Searcharxiv⌕ Search

arXiv subjects

Jessica C. Ramella-Roman

Publications and source records attributed to Jessica C. Ramella-Roman.

5 recordsLinked to original sources

Gestational Stage Prediction from Cervical Tissue Analysis Using Imaging Mueller Polarimetry Data

Preterm birth is associated with premature cervical remodeling, yet current clinical assessments cannot detect the underlying microstructural changes in collagen organization. We apply imaging Mueller polarimetry to murine cervical tissue at three gestational stages (early, mid, late) and develop classification methods to predict gestational stage from polarimetric maps. Using Lu-Chipman decomposition, we extract orientation and azimuth local variability maps that capture collagen fiber alignment and disorder. We evaluate two approaches under 20-fold leave-one-out cross-validation: an analytical threshold classifier on mean azimuth local variability, and a lightweight CNN ensemble (approximately 76k parameters) operating on spatially resolved maps. The ensemble achieves 70..0% sample-level accuracy, outperforming the analytical baseline (55.0%), with strong performance on early (71.0%) and late (86.0%) gestation. Spatial prediction maps confirm that classification accuracy is highest in the stroma, where collagen remodeling is most prominent. These results demonstrate that Mueller polarimetry combined with deep learning models can detect gestational collagen remodeling noninvasively, offering a potential pathway toward objective cervical assessment for preterm birth risk.

physics.med-ph↗

Body Fat, Skin Tone, and the Accuracy of Smartwatch Caloric Expenditure Estimates

Smartwatches are widely used to estimate caloric expenditure for weight management, clinical decision making, and public health monitoring. These devices combine photoplethysmography, accelerometry, and proprietary algorithms. However, prior studies report substantial error, and the influence of moderators such as skin tone and body fat percentage (BF) remains underexamined. This study tested whether smartwatch brand, BF, and Fitzpatrick skin type (III to V) predict caloric expenditure error relative to indirect calorimetry. Fifty eight Hispanic adults completed a single laboratory visit including a ten minute recumbent cycling protocol with alternating two minute moderate and vigorous intensity intervals, bracketed by rest and recovery. Participants wore four consumer devices: Apple Watch Series 8, Fitbit Sense 2, Samsung Galaxy Watch 5, and Garmin Forerunner 955. Energy expenditure was measured using a COSMED K5 metabolic system. After device specific data quality filtering, valid participant device pairings ranged from 44 to 52 per brand. One sample tests showed significant mean bias for three devices: Apple, Garmin, and Samsung. Fitbit showed no significant overall bias, although this depended on device specific outlier removal. Mean bias varied by brand, with Garmin and Samsung showing the largest overestimations. Mixed effects models revealed significant effects of device and BF, as well as a device by BF interaction, with physical activity energy expenditure error increasing as adiposity increased. Overall, common smartwatches substantially misestimate caloric expenditure compared with indirect calorimetry. Error varies by brand and worsens with higher body fat, highlighting limitations of current consumer wearables and the need for improved accuracy across diverse body types.

physics.med-ph↗

Machine Learning Model for Complete Reconstruction of Diagnostic Polarimetric Images from partial Mueller polarimetry data

The translation of imaging Mueller polarimetry to clinical practice is often hindered by large footprint and relatively slow acquisition speed of the existing instruments. Using polarization-sensitive camera as a detector may reduce instrument dimensions and allow data streaming at video rate. However, only the first three rows of a complete 4x4 Mueller matrix can be measured. To overcome this hurdle we developed a machine learning approach using sequential neural network algorithm for the reconstruction of missing elements of a Mueller matrix from the measured elements of the first three rows. The algorithm was trained and tested on the dataset of polarimetric images of various excised human tissues (uterine cervix, colon, skin, brain) acquired with two different imaging Mueller polarimeters operating in either reflection (wide-field imaging system) or transmission (microscope) configurations at different wavelengths of 550 nm and 385 nm, respectively. The reconstruction performance was evaluated using various error metrics, all of which confirmed low error values. The execution time of the trained neural network algorithm was about 300 microseconds for a single image pixel. It suggests that a machine learning approach with parallel processing of all image pixels combined with the partial Mueller polarimeter operating at video rate can effectively substitute for the complete Mueller polarimeter and produce accurate maps of depolarization, linear retardance and orientation of the optical axis of biological tissues, which can be used for medical diagnosis in clinical settings.

physics.optics↗

An insertable glucose sensor using a compact and cost-effective phosphorescence lifetime imager and machine learning

Optical continuous glucose monitoring (CGM) systems are emerging for personalized glucose management owing to their lower cost and prolonged durability compared to conventional electrochemical CGMs. Here, we report a computational CGM system, which integrates a biocompatible phosphorescence-based insertable biosensor and a custom-designed phosphorescence lifetime imager (PLI). This compact and cost-effective PLI is designed to capture phosphorescence lifetime images of an insertable sensor through the skin, where the lifetime of the emitted phosphorescence signal is modulated by the local concentration of glucose. Because this phosphorescence signal has a very long lifetime compared to tissue autofluorescence or excitation leakage processes, it completely bypasses these noise sources by measuring the sensor emission over several tens of microseconds after the excitation light is turned off. The lifetime images acquired through the skin are processed by neural network-based models for misalignment-tolerant inference of glucose levels, accurately revealing normal, low (hypoglycemia) and high (hyperglycemia) concentration ranges. Using a 1-mm thick skin phantom mimicking the optical properties of human skin, we performed in vitro testing of the PLI using glucose-spiked samples, yielding 88.8% inference accuracy, also showing resilience to random and unknown misalignments within a lateral distance of ~4.7 mm with respect to the position of the insertable sensor underneath the skin phantom. Furthermore, the PLI accurately identified larger lateral misalignments beyond 5 mm, prompting user intervention for re-alignment. The misalignment-resilient glucose concentration inference capability of this compact and cost-effective phosphorescence lifetime imager makes it an appealing wearable diagnostics tool for real-time tracking of glucose and other biomarkers.

physics.med-ph↗

Time-efficient filtering of polarimetric data by checking physical realizability of experimental Mueller matrices

Imaging Mueller polarimetry has already proved its potential for metrology, remote sensing and biomedicine. The real-time applications of this modality require both video rate image acquisition and fast data post-processing algorithms. First, one must check the physical realizability of the experimental Mueller matrices in order to filter out non-physical data, i.e. to test the positive semi-definiteness of the 4x4 Hermitian coherency matrix calculated from the elements of the corresponding Mueller matrix pixel-wise. For this purpose, we compared the execution time for the calculations of i) eigenvalues, ii) Cholesky decomposition, iii) Sylvester's criterion, and iv) coefficients of the characteristic polynomial of the Hermitian coherency matrix using two different approaches, all calculated for the experimental Mueller matrix images (600 pixels x 700 pixels) of mouse uterine cervix. The calculations were performed using C++ and Julia programming languages. Our results showed the superiority of the algorithm iv), in particular, the version based on the simplification via Pauli matrices, in terms of execution time for our dataset, over other algorithms. The sequential implementation of the latter algorithm on a single core already satisfies the requirements of real-time polarimetric imaging in various domains. This can be further amplified by the proposed parallelization (for example, we achieve a 5-fold speed up on 6 cores).

physics.optics↗