Voxel-Matching NORDIC: Non-local patch formation by time-series similarity increases tSNR in high-resolution BOLD fMRI

Submillimeter functional magnetic resonance imaging (fMRI) based on blood-oxygenation-level-dependent (BOLD) signal enables the study of brain function at the submillimeter level, uncovering insights into fine-scale organisations like cortical layers and columns. However, its inherently low contrast-to-noise ratio (CNR) and signal-to-noise ratio (SNR) often limit its reliability and applicability. Noise Reduction with Distribution Corrected Principal Components Analysis (NORDIC PCA) is a locally low-rank denoising algorithm that reduces thermal noise levels in BOLD fMRI in a local patch manner. However, local patches often contain a mixture of signals from multiple tissues that negatively affects the low-rank structure of the patches, which limits the denoising capabilities of the algorithm. We propose an alternative approach for patch formation by gathering similar non-local voxels, dubbed voxel-matching (VM) NORDIC. The results on submillimeter-resolution BOLD fMRI data indicate that VM-NORDIC effectively promotes the low rank of the patches by boosting signal redundancy, allowing for more efficient noise attenuation. Moreover, the method barely affects spatial smoothness due to the non-local voxel selection based on time-series similarity. In particular, VM-NORDIC outperforms standard NORDIC with default local patching (Standard-NORDIC) in terms of temporal SNR (tSNR) (~9-90% larger than Standard-NORDIC; ~23-250% larger than the original) and spatial smoothness estimates (~20% of the smoothness induced by Standard-NORDIC). These improvements are fundamental to improving the validity and precision of fMRI studies at submillimeter resolutions.

physics.med-ph↗

Open-source Pulseq sequences on Philips MRI scanners

Purpose: This work aims to address the limitations faced by researchers in developing and sharing new MRI sequences by implementing an interpreter for the open-source MRI pulse sequence format, Pulseq, on a Philips MRI scanner. Methods: The implementation involved modifying a few source code files to create a Pulseq interpreter for the Philips MRI system. Validation experiments were conducted using simulations and phantom scans performed on a 7T Achieva MRI system. The observed sequence and waveforms were compared to the intended ones, and the gradient waveforms produced by the scanner were verified using a field camera. Image reconstruction was performed using the raw k-space samples acquired from both the native vendor environment and the Pulseq interpreter. Results: The reconstructed images obtained through the Pulseq implementation were found to be comparable to those obtained through the native implementation. The performance of the Pulseq interpreter was assessed by profiling the CPU utilization of the MRI spectrometer, showing minimal resource utilization for certain sequences. Conclusion: The successful implementation of the Pulseq interpreter on the Philips MRI scanner demonstrates the feasibility of utilizing Pulseq sequences on Philips MRI scanners. This provides an open-source platform for MRI sequence development, facilitating collaboration among researchers and accelerating scientific progress in the field of MRI.

physics.med-ph↗