SearcharxivSearch

arXiv subjects

Jenny Chen

Publications and source records attributed to Jenny Chen.

9 recordsLinked to original sources

PinFT: Miniature 5-Axis Force/Torque Sensor Embeddable to Tweezer-like Tool

We present PinFT, a miniature five-axis capacitive force/torque sensor designed for direct tip-level integration into tweezer-like tools. The sensor employs a compact three-PCB stack with segmented plated through-hole electrodes and a silicone elastomer dielectric, enabling five-degree-of-freedom force and torque sensing ($F_x$, $F_y$, $F_z$, $T_x$, $T_y$) through displacement of a central 2\,mm-diameter stainless steel pin. The fabricated prototype was calibrated using a higher-order polynomial mapping, yielding mean absolute errors of approximately 0.23\,N for forces and 2.5\,mN$\cdot$m for torques, with coefficients of determination ($R^2$) exceeding 0.97 across all axes. To demonstrate practical utility, a 3D-printed tweezer integrating PinFT sensors at both tips was mounted on a parallel-jaw gripper and evaluated across three representative manipulation tasks: grasping a sub-millimeter SMD capacitor, pulling a simulated hair from a silicone substrate, and tearing a compliant silicone specimen. In all cases, per-tip force sensing reliably captured characteristic force signatures that distinguish successful manipulation from failure events -- including slip and object ejection -- using gradient-based features derived from internal grasp force and net interaction force. These results demonstrate that direct, per-tip force sensing enables standard parallel-jaw grippers to monitor and interpret fine manipulation tasks performed through a handheld tweezer.

cs.RO

Quantization-Aware Distillation for NVFP4 Inference Accuracy Recovery

This technical report presents quantization-aware distillation (QAD) and our best practices for recovering accuracy of NVFP4-quantized large language models (LLMs) and vision-language models (VLMs). QAD distills a full-precision teacher model into a quantized student model using a KL divergence loss. While applying distillation to quantized models is not a new idea, we observe key advantages of QAD for today's LLMs: 1. It shows remarkable effectiveness and stability for models trained through multi-stage post-training pipelines, including supervised fine-tuning (SFT), reinforcement learning (RL), and model merging, where traditional quantization-aware training (QAT) suffers from engineering complexity and training instability; 2. It is robust to data quality and coverage, enabling accuracy recovery without full training data. We evaluate QAD across multiple post-trained models including AceReason Nemotron, Nemotron 3 Nano, Nemotron Nano V2, Nemotron Nano V2 VL (VLM), and Llama Nemotron Super v1, showing consistent recovery to near-BF16 accuracy.

cs.LG

Enhancing optical lattice clock coherence times with erasure conversion

Increasing coherent interrogation times is central to advancing the precision of optical clocks. Synchronous differential optical clock comparisons have now demonstrated atomic coherence times that far exceed the coherence time of the clock laser. While atom coherence times are then primarily limited by errors induced by lattice Raman scattering, excited clock state radiative decay, and broadening from two-body collisions, many of these errors take the atoms out of the clock transition subspace, and can therefore be converted into "erasure" errors if the appropriate readout scheme is employed. Here we experimentally demonstrate a hyperfine-resolved readout technique for ${}^{87}$Sr optical lattice clocks that mitigates decoherence from Raman scattering induced by the lattice as well as radiative decay. By employing hyperfine-resolved readout in synchronous differential comparisons between ${}^{87}$Sr ensembles with both Ramsey and spin echo spectroscopy sequences, we achieve enhanced atomic coherence times exceeding 100 s and 150 s, respectively, enabling longer coherent measurements without a reduction in performance. We anticipate that this hyperfine-resolved readout technique will benefit applications of state-of-the-art optical lattice clock comparisons in which the coherence times are constrained by Raman scattering or radiative decay.

physics.atom-ph

Geometry of the cumulant series in diffusion MRI

Water diffusion gives rise to micron-scale sensitivity of diffusion MRI (dMRI) to cellular-level tissue structure. Precision medicine and quantitative imaging depend on uncovering the information content of dMRI and establishing its parsimonious hardware-independent fingerprint. Based on the rotational SO(3) symmetry, we study the geometry of the dMRI signal and the topology of its acquisition, identify irreducible components and a full set of invariants for the cumulant tensors, and relate them to tissue properties. Including all kurtosis invariants improves multiple sclerosis classification in a cohort of 1189 subjects. We design the shortest acquisitions based on icosahedral vertices to determine the most used invariants in only 1-2 minutes for whole brain. Representing dMRI via scalar invariant maps with definite symmetries will underpin machine learning classifiers of pathology, development, and aging, while fast protocols will enable translation of advanced dMRI into clinic.

physics.med-ph

Mapping tissue microstructure of brain white matter in vivo in health and disease using diffusion MRI

Diffusion magnetic resonance imaging offers unique in vivo sensitivity to tissue microstructure in brain white matter, which undergoes significant changes during development and is compromised in virtually every neurological disorder. Yet, the challenge is to develop biomarkers that are specific to micrometer-scale cellular features in a human MRI scan of a few minutes. Here we quantify the sensitivity and specificity of a multicompartment diffusion modeling framework to the density, orientation and integrity of axons. We demonstrate that using a machine learning based estimator, our biophysical model captures the morphological changes of axons in early development, acute ischemia and multiple sclerosis (total N=821). The methodology of microstructure mapping is widely applicable in clinical settings and in large imaging consortium data to study development, aging and pathology.

physics.med-ph

Optimization and Validation of the DESIGNER dMRI preprocessing pipeline in white matter aging

Various diffusion MRI (dMRI) preprocessing pipelines are currently available to yield more accurate diffusion parameters. Here, we evaluated accuracy and robustness of the optimized Diffusion parameter EStImation with Gibbs and NoisE Removal (DESIGNER) pipeline in a large clinical dMRI dataset and using ground truth phantoms. DESIGNER has been modified to improve denoising and target Gibbs ringing for partial Fourier acquisitions. We compared the revisited DESIGNER (Dv2) (including denoising, Gibbs removal, correction for motion, EPI distortion, and eddy currents) against the original DESIGNER (Dv1) pipeline, minimal preprocessing (including correction for motion, EPI distortion, and eddy currents only), and no preprocessing on a large clinical dMRI dataset of 524 control subjects with ages between 25 and 75 years old. We evaluated the effect of specific processing steps on age correlations in white matter with DTI and DKI metrics. We also evaluated the added effect of minimal Gaussian smoothing to deal with noise and to reduce outliers in parameter maps compared to DESIGNER (Dv2)'s noise removal method. Moreover, DESIGNER (Dv2)'s updated noise and Gibbs removal methods were assessed using ground truth dMRI phantom to evaluate accuracy. Results show age correlation in white matter with DTI and DKI metrics were affected by the preprocessing pipeline, causing systematic differences in absolute parameter values and loss or gain of statistical significance. Both in clinical dMRI and ground truth phantoms, DESIGNER (Dv2) pipeline resulted in the smallest number of outlier voxels and improved accuracy in DTI and DKI metrics as noise was reduced and Gibbs removal was improved. Thus, DESIGNER (Dv2) provides more accurate and robust DTI and DKI parameter maps as compared to no preprocessing or minimal preprocessing.

physics.med-ph

An Observational Study of the Effect of Nike Vaporfly Shoes on Marathon Performance

We collected marathon performance data from a systematic sample of elite and sub-elite athletes over the period 2015 to 2019, then searched the internet for publicly-available photographs of these performances, identifying whether the Nike Vaporfly shoes were worn or not in each performance. Controlling for athlete ability and race difficulty, we estimated the effect on marathon times of wearing the Vaporfly shoes. Assuming that the effect of Vaporfly shoes is additive, we estimate that the Vaporfly shoes improve men's times between 2.0 and 3.9 minutes, while they improve women's times between 0.8 and 3.5 minutes. Assuming that the effect of Vaporfly shoes is multiplicative, we estimate that they improve men's times between 1.4 and 2.8 percent and women's performances between 0.6 and 2.2 percent. The improvements are in comparison to the shoe the athlete was wearing before switching to Vaporfly shoes, and represents an expected improvement rather than a guaranteed improvement.

stat.AP

Data Acquisition and Uesr Interface of Beam Instrumentation System at SRRC

Data acquisition systems for the accelerator complex at SRRC composed various hardware and software components. Beam signals are processed by related processing electronics, and connect to control system by various type of interfaces in data acquisition front-end. These front-end include VME crates, personal computers and instruments bus adapters. Fast Ethernet connected all elements together with control consoles. User interface is running on control console. Real-time data capture; display and alaysis are supported on control console. Analysis tools based on Matlab scripts are adopted. Hardware and software implementation of the system will be presented. User interface supports are also described.

physics.ins-det

Orbit Feedback System for the Storage Ring of SRRC

Orbit feedback system plays crucial roles for the operation of the 3rd generation light source. There are various issues in orbit feedback system should be addressed to achieve ultimate performance. The orbit feedback system in SRRC is upgraded recently to satisfy the requirement of demanding users. Based upon operational experiences of the last few years, new system was designed with more robustness and flexibility. Performance analysis tools are also developed to monitor system performance. Algorithms for feedback control, data acquisition and analysis are described and measurement is also presented.

physics.ins-det