Jessica A. M. Bastiaansen

Publications and source records attributed to Jessica A. M. Bastiaansen.

5 recordsLinked to original sources

Fat-free noncontrast whole-heart CMR with fast and power-optimized off-resonant water excitation pulses

Background: Cardiovascular MRI (CMR) faces challenges due to the interference of bright fat signals in visualizing anatomical structures. Effective fat suppression is crucial when using whole-heart CMR. Conventional methods often fall short due to rapid fat signal recovery and water-selective off-resonant pulses come with tradeoffs between scan time and RF energy deposit. A lipid-insensitive binomial off-resonant (LIBOR) RF pulse is introduced, addressing concerns about RF energy and scan time for CMR at 3T. Methods: A short LIBOR pulse was developed and implemented in a free-breathing respiratory self-navigated whole-heart sequence at 3T. A BORR pulse with matched duration, as well as previously used LIBRE pulses, were implemented and optimized for fat suppression in numerical simulations and validated in healthy subjects (n=3). Whole-heart CMR was performed in healthy subjects (n=5) with all four pulses. The SNR of ventricular blood, skeletal muscle, myocardium, and subcutaneous fat, and the coronary vessel sharpness and length were compared. Results: Experiments validated numerical findings and near homogeneous fat suppression was achieved with all pulses. Comparing the short pulses (1ms), LIBOR reduced the RF power two-fold compared with LIBRE, and three-fold compared with BORR, and LIBOR significantly decreased overall fat SNR. The reduction in RF duration shortened the whole-heart acquisition from 8.5min to 7min. No significant differences in coronary arteries detection and sharpness were found when comparing all four pulses. Conclusion: LIBOR enabled whole-heart CMR under 7 minutes at 3T, with large volume fat signal suppression, while reducing RF power compared with LIBRE and BORR. LIBOR is an excellent candidate to address SAR problems encountered in CMR where fat suppression remains challenging and short RF pulses are required.

physics.med-ph↗

Getting the phase consistent: The importance of phase description in balanced steady-state free precession MRI of multicompartment systems

Purpose: Determine the correct mathematical phase description for balanced steady-state free precession (bSSFP) signals in multicompartment systems. Theory and Methods: Based on published bSSFP signal models, two distinct phase descriptions can be formulated: one predicting the presence and the other predicting the absence of destructive interference effects in multicompartment systems. Numerical simulations of bSSFP signals of water and acetone were performed to evaluate the predictions of these two distinct phase descriptions. For experimental validation, bSSFP profiles were measured at 3T using phase-cycled bSSFP acquisitions performed in a phantom containing mixtures of water and acetone, which replicates a system with two signal components. Localized single voxel MRS was performed at 7T to determine the relative chemical-shift of the acetone-water mixtures. Results: Based on the choice of phase description, the simulated bSSFP profiles of water-acetone mixtures varied significantly, either displaying or lacking destructive interference effects, as predicted theoretically. In phantom experiments, destructive interference was consistently observed in the measured bSSFP profiles of water-acetone mixtures, an observation which excludes the phase description that predicts an absence of destructive interference. The connection between the choice of phase description and predicted observation enables an unambiguous experimental identification of the correct phase description for multicompartment bSSFP profiles, which is consistent with Bloch equations. Conclusion: The study emphasizes that consistent phase descriptions are crucial for accurately describing multi-compartment bSSFP signals, as incorrect phase descriptions result in erroneous predictions.

physics.med-ph↗

Motion-resolved fat-fraction mapping with whole-heart free-running multiecho gre and pilot tone

PURPOSE To develop free-running multi-echo GRE for cardiac- and respiratory-motion-resolved whole-heart fat fraction quantification. METHODS Multi-echo readouts optimized for water-fat separation and quantification were integrated within a non-ECG-triggered free-breathing 3D radial GRE acquisition. Pilot Tone navigation was used to extract cardiac and respiratory motion states. Following a XD-GRASP based image reconstruction of the separate echoes, fat fraction, water fraction, R2star and B0 maps, as well as fat and water images, were generated with a maximum likelihood fitting algorithm using graph cuts. The acquisition, reconstruction and post-processing framework was tested in 10 healthy volunteers at 1.5T and compared to a free-breathing ECG-triggered 5-echo acquisition. RESULTS The acquisition was successfully validated in vivo, with motion compensation achieved over all collected echoes, in both respiratory and cardiac dimensions. Pilot Tone navigation provided respiratory and cardiac signals in good agreement (r=0.954 and r=0.783, respectively) with self-gating signal extraction based on the MR data of the first echo. The framework enabled pericardial fat imaging and quantification across the cardiac cycle, revealing a decrease in apparent FF at systole across volunteers. 3D motion-resolved fat fraction maps showed good correlation with reference ECG-triggered measurements, as well as significant difference in measurements performed with NTE = 4 and NTE = 8 echoes (P < 0.0001 in chest fat and P < 0.01 in pericardial fat). CONCLUSION Volunteer experiments at 1.5T demonstrated the feasibility of a whole-heart free-running fat-fraction mapping technique for cardiac MRI in a 6 min scan time, with a resolution of 2mm3 isotropic.

physics.med-ph↗

Free-running SIMilarity-Based Angiography (SIMBA) for simplified anatomical MR imaging of the heart

Purpose: Whole-heart MRA techniques typically target pre-determined motion states and address cardiac and respiratory dynamics independently. We propose a novel fast reconstruction algorithm, applicable to ungated free-running sequences, that leverages inherent similarities in the acquired data to avoid such physiological constraints. Theory and Methods: The proposed SIMilarity-Based Angiography (SIMBA) method clusters the continuously acquired k-space data in order to find a motion-consistent subset that can be reconstructed into a motion-suppressed whole-heart MRA. Free-running 3D radial datasets from six ferumoxytol-enhanced scans of pediatric cardiac patients and twelve non-contrast scans of healthy volunteers were reconstructed with a non-motion-suppressed regridding of all the acquired data (All Data), our proposed SIMBA method, and a previously published free-running framework (FRF) that uses cardiac and respiratory self-gating and compressed sensing. Images were compared for blood-myocardium interface sharpness, contrast ratio, and visibility of coronary artery ostia. Results: Both the fast SIMBA reconstruction (~20s) and the FRF provided significantly higher blood-myocardium sharpness than All Data (P<0.001). No significant difference was observed among the former two. Significantly higher blood-myocardium contrast ratio was obtained with SIMBA compared to All Data and FRF (P<0.01). More coronary ostia could be visualized with both SIMBA and FRF than with All Data (All Data: 4/36, SIMBA: 30/36, FRF: 33/36, both P<0.001) but no significant difference was found between the first two. Conclusion: The combination of free-running sequences and the fast SIMBA reconstruction, which operates without a priori assumptions related to physiological motion, forms a simple workflow for obtaining whole-heart MRA with sharp anatomical structures.

eess.IV↗

Noncontrast free-breathing respiratory self-navigated coronary artery cardiovascular magnetic resonance angiography at 3 T using lipid insensitive binomial off-resonant excitation (LIBRE)

Robust and homogeneous lipid suppression is mandatory for coronary magnetic resonance angiography (MRA) since coronary arteries are commonly embedded in fat. However, effective large volume lipid suppression becomes challenging when performing radial whole-heart coronary MRA and the problem may even be exacerbated at increasing magnetic field strengths. Incomplete fat suppression also generates artifacts, and may affect advanced motion correction methods. The aim was to evaluate a recently reported lipid insensitive MRI method for self-navigated coronary MRA at 3T. Lipid insensitive binomial off resonant excitation (LIBRE) radiofrequency (RF) excitation pulses were included into a self-navigated 3D radial GRE coronary MRA sequence at 3T. LIBRE was compared against conventional fat saturation (FS) and binomial 1-180°-1 water excitation (WE). First, fat suppression of all techniques was numerically characterized using Matlab and experimentally validated in phantoms and in legs of human volunteers. Subsequently, free-breathing self-navigated coronary MRA was performed using the LIBRE pulse as well as FS and WE in ten volunteers. Results obtained in the simulations were confirmed by the experimental validations as LIBRE enabled near complete fat suppression for 3D radial imaging in vitro and in vivo. For self-navigated whole-heart coronary MRA at 3T, fat SNR was significantly attenuated using LIBRE compared with conventional FS. LIBRE increased the RCA vessel sharpness significantly (37 +/- 9% (LIBRE) vs. 29 +/- 8% (FS) and 30 +/- 8% (WE), both p<0.05) and led to a significant increase in the measured RCA vessel length to (83 +/- 31 mm (LIBRE) vs. 56 +/- 12 mm (FS) and 59 +/- 27 (WE) p<0.05). LIBRE enables robust large volume fat suppression and significantly improves coronary artery image quality at 3T compared to the use of conventional fat suppression and water excitation.

physics.med-ph↗