Searcharxiv⌕ Search

arXiv subjects

Jeremy M. C. Brown

Publications and source records attributed to Jeremy M. C. Brown.

10 recordsLinked to original sources

Radioactive Source Seeking using Bayesian Optimisation with Movement Penalty

The use of mobile robotics in radioactive source seeking has become an important part of modern radiation-safety practices, supporting timely mitigation of contamination risks and helping protect public health. However, measuring radiation is often time-consuming, rendering traditional gradient-based source-seeking methods less effective due to lower sample efficiency. This paper proposes a sample-efficient Bayesian-Optimisation source-seeking strategy that utilises a heteroscedastic Gaussian process surrogate to balance exploration and exploitation. Excessive inter-sample travel is discouraged through a movement switching cost. The strategy is shown to generate sublinear regret in the source-seeking task, while simulations demonstrate its effectiveness in localising radioactive sources.

physics.app-ph↗

Development and Flight Trial of a UAV-based Gamma Ray and Neutron Detection System for Large-Area Radioactivity Mapping and Source Activity Estimation

Advances in scintillation crystal and Silicon PhotoMultiplier (SiPM) technologies have enabled the development of compact, lightweight, and low-power radiation detectors that are suitable for integration with Unmanned Aerial Vehicles (UAVs). This integration enables efficient and cost-effective large-area radiation monitoring while minimising occupational exposure. In this work, a SiPM-based NaIL scintillation detection payload was developed, characterised, and mounted on a multirotor UAV for gamma ray and neutron source localisation and activity estimation applications. To support these capabilities, an analytic radionuclide detection efficiency model was developed and used to estimate radioactivity on the ground from aerial energy spectrum measurements. The analytic expression for the detection efficiency incorporated physical phenomena, including the branching ratio, detector solid angle, air attenuation, and intrinsic peak efficiency, leading to agreement within 10% of experimental radionuclide detection efficiencies. The UAV-based radiation detection system was physically validated through a controlled indoor live radioactive source demonstration at 1.5 m, 3 m, and 4.5 m flight heights. Using the developed ground-level radioactivity estimation method, Cs-137 and Co-60 sources were successfully localised within 0.5 m, and their activities were estimated with errors on the order of 10% or less.

physics.ins-det↗

Neutron Beam Shaping by Ghost Projection

We present a method to shape a neutron beam and project any specified target image using a single universal patterned mask that is transversely displaced. The method relies on ``ghost projection'', which is a reversed form of classical ghost imaging. A set of sub-mask regions that combine to construct the required beam shape is computed; illumination of each region with the determined exposure time projects the shaped beam. We demonstrate this method experimentally, using the Dingo neutron imaging beamline at the OPAL nuclear research reactor (Australia). The ability to shape a neutron beam ``on demand'' allows selective dose delivery away from sensitive areas of samples, such as in cultural heritage artifacts. It also benefits irradiation techniques, e.g., in testing resilience of electronic components for space and defense technologies or neutron therapies.

physics.med-ph↗

Material Properties of Popular Radiation Detection Scintillator Crystals for Optical Physics Transport Modelling in Geant4

Radiation detection is vital for space, medical imaging, homeland security, and environmental monitoring applications. In the past, the Monte Carlo radiation transport toolkit, Geant4, has been employed to enable the effective development of emerging technologies in these fields. Radiation detectors utilising scintillator crystals have benefited from Geant4; however, Geant4 optical physics parameters for scintillator crystal modelling are sparse. This work outlines scintillator properties for GAGG:Ce, CLLBC:Ce, BGO, NaI:Tl, and CsI:Tl. These properties were implemented in a detailed SiPM-based single-volume scintillation detector simulation platform developed in this work. It was validated by its comparison to experimental measurements. For all five scintillation materials, the platform successfully predicted the spectral features for selected gamma ray emitting isotopes with energies between 30 keV to 2 MeV. The full width half maximum (FWHM) and normalised cross-correlation coefficient (NCCC) between simulated and experimental energy spectra were also compared. The majority of simulated FWHM values reproduced the experimental results within a 2% difference, and the majority of NCCC values demonstrated agreement between the simulated and experimental energy spectra. Discrepancies in these figures of merit were attributed to detector signal processing electronics modelling and geometry approximations within the detector and surrounding experimental environment.

physics.ins-det↗

Simulation of DNA damage using Geant4-DNA: an overview of the "molecularDNA" example application

The scientific community shows a great interest in the study of DNA damage induction, DNA damage repair and the biological effects on cells and cellular systems after exposure to ionizing radiation. Several in-silico methods have been proposed so far to study these mechanisms using Monte Carlo simulations. This study outlines a Geant4-DNA example application, named "molecularDNA", publicly released in the 11.1 version of Geant4 (December 2022). It was developed for novice Geant4 users and requires only a basic understanding of scripting languages to get started. The example currently proposes two different DNA-scale geometries of biological targets, namely "cylinders", and the "human cell". This public version is based on a previous prototype and includes new features such as: the adoption of a new approach for the modeling of the chemical stage (IRT-sync), the use of the Standard DNA Damage (SDD) format to describe radiation-induced DNA damage and upgraded computational tools to estimate DNA damage response. Simulation data in terms of single strand break (SSB) and double strand break (DSB) yields were produced using each of these geometries. The results were compared to the literature, to validate the example, producing less than 5 % difference in all cases.

physics.med-ph↗

Modelling the Response of CLLBC(Ce) and TLYC(Ce) SiPM-Based Radiation Detectors in Mixed Radiation Fields with Geant4

CLLBC(Ce) and TLYC(Ce) are novel scintillation materials capable of measuring mixed gamma ray and neutron radiation fields that have gained significant interest in the areas of space and nuclear safety/security science. To date Geant4, the world's most popular Monte Carlo radiation modelling toolkit, has yet to be effectively used to simulate the full response of these materials when coupled to near ultra-violet Silicon PhotoMultipliers (SiPMs). In this work an experimentally validated Geant4 application has been developed with optimised material composition, optical data tables, and physics transport settings that is able to accurately simulate the response of CLLBC(Ce) and TLYC(Ce) SiPM-based radiation detectors under both gamma ray and neutron irradiation. Experimental benchmarking for five different radioactive sources (Co-60, Cs-137, Eu-152, Am-241, and Cf-252) illustrated that this developed Geant4 application was able to reproduce the position and structure of all major spectral features (full energy gamma ray photo-/neutron capture peaks, X-ray escape photopeaks, Compton edge, Compton backscatter peaks, and Compton plateau) to high level of accuracy.

physics.ins-det↗

Full field X-ray Scatter Tomography

In X-ray imaging, photons are transmitted through and absorbed by the subject, but are also scattered in significant quantities. Previous attempts to use scattered photons for biological imaging used pencil or fan beam illumination. Here we present 3D X-ray Scatter Tomography using full-field illumination. Synchrotron imaging experiments were performed of a phantom and the chest of a juvenile rat. Transmitted and scattered photons were simultaneously imaged with separate cameras; a scientific camera directly downstream of the sample stage, and a pixelated detector with a pinhole imaging system placed at 45${}^\circ$ to the beam axis. We obtained scatter tomogram feature fidelity sufficient for segmentation of the lung and major airways in the rat. The image contrast in scatter tomogram slices approached that of transmission imaging, indicating robustness to the amount of multiple scattering present in our case. This opens the possibility of augmenting full-field 2D imaging systems with additional scatter detectors to obtain complementary modes or to improve the fidelity of existing images without additional dose, potentially leading to single-shot or reduced-angle tomography or overall dose reduction for live animal studies.

physics.med-ph↗

An electromagnetic physics constructor for low energy polarised X-/gamma ray transport in Geant4

The production, application, and/or measurement of polarised X-/gamma rays are key to the fields of synchrotron science and X-/gamma-ray astronomy. The design, development and optimisation of experimental equipment utilised in these fields typically relies on the use of Monte Carlo radiation transport modelling toolkits such as Geant4. In this work the Geant4 "G4LowEPPhysics" electromagnetic physics constructor has been reconfigured to offer a "best set" of electromagnetic physics models for studies exploring the transport of low energy polarised X-/gamma rays. An overview of the physics models implemented in "G4LowEPPhysics", and it's experimental validation against Compton X-ray polarimetry measurements of the BL38B1 beamline at the SPring-8 synchrotron (Sayo, Japan) is reported. "G4LowEPPhysics" is shown to be able to reproduce the experimental results obtained at the BL38B1 beamline (SPring-8) to within a level of accuracy on the same order as Geant4's X-/gamma ray interaction cross-sectional data uncertainty (approximately $\pm$ 5 \%).

physics.comp-ph↗

In-Silico Optimisation of Tileable Philips Digital SiPM Based Thin Monolithic Scintillator Detectors for SPECT Applications

Over the last decade one of the most significant technological advances made in the field of radiation detectors for nuclear medicine was the development of Silicon Photomultipler (SiPM) sensors. At present a only small number of SiPM based radiation detectors for Single Photon Emission Computed Tomography (SPECT) applications have been explored, and even fewer experimental prototypes developed. An in-silico investigation into the optimal design of a Philips DPC3200 SiPM photosensor-based thin monolithic scintillator detector for SPECT applications was undertaken using the Monte Carlo radiation transport modelling toolkit Geant4 version 10.5. The performance of the 20 different SPECT radiation detector configurations, 4 scintillator materials (NaI(Tl), GAGG(Ce), CsI(Tl) and LaBr$_{3}$(Ce)) and 5 thicknesses (1 to 5 mm), were determined through the use of seven figures of merit. It was found that a crystal thickness range of 4 to 5 mm was required for all four materials to ensure acceptable energy resolution, sensitivity and spatial resolution performance with the Philips DPC3200 SiPM. Any thinner than this and the performance of all four materials was found to degrade rapidly due to a high probability of material specific fluorescence x-ray escape after incident gamma/x-ray photoelectric absorption. When factoring in each material's magnetic resonance imaging compatibility, hygroscopy, and cost, it was found that CsI(Tl) represents the most promising material to construct tileable Philips digital SiPM based thin monolithic scintillator detectors for SPECT applications.

physics.ins-det↗

Statistical Image Reconstruction for High-Throughput Thermal Neutron Computed Tomography

Neutron Computed Tomography (CT) is an increasingly utilised non-destructive analysis tool in material science, palaeontology, and cultural heritage. With the development of new neutron imaging facilities (such as DINGO, ANSTO, Australia) new opportunities arise to maximise their performance through the implementation of statistically driven image reconstruction methods which have yet to see wide scale application in neutron transmission tomography. This work outlines the implementation of a convex algorithm statistical image reconstruction framework applicable to the geometry of most neutron tomography instruments with the aim of obtaining similar imaging quality to conventional ramp filtered back-projection via the inverse Radon transform, but using a lower number of measured projections to increase object throughput. Through comparison of the output of these two frameworks using a tomographic scan of a known 3 material cylindrical phantom obtain with the DINGO neutron radiography instrument (ANSTO, Australia), this work illustrates the advantages of statistical image reconstruction techniques over conventional filter back-projection. It was found that the statistical image reconstruction framework was capable of obtaining image estimates of similar quality with respect to filtered back-projection using only 12.5% the number of projections, potentially increasing object throughput at neutron imaging facilities such as DINGO eight-fold.

physics.ins-det↗