SearcharxivSearch

arXiv subjects

Jeremy Genoud

Publications and source records attributed to Jeremy Genoud.

2 recordsLinked to original sources

Design and First Tests of the Trapped Electrons Experiment T-REX

Gyrotrons are essential for electron cyclotron resonance heating (ECRH) in fusion reactors, making efficient operation crucial for advancing fusion energy. Past experiments revealed instability issues due to trapped electrons in the magnetron injection gun (MIG) region, causing undesired currents and operational failures. To address this, tight manufacturing tolerances are required for the MIG geometry [1]. We present initial findings of the TRapped Electrons eXperiment (T-REX) developed at the Swiss Plasma Center, designed to understand the physics of electron clouds in gyrotron MIGs. T-REX replicates MIG geometries, as well as their typical electric and magnetic fields, and it is supported by 2D Particle-in-Cell (PIC) simulations with the FENNECS code [2, 3]. The setup includes two coaxial electrodes in a vacuum chamber atop a superconducting magnet, with a central electrode biased to negative DC voltages and an outer one at ground, creating a radial electric field (1 to 2 MV/M) and an axial magnetic field (B < 0.4 T). This setup mimics Penning-Malmberg traps. We present the experimental device and first findings on current distribution and also qualitative comparison with FENNECS simulations [4]. Planned diagnostics include optical emission spectroscopy, phosphor screen imaging, Streak camera imaging, and potentially electric field distribution via the Stark effect. This research aims to enhance gyrotron performance and reliability in fusion energy systems.

physics.plasm-ph

Enormous sample scale-up from nanoliter to microliter in high field liquid state dynamic nuclear polarization

Dynamic nuclear polarization (DNP) enhances nuclear magnetic resonance (NMR) signals by transferring electron spin polarization to nuclei. As DNP requires microwave magnetic fields B1 strong enough to saturate electron spins, microwave resonators are generally used to achieve a sufficient B1, at the expense of restricting the sample size. Higher fields improve NMR sensitivity and resolution. However, resonators at 9 T for example can only hold nano-liters (nL). Larger volumes are possible by avoiding resonators, but the higher power needed to reach B1 is likely to evaporate the sample. Here, we demonstrate a breakthrough in liquid state DNP at 9 T, boosting the sample size to the microliter range. We could use high-power (70 W) microwaves thanks to a planar probe designed to alleviate dielectric heating. We enhanced the 1H NMR signal intensity of 2 uL of liquid water by a factor of 14, while maintaining the water temperature below 40 degree Celsius.

physics.app-ph