SearcharxivSearch

arXiv subjects

Jian-Fei Liu

Publications and source records attributed to Jian-Fei Liu.

5 recordsLinked to original sources

Power-efficient ultra-broadband soliton microcombs in resonantly-coupled microresonators

The drive to miniaturize optical frequency combs for practical deployment has spotlighted microresonator solitons as a promising chip-scale candidate. However, these soliton microcombs could be very power-hungry when their span increases, especially with fine comb spacings. As a result, realizing an octave-spanning comb at microwave repetition rates for direct optical-microwave linkage is considered not possible for photonic integration due to the high power requirements. Here, we introduce the concept of resonant-coupling to soliton microcombs to reduce pump consumption significantly. Compared to conventional waveguide-coupled designs, we demonstrate (i) a threefold increase in spectral span for high-power combs and (ii) up to a tenfold reduction in repetition frequency for octave-spanning operation. This configuration is compatible with laser integration and yields reliable, turnkey soliton generation. By eliminating the long-standing pump-power bottleneck, microcombs will soon become readily available for portable optical clocks, massively parallel data links, and field-deployable spectrometers.

physics.optics

Integrated optomechanical ultrasonic sensors with nano-Pascal-level sensitivity

Ultrasonic sensors are widely used for object detection and localization in underwater and biological settings. The operational range and spatial resolution are inherently limited by sensor sensitivity, in which conventional piezoelectric transducers have been overwhelmed by advanced photonic sensors. Here, we demonstrate an optomechanical ultrasonic sensor integrated into a photonic platform, which comprises a suspended SiO2 membrane embedded with a high-Q Si3N4 microring resonator. By exploiting simultaneous optical and mechanical resonances, the sensor achieves a record low noise-equivalent pressure (NEP) of 218 nPa/Hz^1/2 at 289 kHz in air and 9.6 nPa/Hz^1/2 at 52 kHz in water. We demonstrate its versatility through photoacoustic gas spectroscopy in air and underwater ultrasound imaging, achieving a minimum detectable C2H2 concentration of 2.9 ppm (integration time 1 s) and an imaging resolution of 1.89 mm, respectively. Our work represents a significant advancement in compact CMOS-compatible ultrasound sensing, unlocking new possibilities in biomedical imaging, environmental monitoring, industrial testing, and underwater communications.

physics.optics

Compact Turnkey Soliton Microcombs at Microwave Rates via Wafer-Scale Fabrication

Soliton microcombs generated in nonlinear microresonators facilitate the photonic integration of timing, frequency synthesis, and astronomical calibration functionalities. For these applications, low-repetition-rate soliton microcombs are essential as they establish a coherent link between optical and microwave signals. However, the required pump power typically scales with the inverse of the repetition rate, and the device footprint scales with the inverse of square of the repetition rate, rendering low-repetition-rate soliton microcombs challenging to integrate within photonic circuits. This study designs and fabricates silicon nitride microresonators on 4-inch wafers with highly compact form factors. The resonator geometries are engineered from ring to finger and spiral shapes to enhance integration density while attaining quality factors over 10^7. Driven directly by an integrated laser, soliton microcombs with repetition rates below 10 GHz are demonstrated via turnkey initiation. The phase noise performance of the synthesized microwave signals reaches -130 dBc/Hz at 100 kHz offset frequency for 10 GHz carrier frequencies. This work enables the high-density integration of soliton microcombs for chip-based microwave photonics and spectroscopy applications.

physics.optics

Picotesla-sensitivity microcavity optomechanical magnetometry

Cavity optomechanical systems have enabled precision sensing of magnetic fields, by leveraging the optical resonance-enhanced readout and mechanical resonance-enhanced response. Previous studies have successfully achieved scalable and reproducible microcavity optomechanical magnetometry (MCOM) by incorporating Terfenol-D thin films into high-quality ($Q$) factor whispering gallery mode (WGM) microcavities. However, the sensitivity was limited to 585 pT/Hz$^{1/2}$, over 20 times inferior to those using Terfenol-D particles. In this work, we propose and demonstrate a high-sensitivity and scalable MCOM approach by sputtering a FeGaB thin film onto a high-$Q$ SiO$_2$ WGM microdisk. Theoretical studies are conducted to explore the magnetic actuation constant and noise-limited sensitivity by varying the parameters of the FeGaB film and SiO$_2$ microdisk. Multiple magnetometers with different radii are fabricated and characterized. By utilizing a microdisk with a radius of 355 $μ$m and a thickness of 1 $μ$m, along with a FeGaB film with a radius of 330 $μ$m and a thickness of 1.3 $μ$m, we have achieved a remarkable peak sensitivity of 1.68 pT/Hz$^{1/2}$ at 9.52 MHz. This represents a significant improvement of over two orders of magnitude compared with previous studies employing sputtered Terfenol-D film. Notably, the magnetometer operates without a bias magnetic field, thanks to the remarkable soft magnetic properties of the FeGaB film. Furthermore, as a proof-of-concept, we have demonstrated the real-time measurement of a pulsed magnetic field simulating the corona current in a high-voltage transmission line using our developed magnetometer. These high-sensitivity magnetometers hold great potential for various applications, such as magnetic induction tomography and corona current monitoring.

physics.optics

Studies of LL-type 500MHz 5-cell superconducting cavity at SINAP

A low loss (LL) type 500 MHz 5-cell superconducting niobium prototype cavity with large beam aperture has been developed successfully including the optimization, the deep drawing and electron beam welding, the surface treatment and the vertical testing. The performance of the fundamental mode was optimized and the higher order modes were damped by adopting an enlarged beam pipe for propagation. Surface preparation or treatment including mechanical polishing, buffered chemical polishing and high pressure rinsing with ultra-pure water and so on was carried out carefully to promise a perfect inner surface condition. The vertical testing results show that the accelerating voltage higher than 7.5 MV was obtained while the quality factor was better than 1E9 at 4.2 K. No obvious multipacting or field emission was found during the test. However, a quench happened while increasing the field a little higher than 7.5 MV that at present limited the cavity performance.

physics.acc-ph