Searcharxiv⌕ Search

arXiv subjects

Jiahang Sha

Publications and source records attributed to Jiahang Sha.

2 recordsLinked to original sources

MedJev: Evaluating Zero-Shot System-One Decision Making in Medicine

System One decision models such as Jev answer structured questions in a single forward pass without generating text, offering fast and computationally efficient clinical decision support. We evaluate MedJev, an open System One model that runs locally on a laptop, across ten medical benchmarks spanning medical knowledge, diagnosis, and patient level prediction using MIMIC IV and MIMIC IV ED. We compare MedJev against zero shot LLM baselines, published GPT results, and supervised models. MedJev achieves accuracies of 72.5 percent on MedQA, 75.4 percent on USMLE, and 80.1 percent on NEJM, approaching published GPT 4 performance while maintaining well calibrated confidence estimates (ECE 0.028 to 0.063). On patient level tasks, MedJev achieves an AUROC of 0.926 for In Hospital Mortality, exceeding XGBoost (0.902), but underperforms supervised models on operational outcomes such as ED Triage Admission (0.745 vs. 0.809). Patient level predictions also exhibit substantial miscalibration (In Hospital Mortality ECE 0.286). We introduce a lightweight, two parameter recalibration method that adapts predictions to local patient populations using 50 to 200 labeled examples, reducing ECE to 0.007. Our findings establish open System One models as a promising zero shot baseline for medical AI, combining competitive predictive performance with low computational cost and efficient local calibration. We release our code and evaluation harness to support future research.

cs.CL↗

HIPNO: Symmetry-Aware Physics-Informed Neural Operators for Noninvasive Hemodynamic Inference

Continuous hemodynamic monitoring guides treatment decisions in surgery and intensive care. However, gold-standard signals are only measured in severe cases due to risks associated with invasive measurement. In this work, we introduce HIPNO (Hemodynamic Inference via Physics-informed Neural Operators) to recover hemodynamic state from ubiquitous, non-invasive signals and expand access to advanced monitoring. HIPNO addresses a problem of scale symmetry in physics-informed hemodynamic inference, where different combinations of flow, resistance, and compliance can generate the same observed pressure. We identify the symmetry group of the observation model and parameterize the network in its quotient space. For the 3-element Windkessel model, the quotient coordinates are the compliance-normalized flow $U=Q/C$, the decay time constant $τ_{WK}=R_2 C$, and the characteristic-impedance coordinate $κ=R_1 C$. Across 945499 intraoperative windows from 2562 patients, HIPNO predicts $τ_{wave}$, a proxy for vascular decay derived from pressure, with 32% lower error on the log scale than a population baseline while preserving mean arterial pressure accuracy. Because vascular decay and flow drive occupy separate coordinates, counterfactual perturbations produce the expected directional responses in at least 90% of windows in almost all prespecified scenarios, a separation unavailable to pressure-only baselines. The coordinates are also used as inputs to a calibration model for monitored cardiac output. Finally, the formulation identifies the external compliance or flow reference required to recover absolute physical scale.

q-bio.QM↗