SearcharxivSearch

arXiv subjects

Jianhan Sun

Publications and source records attributed to Jianhan Sun.

3 recordsLinked to original sources

Sub-50 Picosecond exceptionally Bright Perovskite Scintillation by Unlocking Giant Oscillator Strength

Ultrafast scintillators are indispensable for precise timing in high-energy physics and medical diagnostics. Fundamentally constrained by the trade-off between emission rate and light yield, conventional scintillators remain kinetically trapped in the sub-nanosecond regime, failing to break 50-picosecond limit. Here, we demonstrate a strategy to bypass this limitation by harnessing the coherent radiative acceleration in weakly confined CsPbCl3 perovskite nanocrystals to generate an ultrafast photon burst. This effect originates from the giant oscillator strength, which we unlock by suppressing exciton-phonon scattering at mild cryogenic temperatures. Consequently, our scintillator achieves an unprecedented dominant lifetime of 13.11 ps alongside a high light yield of 21,851 ph/MeV. The resulting prompt photon emission rate more than 100 times higher than that of state-of-the-art ultrafast scintillators. We validate this breakthrough in realistic detection scenarios, achieving a coincidence time resolution of 30.8 ps and accurately resolving 13.5 ps electron bunches and 16.6 ps single-shot gamma-ray pulses. Our findings establish a robust coherent framework for next-generation ultrafast scintillators, pushing extreme radiation diagnostics into the picosecond frontier.

cond-mat.mes-hall

Dependence of the Radical Dynamics on the Beam Temporal Profile in FLASH Radiotherapy

Purpose: This study aims to investigate the impact of the beam temporal profile on the radical dynamics and inter-track interactions of FLASH radiotherapy, supporting parameter optimization for the equipment development and clinical implementation. Methods: MonteCarlo simulations based on the IRT method were performed to analyze the dynamics after irradiation, including single-pulse or multi-pulses irradiation, pulse repetition rate, width and dose. The physicochemical experiments were performed to measure the eaq-lifetimes for validation. The generation and recombination of OH and eaq-radicals were recorded under 6 MeV electron irradiation with varying beam temporal profiles. The radial distributions of the radicals were statistically analyzed, and the corresponding LETd and LETt were calculated. The inter-track interactions were assessed through a mathematical model. Results: The spatial distribution and temporal evolution of radicals were significantly affected by the beam time profiles. Compared with multi-pulses irradiation, single-pulse mode with a width less than 1/10 of the radical lifetime, a repetition interval longer than the radical lifetime, and a dose exceeding 1 Gy/pulse can lead to radicals rapid consumption, reducing the residual content. Instantaneous high dose rates induced radical tracks overlaps. When the single-pulse dose exceeded 1 Gy, the overlap probability approached 100%, aligning with the threshold for radical instantaneous combination. Conclusion: Under a low-duty cycle and high instantaneous dose-rate time profile, the radicals were rapidly consumed through track overlap hence reduced damage to normal tissues, inducing FLASH effect. The optimized time profile can be used to guide the development of equipment and parameter settings in clinical practice to maximize the FLASH effect, such as the laser accelerators and superconducting photocathode guns.

physics.med-ph

Dosimetry study of high repetition rate MeV electron beam from a continuous-wave photocathode gun

DC-SRF-II gun, a high-brightness continuous-wave photocathode gun, has greater potential in electron beam irradiation applications. This paper presents the in-vacuum and in-air irradiation dosimetry study of the high repetition rate electron beam from the DC-SRF-II gun with both Monte Carlo simulations and experiments. Especially, high-dose uniform irradiations with flexible and accurate tuning of dose rate across orders of magnitude are demonstrated. Good stability and repeatability of the doses are also shown. The ultra-wide tuning range and precise control of irradiation time and dose rate are expected to pave the way for innovative applications across a wide range of fields.

physics.acc-ph