100 Hz to 7 kHz, good linearity, and a flat frequency response to within 10 dB from about 100 Hz to 6 kHz. Conclusion: These results demonstrate the feasibility of a PVDF-based microphone when paired with a low-noise amplifier. The reported UmboMic apparatus is comparable in performance to a conventional hearing aid microphone. Significance: The proof-of-concept UmboMic apparatus is a promising step towards creating a totally-implantable cochlear implant. A completely internal system would enhance the quality of life of cochlear implant users.

eess.AS

Nominality Score Conditioned Time Series Anomaly Detection by Point/Sequential Reconstruction

Time series anomaly detection is challenging due to the complexity and variety of patterns that can occur. One major difficulty arises from modeling time-dependent relationships to find contextual anomalies while maintaining detection accuracy for point anomalies. In this paper, we propose a framework for unsupervised time series anomaly detection that utilizes point-based and sequence-based reconstruction models. The point-based model attempts to quantify point anomalies, and the sequence-based model attempts to quantify both point and contextual anomalies. Under the formulation that the observed time point is a two-stage deviated value from a nominal time point, we introduce a nominality score calculated from the ratio of a combined value of the reconstruction errors. We derive an induced anomaly score by further integrating the nominality score and anomaly score, then theoretically prove the superiority of the induced anomaly score over the original anomaly score under certain conditions. Extensive studies conducted on several public datasets show that the proposed framework outperforms most state-of-the-art baselines for time series anomaly detection.

cs.LG

Precise Fabrication of Uniform Molecular Gaps for Active Nanoscale Devices

Molecules with versatile functionalities and well-defined structures, can serve as building blocks for extreme nanoscale devices. This requires their precise integration into functional heterojunctions, most commonly in the form of metal-molecule-metal architectures. Structural damage and nonuniformities caused by current fabrication techniques, however, limit their effective incorporation. Here, we present a hybrid fabrication approach enabling uniform molecular gaps. Template-stripped lithographically-patterned gold electrodes with sub-nanometer roughness are used as the bottom contacts upon which the molecular layer is formed through self-assembly. The top contacts are assembled using dielectrophoretic trapping of colloidal gold nanorods, resulting in uniform sub-5 nm junctions. In these electrically-active designs, we further explore the possibility of mechanical tunability. The presence of molecules may help control sub-nanometer mechanical modulation which is conventionally difficult to achieve due to instabilities caused by surface adhesive forces. Our approach is versatile, providing a platform to develop and study active molecular gaps towards functional nanodevices.

physics.app-ph

Piezoresistive Foam Sensor Arrays for Marine Applications

Spatially-dense pressure measurements are needed on curved surfaces in marine environments to provide marine vehicles with the detailed, real-time measurements of the near-field flow necessary to improve performance through flow control. To address this challenge, a waterproof and conformal pressure sensor array comprising carbon black-doped-silicone closed-cell foam (CBPDMS foam) was developed for use in marine applications. The response of the CBPDMS foam sensor arrays was characterized using periodic hydrodynamic pressure stimuli from vertical plunging, from which a piecewise polynomial calibration was developed to describe the sensor response. Inspired by the distributed pressure and velocity sensing capabilities of the fish lateral line, the CBPDMS foam sensor arrays have significant advantages over existing commercial sensors for distributed flow reconstruction and control. Experimental results have shown the sensor arrays to have sensitivity on the order of 5 Pascal, dynamic range of 50-500 Pascal; are contained in a waterproof and completely flexible package, and have material cost less than $10 per sensor.

physics.ins-det