Searcharxiv⌕ Search

arXiv subjects

Jianglai Liu

Publications and source records attributed to Jianglai Liu.

At least 73 records · Page 4Linked to original sources

Neutron-induced nuclear recoil background in the PandaX-4T experiment

Neutron-induced nuclear recoil background is critical to the dark matter searches in the PandaX-4T liquid xenon experiment. This paper studies the feature of neutron background in liquid xenon and evaluates their contribution in the single scattering nuclear recoil events through three methods. The first method is fully Monte Carlo simulation based. The last two are data-driven methods that also use the multiple scattering signals and high energy signals in the data, respectively. In the PandaX-4T commissioning data with an exposure of 0.63 tonne-year, all these methods give a consistent result that there are $1.15\pm0.57$ neutron-induced background in dark matter signal region within an approximated nuclear recoil energy window between 5 and 100 keV.

hep-ex↗

Study of background from accidental coincidence signals in the PandaX-II experiment

The PandaX-II experiment employed a 580kg liquid xenon detector to search for the interactions between dark matter particles and the target xenon atoms. The accidental coincidences of isolated signals result in a dangerous background which mimic the signature of the dark matter. We performed a detailed study on the accidental coincidence background in PandaX-II, including the possible origin of the isolated signals, the background level and corresponding background suppression method. With a boosted-decision-tree algorithm, the accidental coincidence background is reduced by 70% in the dark matter signal region, thus the sensitivity of dark matter search at PandaX-II is improved.

hep-ex↗

A LN2-based cryogenic system prototype for future PandaX experiment

This paper describes results on R&D of an economical and efficient cryogenic system prototype for future liquid xenon detector. The test module of the prototype has a "cold head" attached to a copper rod, which is specially designed to transport heat loads to a free-boiling liquid nitrogen bath. The performance of the test module and commercial refrigerators is compared. The module with an optimized copper rod has demonstrated more than 1500W cooling power at 178K.The temperature of the "cold head" can be kept stable with an error of 0.02K, its fluctuation is within 0.1K.

physics.ins-det↗

A search for two-component Majorana dark matter in a simplified model using the full exposure data of PandaX-II experiment

In the two-component Majorana dark matter model, one dark matter particle can scatter off the target nuclei, and turn into a slightly heavier component. In the framework of a simplified model with a vector boson mediator, both the tree-level and loop-level processes contribute to the signal in direct detection experiment. In this paper, we report the search results for such dark matter from PandaX-II experiment, using total data of the full 100.7 tonne$\cdot$day exposure. No significant excess is observed, so strong constraints on the combined parameter space of mediator mass and dark matter mass are derived. With the complementary search results from collider experiments, a large range of parameter space can be excluded.

hep-ex↗

Low Radioactive Material Screening and Background Control for the PandaX-4T Experiment

PandaX-4T is a ton-scale dark matter direct detection experiment using a dual-phase TPC technique at the China Jinping Underground Laboratory. Various ultra-low background technologies have been developed and applied to material screening for PandaX-4T, including HPGe gamma spectroscopy, ICP-MS, NAA, radon emanation measurement system, krypton assay station, and alpha detection system. Low background materials were selected to assemble the detector. Surface treatment procedures were investigated to further suppress radioactive background. Combining measured results and Monte Carlo simulation, the total material background rates of PandaX-4T in the energy region of 1-25 keV$\rm{}_{ee}$ are estimated to be (9.9 $\pm$ 1.9) $\times \ 10^{-3}$ mDRU for electron recoil and (2.8 $\pm$ 0.6) $\times \ 10^{-4}$ mDRU for nuclear recoil. In addition, $^{nat}$Kr in the detector is estimated to be <8 ppt.

physics.ins-det↗

A Search for the Cosmic Ray Boosted Sub-GeV Dark Matter at the PandaX-II Experiment

We report a novel search for the cosmic ray boosted dark matter using the 100~tonne$\cdot$day full data set of the PandaX-II detector located at the China Jinping Underground Laboratory. With the extra energy gained from the cosmic rays, sub-GeV dark matter particles can produce visible recoil signals in the detector. The diurnal modulations in rate and energy spectrum are utilized to further enhance the signal sensitivity. Our result excludes the dark matter-nucleon elastic scattering cross section between 10$^{-31}$cm$^{2}$ and 10$^{-28}$cm$^{2}$ for a dark matter masses from 0.1 MeV/$c^2$ to 0.1 GeV/$c^2$, with a large parameter space previously unexplored by experimental collaborations.

hep-ex↗

Snowmass2021 Cosmic Frontier White Paper: Puzzling Excesses in Dark Matter Searches and How to Resolve Them

Intriguing signals with excesses over expected backgrounds have been observed in many astrophysical and terrestrial settings, which could potentially have a dark matter origin. Astrophysical excesses include the Galactic Center GeV gamma-ray excess detected by the Fermi Gamma-Ray Space Telescope, the AMS antiproton and positron excesses, and the 511 and 3.5 keV X-ray lines. Direct detection excesses include the DAMA/LIBRA annual modulation signal, the XENON1T excess, and low-threshold excesses in solid state detectors. We discuss avenues to resolve these excesses, with actions the field can take over the next several years.

hep-ph↗

Readout electronics and data acquisition system of PandaX-4T experiment

PandaX-4T is a dark matter direct detection experiment located in China jinping underground laboratory. The central apparatus is a dual-phase xenon detector containing 4 ton liquid xenon in the sensitive volume, with about 500 photomultipliers instrumented in the top and the bottom of the detector. In this paper we present a completely new system of readout electronics and data acquisition in the PandaX-4T experiment. Compared to the one used in the previous PandaX dark matter experiments, the new system features triggerless readout and higher bandwidth. With triggerless readout, dark matter searches are not affected by the efficiency loss of external triggers. The system records single photelectron signals of the dominant PMTs with an average efficiency of 96\%, and achieves the bandwidth of more than 450 MB/s. The system has been used to successfully acquire data during the commissioning runs of PandaX-4T.

physics.ins-det↗

$\rm ^{83}Rb$/$\rm ^{83m}Kr$ production and cross-section measurement with 3.4 MeV and 20 MeV proton beams

$\rm ^{83m}Kr$, with a short lifetime, is an ideal calibration source for liquid xenon or liquid argon detectors. The $\rm ^{83m}Kr$ isomer can be generated through the decay of $\rm ^{83} Rb$ isotope which is usually produced by proton beams bombarding natural krypton atoms. In this paper, we report a successful production of $\rm ^{83}Rb/^{83m}Kr$ with a proton beam energy of 3.4 MeV, and the first measurement of the production rate with such low energy proton beams. Another production attempt is performed using the newly available 20 MeV proton beam in China, and the measured production rate is consistent with previous measurements. The produced $\rm ^{83m}Kr$ source has been successfully injected into the PandaX-II liquid xenon detector, yielding enough statistics for detector calibration.

nucl-ex↗

A 500 MS/s waveform digitizer for PandaX dark matter experiments

Waveform digitizers are key readout instruments in particle physics experiments. In this paper, we present a waveform digitizer for the PandaX dark matter experiments. It supports both external-trigger readout and triggerless readout, accommodating the needs of low rate full-waveform readout and channel-independent low threshold acquisition, respectively. This digitizer is a 8-channel VME board with a sampling rate of 500 MS/s and 14-bit resolution for each channel. A digitizer system consisting of 72 channels has been tested in situ of the PandaX-4T experiment. We report the system performance with real data.

physics.ins-det↗

Dark Matter Search Results from the PandaX-4T Commissioning Run

We report the first dark matter search results using the commissioning data from PandaX-4T. Using a time projection chamber with 3.7-tonne of liquid xenon target and an exposure of 0.63 tonne$\cdot$year, 1058 candidate events are identified within an approximate nuclear recoil energy window between 5 and 100 keV. No significant excess over background is observed. Our data set a stringent limit to the dark matter-nucleon spin-independent interactions, with a lowest excluded cross section (90% C.L.) of $3.8\times10^{-47} $cm$^2$ at a dark matter mass of 30 GeV/$c^2$.

hep-ex↗

Light yield and field dependence measurement in PandaX-II dual-phase xenon detector

The dual-phase xenon time projection chamber (TPC) is one of the most sensitive detector technology for dark matter direct search, where the energy deposition of incoming particle can be converted into photons and electrons through xenon excitation and ionization. The detector response to signal energy deposition varies significantly with the electric field in liquid xenon. We study the detector's light yield and its dependence on the electric field in the PandaX-II dual-phase detector containing 580~kg liquid xenon in the sensitive volume. From our measurements, the light yield at electric fields from 0~V/cm to 317~V/cm is obtained for energy depositions up to 236~keV.

physics.ins-det↗

A search for solar axions and anomalous neutrino magnetic moment with the complete PandaX-II data

We report a search for new physics signals using the low energy electron recoil events in the complete data set from PandaX-II, in light of the recent event excess reported by XENON1T. The data correspond to a total exposure of 100.7 ton-day with liquid xenon. With robust estimates of the dominant background spectra, we perform sensitive searches on solar axions and neutrinos with enhanced magnetic moment. We find that the axion-electron coupling $g_{Ae}<4.6\times 10^{-12}$ for an axion mass less than $\rm 0.1~keV/c^2$ and the neutrino magnetic moment $μ_ν<4.9\times 10^{-11}μ_{B}$ at 90% confidence level. The observed excess from XENON1T is within our experimental constraints.

hep-ex↗

Unambiguously Resolving the Potential Neutrino Magnetic Moment Signal at Large Liquid Scintillator Detectors

Non-vanishing electromagnetic properties of the neutrinos have been predicted by many theories beyond the Standard Model, and an enhanced neutrino magnetic moment can have profound implications for fundamental physics. The XENON1T experiment recently detected an excess of electron recoil events in the 1-7 keV energy range, which can be compatible with solar neutrino magnetic moment interaction at a most probable value of $μ_ν = 2.1 \times 10^{-11} μ_{\text{B}}$. However, tritium backgrounds and solar axion interaction in this energy window are equally plausible causes. Upcoming multi-tonne noble liquid detectors will test these scenarios more in depth, but will continue to face similar ambiguity. We report a unique capability of future large liquid scintillator detectors to help resolve the potential neutrino magnetic moment scenario. With a liquid scintillator exposure of $O$(100) kton$\cdot$year, a sensitivity of $μ_ν < 10^{-11} μ_{\text{B}}$ can be reached at an energy threshold greater than 40 keV, where no tritium or solar axion events but only neutrino magnetic moment signal is still present.

hep-ex↗

Constraining self-interacting dark matter with the full dataset of PandaX-II

Self-interacting Dark Matter (SIDM) is a leading candidate proposed to solve discrepancies between predictions of the prevailing cold dark matter theory and observations of galaxies. Many SIDM models predict the existence of a light force carrier that mediate strong dark matter self-interactions. If the mediator couples to the standard model particles, it could produce characteristic signals in dark matter direct detection experiments. We report searches for SIDM models with a light mediator using the full dataset of the PandaX-II experiment, based on a total exposure of 132 tonne-days. No significant excess over background is found, and our likelihood analysis leads to a strong upper limit on the dark matter-nucleon coupling strength. We further combine the PandaX-II constraints and those from observations of the light element abundances in the early universe, and show that direct detection and cosmological probes can provide complementary constraints on dark matter models with a light mediator.

hep-ex↗

Horizontal Position Reconstruction in PandaX-II

Dual-phase noble-gas time projection chambers (TPCs) have improved the sensitivities for dark matter direct search in past decades. The capability of TPCs to reconstruct 3-D vertexes of keV scale recoilings is one of the most advantageous features. In this work, we develop two horizontal position reconstruction algorithms for the PandaX-II dark matter search experiment using the dual-phase liquid xenon TPC. Both algorithms are optimized by the $^{83m}$Kr calibration events and use photon distribution of ionization signals among photomultiplier tubes to infer the positions. According to the events coming from the gate electrode, the uncertainties in the horizontal positions are 3.4 mm (3.9 mm) in the analytical (simulation-based) algorithm for an ionization signal with several thousand photon electrons in the center of the TPC

physics.ins-det↗

BambooMC -- A Geant4-based simulation program for the PandaX experiments

The purpose of the PandaX experiments is to search for the possible events resulted from dark matter particles, neutrinoless double beta decay or other rare processes with xenon detectors. Understanding the energy depositions from backgrounds or calibration sources in these detectors is very important. The program of BambooMC is created to perform the Geant4-based Monte Carlo simulation, providing reference information for the experiments. We introduce the design and features of BambooMC in this report. The running of the program depends on a configuration file, which combines different detectors, event generators, physics lists and analysis packs together in one simulation. The program can be easily extended and applied to other experiments.

physics.ins-det↗

Construction and Simulation Bias Study of The Guide Tube Calibration System for JUNO

A Guide Tube Calibration System (GTCS) has been designed for the Jiangmen Underground Neutrino Observatory (JUNO), in order to measure the detector energy response near the outer radius of the active volume. Recently, a prototype system has been constructed and tested, and the calibration algorithm has also been studied to evaluate the risk when the simulation tuning and the error control fail. In this paper, we first report its construction and the performance tests in the lab. Then the influence on the global energy measurement caused by the simulation bias of GTCS is discussed, in order to make sure the algorithm is qualified.

physics.ins-det↗